Page 1: ...EN Operation and Installation Guide Receiver Gateway D6600 ...

Page 2: ...tallation Guide Trademarks 2 Bosch Security Systems 2 05 4998122704E Trademarks Microsoft Windows Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries ...

Page 3: ...ink Monitoring COM3 through CPU Programmable Output Ports 16 10 0 D6600 Operation 16 10 1 Process Flow 16 10 1 1 Event Database 16 10 1 2 Receiver Handshake and Kiss Off 17 10 1 3 Message Verification 18 10 1 4 Handshake Tone Compatibility 18 10 1 5 Message is Received 18 10 1 6 How Call Groups Work 18 10 1 7 Buzzer Operation 18 10 1 8 Reporting Devices Primary and Secondary 18 10 2 Normal Operati...

Page 4: ...anel Showing Input Output Ports 15 Figure 13 Input Wiring for Reverse Configuration 15 Figure 14 D6600 NetCom System Connection Diagram C900TTL E and Any Control Panel 24 Figure 15 D6600 NetCom System Connection Diagram D9133TTL E and Bosch Control Panels 25 Figure 16 NO DATA RECEIVED Message 25 Figure 17 D6600 System Direct Connect 26 Figure 18 D6600 System Standard Network Automation 26 Tables T...

Page 5: ...or communication formats Table 1 D6600 Supported Communication Formats Acron Super Fast Scancom 4 16 1 5 16 1 6 16 1 Ademco 4 1 Express Scancom 4 24 1 5 24 1 6 24 1 Ademco 4 2 Express Seriee FSK Ademco Contact ID Seriee DTMF Ademco High Speed 4 8 1 SIA ADT SIA Silent Knight FSK0 Caller ID Silent Knight FSK1 CFSK Silent Knight FSK2 Common Formats Silent Knight FSK80 D6500 mode DNIS ANI Telim DSC 4 ...

Page 6: ...15 0 Troubleshooting Guide on page 28 3 Contact Bosch Security Systems 24 Hour Technical Support at 888 886 6189 for assistance if you have a receiver spares package and need to replace a circuit card or module The AC DC Power Supply Module and DC DC Power Supply Module are not field serviceable Contact Bosch Security Systems for service Disconnect power to the receiver before removing the CPU or ...

Page 7: ...Table 4 D6600 Line Cards and Modules Name Model Description Telephone line card D6640 Up to eight line cards can be installed in one D6600 Receiver for up to 32 telephone line connections Telephone line card D6641 Functions like the D6640 Includes improved Public Switched Telephone Network PSTN processing additional memory for future enhancements and single firmware upgrade package CPU card D6610 ...

Page 8: ...2 3 4 Bosch Security Systems Fairport NY USA Input 100 120 220 240V 50 60 Hz 2 5 Amps B A T T E R Y 1 2 4 3 1 Blank plate and location of installed D6672 Serial COM1 Expansion Kit 2 D6615 CPU Terminator Card 3 Card slot covers 4 D6645 Line Terminator Card 3 4 Internal View Figure 3 Receiver Card Placement 8 7 4 3 6 5 9 2 1 1 D6645 or D6645INTL Telephone Line Terminator Card 2 Back plate 3 D6615 CP...

Page 9: ...ent Guide Stabilizes the connection and acts as a guide for connecting the terminator card to the line card 3 Telco Line Jacks Standard telephone lines connect to the RJ11C jacks 4 1 1 D6640 D6641 LED Descriptions The LED is active until the system acknowledges the entire transmission and the telephone line is ready to receive signals Figure 6 D6640 D6641 LED Descriptions OL LF 1 2 3 4 1 2 3 4 1 F...

Page 10: ...lled telephone line terminator cards Figure 7 Removing the top cover of the D6600 1 2 3 To replace a failed terminator card remove the six screws Item 1 Figure 7 Hold the top metal cover of the D6600 and lift it off Item 2 Figure 7 4 Remove the defective card 5 Insert the new card in the same slot by aligning the top and bottom of the terminator card with the card guides in the enclosure Figure 8 ...

