CM704B

8/16 Zone Expander Module

Security System

Installer Reference Guide

EN

Security Systems

Summary of Contents for CM704B

Page 1: ...CM704B 8 16 Zone Expander Module Security System Installer Reference Guide EN Security Systems ...

Page 2: ...he supplied shunt to the tamper input pins To assist with installation the module includes indicators to show Module and Zone Power status at all times A four way dip switch is used to select the zone expander modules address The address setting determines the zone numbers for each expander as shown in Table 2 and Table 3 on page 4 You should consult these tables before you begin zone programming ...

Page 3: ...ones If an RF receiver has been installed then all zones up to the maximum number supported by the panel become avail able for use as RF zones An RF zone can be assigned or mapped to any spare zone input allowing zone parameters to be programmed Assigning an RF zone to a physical zone will override or ignore the hard wired zones physical input terminals For example if zone 7 is configured as an RF...

Page 4: ...bers Alarm Tamper Zone Numbers Split EOL SW1 SW2 SW3 SW4 Solution 144 Panel Solution E Panel Control Panel 1 to 8 1 to 8 1 to 16 1 OFF OFF OFF OFF 17 to 24 17 to 24 17 to 32 2 ON OFF OFF OFF 33 to 40 33 to 40 33 to 48 3 OFF ON OFF OFF 49 to 56 49 to 56 49 to 64 4 ON ON OFF OFF 65 to 72 65 to 72 65 to 80 5 OFF OFF ON OFF 81 to 88 81 to 88 81 to 96 6 ON OFF ON OFF 97 to 104 97 to 104 97 to 112 7 OFF...

Page 5: ...se of an external power supply CM720B or CM723B is recommended See the Installer Refer ence Guide for more information on available current and wiring options To power the module and sensors etc from an external power supply CM720B or CM723B connect the wiring as shown In this situation the LAN terminal of the module is connected to the external power supply CM720B or similar and must NOT be conne...

Page 6: ...sors etc Five individual output power terminals are provided on the CM704B Expander Zone Power LED lights to show that Zone power is present on terminals and not overloaded LAN Termination Shunt Only fit the shunt if this module is one of the two modules furthest from the Control Panel See Figure 2 and Figure 3 on page 5 for the LAN Power wiring instructions Figure 4 CM704B Connection Diagram REV ...

Page 7: ...notice The Solution 144 and Solution E panels also support the CM705B Universal Expander Modules The CM705B is like having 1 x CM704B zone expander 1 x CM710B output expander and 1 x CM720B power supply module all in one and as such each universal expander added to the system will consume the address of the corresponding single function module For example if a universal expander is assigned to add...

Page 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2012 Bosch Security Systems CM704BIRG Issue FTR1 6 ...