background image

Conettix Universal Dual Path

Communicator

B465

en

Installation and Operation Manual

Summary of Contents for B465

Page 1: ...Conettix Universal Dual Path Communicator B465 en Installation and Operation Manual ...

Page 2: ......

Page 3: ...Install the cellular plug in communicator module optional 17 4 7 Wiring installation 19 4 7 1 System wiring 19 4 7 2 Control panel to B465 wiring for dialer capture 21 4 7 3 Control panel to dry contact wiring 22 4 7 4 B46 module wiring optional 22 4 7 5 Input loop wiring 23 4 7 6 Output wiring 25 4 7 7 Primary power source wiring 26 4 7 8 D1640 120WI transformer wiring optional 29 4 7 9 12 VDC ba...

Page 4: ...Secondary Receiver 63 7 9 1 Ethernet IP Address Host Name 63 7 9 2 Port Number 64 7 9 3 Ethernet Supervision Time 64 7 9 4 Cellular IP Address Host Name 64 7 9 5 Cellular Supervision Time 64 7 9 6 AES Encryption Key Size 65 7 9 7 AES Encryption Key 65 7 10 Ethernet Setup 65 7 10 1 IPv6 Mode 65 7 10 2 IPv6 DNS Server IP Address 65 7 10 3 Alternate IPv6 DNS Server IP Address 66 7 10 4 IPv6 test addr...

Page 5: ...lts set Trouble Output 74 8 4 Tamper 74 8 4 1 Tamper sends reports 74 8 4 2 Tamper sets Trouble Output 74 8 5 Communication Failure Action 75 8 5 1 Comm Fail sends reports 75 8 5 2 Comm Failure sets Trouble Output 75 8 5 3 Comm Failure removes Line 1 phone voltage 75 8 5 4 Comm Failure removes Line 2 phone voltage 75 8 6 Module Supervision 76 8 6 1 Module Faults send reports 76 8 6 2 Module Faults...

Page 6: ...tem 92 12 Specifications and certifications 94 12 1 Technical specifications 94 12 1 1 B465 power supply specifications 96 12 1 2 Application environment 97 12 1 3 Standby battery requirements and calculations 98 12 1 4 24 VDC Input power requirements 99 12 1 5 Required programming to meet UL 864 100 12 1 6 Required programming to meet ULC S304 102 12 1 7 Required programming to meet ULC S559 102 ...

Page 7: ...ng electrostatic equipment is recommended such as anti static wrist strap ESD damage can range from subtle performance degradation to complete device failure Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications Warning Failure to follow these instructions can result in a failure to init...

Page 8: ...otocol When the central station receiver receives the report it sends back an acknowledgement report to the B465 through the Conettix IP protocol The B465 sends the acknowledgement report to the connected control panel through the simulated PSTN connection This process maintains true end to end security B465 connections Ethernet connects to the network 4 programmable inputs 3 programmable outputs ...

Page 9: ...6 LED cover optional page 16 Insert the plug in communicator into the B465 if required Refer to Install the cellular plug in communicator module optional page 17 Wire the B465 to a compatible control panel Refer to Wiring installation page 19 Wire the relays outputs Power up the system Install a communication program if required Refer to Communications Configure the communication module Verify LED...

Page 10: ...1 and phone line 2 8 ー Cellular carrier network 3 ー B465 Conettix Universal Dual Path Communicator 9 ー Conettix receiver gateway D6100IPv6 shown 4 ー B44x plug in cellular communicator 10 ーConettix receiver gateway D6600 shown 5 ー Ethernet connection RJ 45 cable connection to the LAN WAN 11 ー Monitoring center automation classified per UL 1981 6 ー Internet Cloud 3 1 B465 overview The B465 allows an...