Page 11: ...ecessary When the line card is initialized as indicated by a printer report the settings in the line card programming section automatically load into the card 7 Connect telephone lines to the line card 4 1 3 Telephone Line Monitoring Voltage The receiver continuously monitors the telephone line voltage Normal operating voltage ranges from 1 8 VDC to 2 5 VDC Any voltage above 2 5 VDC causes the lin...

Page 12: ...0 for repair or replacement 6 0 Printer Specifications Parallel printer connection Use the DB25 port on the back of the D6600 rear panel to connect to a standard parallel text printer Models Safecom SC9002 Star 300 requires 3 25 in 82 6 mm wide paper 7 0 Installation 7 1 All Installations Install the D6600 Communications Receiver Gateway according to the National Electrical Code NEC NFPA 70 the Na...

Page 13: ...necessary options 11 Ensure that communication formats are correct by having communicators send test reports to each line connected to the receiver 7 6 Rack Mount Instructions Rack mounting hardware is included with the D6600 When mounted in a rack plug the D6600 s AC cord into an outlet inside the rack only if the outlet is wired according to Article 760 of the NEC Rack mounting is required per N...

Page 14: ...play if battery missing when AC power restores 11 5 V above Battery OK 11 5 V to 10 2 V Battery Low Below 10 2 V Battery Bad Battery Missing Table 6 shows the calculations for the standby capacity required by UL when using the D6600 Table 6 Calculating Standby Capacity Required by UL Device Qty Battery Standby Current Total Battery Standby Current UPS Standby Current Total UPS Standby Current D660...

Page 15: ...en You can apply other output sources to the input wiring as long as you follow these guidelines The maximum input voltage allowed without causing damage to the input is 24 VDC For UPS Battery OK restore the input range must be between 0 V and 1 V For UPS Battery Low the input range must be between 3 V and 24 V Because the input state is undefined in the voltage range input voltages between 1 V an...

Page 16: ...rm messages that occur in the D6600 The maximum number of events stored in the database is 20000 If the automation system is not functioning the D6600 does the following When receiving over telephone lines the D6600 stops answering and acknowledging calls at 19500 When receiving over a network the D6600 stops acknowledging incoming events at 19000 because the communication is much faster These lim...

Page 17: ...e to download the event database and save it to the Host PC 1 The default User ID is 6200 and the default password is 6200 2 3 In this example the path is C Program Files D6200 and the name of the file is D6600 04 22 2003 13_27_01 ebf The number immediately following D6600 in the file name is the date the file is created Bosch Security Systems Technical Support can only read the proprietary format...

Page 18: ...m the display Many control panels can transmit multiple messages in the same telephone call Program the receiver to print all multiple message transmissions as a group or print each message on arrival Refer to Report Grouping in the D6600 Program Entry Guide P N 4998122702 for more information As the receiver receives each message and checks the accuracy it sends the kiss off tone so the communica...

Page 19: ...ceiving Sequence 1 An alarm occurs on Zone 3 at subscriber location 456 The user programs Account 456 to report to Line 01 and does not assign Line 01 to report to a call group 2 The OL LED glows green when the receiver answers the call and receives data 3 The primary reporting device s such as external printer or automation computer activates If the external printer is a primary reporting device ...

Page 20: ...ch message D6600 D6600 Continues to browse the events in the buffer CAN D6600 Exits this menu Refer to Section 10 1 1 Event Database on page 16 for more information 10 4 4 Current System Trouble Display D6600 System troubles in the buffer D6600 M E D6600 MENU D6600 D6100 M E D6600 D6600 Browse the system troubles in the buffer CAN D6600 Cancels this menu As you correct system troubles the receiver...

Page 21: ... current Automation event 1 F D6600 2 Enter password D6600 default password 6600 3 D6600 M E 4 2 D6600 5 D6600 M E 10 4 8 Line Test Use this option to test the line operation 1 F D6600 2 Enter password D6600 default password 6600 3 D6600 M E 4 3 D6600 D6600 M E 5 D6600 6 1 D6600 to 3 D6600 2 D6600 Selects the line to test 7 D6600 M E The line disconnects the receiver sends the handshakes and the l...

Page 22: ...ne in trouble or without an operating line card Although it is not mandatory not assigning a line to a call group or when there is only one line in the group 1 min of busy time during a 10 min period results in a Busy Seconds Report If you do not assign a line to a call group displays and printer reports identify the line number instead of the Group number A Line Busy Report shows and prints 10 6 ...

Page 23: ... When pressing CAN during the two way audio session the receiver prompts the operator to enter the line number for stopping the two way audio Ensure the D6600 is not in Menu Mode during this operation The OL LF LED flashes green during the audio session The D6600 prints the audio status on the printer with the physical line number and sends the audio status to the automation firmware with the phys...

Page 24: ...rogram the D6600 Refer to the following documents about network communications and their installation requirements NetCom System Guide P N 4998122712 D9133TTL E Installation Guide P N 4998122717 C900TTL E Installation Guide P N 4998122718 DX4020 Installation Guide P N 49522 D6680 Network Adapter Installation Guide P N 4998138732 DeviceInstaller Operation and Installation Guide P N 4998138688 Figur...

Page 25: ...Data Received Reports 12 1 Description If a message is garbled incorrect checksum or inconsistent message rounds due to a noisy telephone line or other difficulty the receiver withholds the kiss off tone This causes the control panel to retransmit the same message up to four times 12 2 No Data Received The D6600 generates the message shown in Figure 16 if one or more of the following occur Telepho...

Page 26: ...e standard RS 232 that the automation computer can interpret and transmit that data back over the network Some messages might go unacknowledged NACK due to increased network activities This forces NetCom to resend these messages Refer to the D6600 NetCom System Guide P N 4998122712 for complete details on network communications and programming Figure 17 D6600 System Direct Connect 1 2 3 1 Host PC ...

Page 27: ...ordered UL and Factory Mutual central station service standards require constant monitoring of telephone lines 14 5 Proper Ground Connect the receivers to an earth ground not a chassis or electrical ground Measure the resistance of the receiver ground to another ground If the meter reads above 2 Ω check your receiver ground against a third ground If the difference is still greater than 2 Ω ground ...

Page 28: ...rd lights when you swap connecting cords the trouble is with the telephone line Replace the telco line connecting cord If the OL LF LED is still on the trouble might be in the telephone line Report the trouble to the telephone company Line Card OL LF LED steadily glows red Telephone line telephone connecting cord line card or telco terminator is defective Take immediate action if a telephone line ...

Page 29: ...ugh COM8 COM settings do not match In the D6200 under the Settings Menu select COM SETTINGS Confirm all settings match the configuration of the D6600 Host Programming Parameters Menu Item 4 5 Parameters On the D6600 ensure Menu Item 4 5 9 RS 232 Direct Access Permission is set to 1 If upgrading software ensure Menu Item 4 5 7 Software Programming Enable on the D6600 is set to 1 If Software Program...

Page 30: ...1 6 4 2 IP Address 2 or 6 4 3 IP Address 3 If communicating over a WAN the external IP address of the LAN with the PC running the D6200 software must be entered into the D6600 s Menu Items 6 4 1 IP Address 1 6 4 2 IP Address 2 or 6 4 3 IP Address 3 Ensure Menu Item 6 4 5 Network Programming Enable in the D6600 is set to 1 Ensure that the D6200 programming software is set up for TCP IP network conn...

Page 31: ...ion Notice This equipment was tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed according to the instruction manual might cau...

Page 32: ...or Technical Support 888 886 6189 When calling for emergency central station service please tell the operator Receiver Problem Receiver Software Version CPU _______________ Line _______________ D6200 ________________ Line 1 Line 17 Line 2 Line 18 Line 3 Line 19 Line 4 Line 20 Line 5 Line 21 Line 6 Line 22 Line 7 Line 23 Line 8 Line 24 Line 9 Line 25 Line 10 Line 26 Line 11 Line 27 Line 12 Line 28 ...

Page 33: ...D6600 Operation and Installation Guide Notes17 0 Service Information Bosch Security Systems 2 05 4998122704E 33 Notes ...

Page 34: ...D6600 Operation and Installation Guide Notes 34 Bosch Security Systems 2 05 4998122704E Notes ...

Page 35: ...D6600 Operation and Installation Guide Notes17 0 Service Information Bosch Security Systems 2 05 4998122704E 35 Notes ...

Page 36: ... 2005 Bosch Security Systems 4998122704E Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...