Page 11: ...RNAL ANNUNC X MODULE 1 Y MODULE RELEASE 1 COM 2 3 COM 4 T R PNL LINE 1 C NO OUTPUT 2 BAT NO C NC OUTPUT 1 TRBL TX RX AC PANEL LINE 2 USB ETHERNET 100BASE T LINK COMMUNICATION MODULE 1 3 COM 4 1 COM 2 R Y G B SDI2 Device Bus 24 VDC or 16 5VAC BATTERY PANEL LINE 1 BATTERY AC RX TX SYSTEM TROUBLE INPUTS 2 2 k End of Line Resistors C NO OUTPUT 3 12V AUX COM 16 12 14 T R PNL LINE 2 16 5VAC Figure 3 2 M...

Page 12: ...t relays rated at 30 VDC 0 1 A All three outputs are configurable 13 Heartbeat LED shows the operational status of the B465 14 BATTERY terminals connect a 12 V 7 18 Ah Lead Acid battery The battery is the secondary backup power source for the B465 15 Earth Ground terminal Used for earth ground transient protection and reduced emissions 16 24 VDC or 16 5 VAC terminals connect the primary power supp...

Page 13: ...station receiver The system routes event reports to the primary and secondary destinations using Ethernet or cellular communication depending on configuration 3 4 B46 overview optional The B46 is an optional module that provides external B465 LED and sounder status when installed in a supported enclosure The module has 3 LEDs System Trouble Power and Battery which illuminate through the B46 LED co...

Page 14: ...n and Operation Manual Bosch Security Systems Inc 1 3 2 BOSCH Figure 3 4 B46 LED cover B10 enclosure shown Callout ー Description 1 ー B10 Medium Control Panel Enclosure door closed 2 ー B46 LED cover 3 ーEnclosure lock D101 supplied separately For LED patterns refer to B465 LED status indicators page 80 ...

Page 15: ...unning wire or cabling to reduce wire cable damage 4 2 Mount the enclosure Mount one of the following enclosures in the desired location to meet desired UL requirements B10 Medium Control Panel Enclosure white B10R Medium Control Panel Enclosure red B11 Small Control Panel Enclosure white B11R Small Control Panel Enclosure red D8103 Universal enclosure this enclosure requires the B12 mounting plat...

Page 16: ...e in the enclosure so it lines up with the enclosure door hole 4 3 Insert D101 lock optional Refer to the instructions provided with the D101 for installation Notice Commercial fire requirement The D101 lock is required for commercial fire installations 4 4 Insert B46 LED cover optional The B46 has an LED cover allowing users to view the B465 LED status indications outside the enclosure 1 Punch ou...

Page 17: ... wire Notice Do not use telephone or electrical ground for the earth ground connection Do not connect other control panel terminals to earth ground Caution Avoid electrostatic discharge Always touch the earth ground connection with the icon first before beginning work on the control panel Notice In ground fault enabled systems you might cause a ground fault when connecting a computer to the B465 f...

Page 18: ...gnal If the signal to the plug in cellular module is weak place the antenna on top of a metal surface that has a radius of 10 16 cm 4 in or larger to improve performance TMPR BAT ETHERNET EXTERNAL ANNUNC X MODULE 1 Y MODULE RELEASE 1 COM 2 3 COM 4 T R PNL LINE 1 C NO RELAY 2 16 5VAC NC C NO RELAY 1 TRBL TX RX PWR PANEL LINE 2 USB ETHERNET 100BASE T LINK COMMUNICATION MODULE 1 3 COM 4 1 COM 2 R Y G...

Page 19: ... TROUBLE INPUTS 2 2 k End of Line Resistors C NO RELAY 3 12V AUX COM T R PNL LINE 2 24 VDC or 16 5 VAC 5 4 6 7 8 9 10 1 2 _ BATTERY 3 11 Figure 4 3 System wiring Callout ー Description Callout ー Description 1 ー RJ 45 modular jack for Ethernet IP communications optional 7 ーProgrammable output relays Relay 1 Relay 2 Relay 3 2 ー Connector for External Annunciator connected to optional B46 8 ー12 VDC le...

Page 20: ... Manual Bosch Security Systems Inc Notice For ground fault detection connect the common terminals of the FACP and the B465 Connect the common terminal of the FACP Fire Alarm Control Panel auxiliary power to the common COM terminal of the B465 auxiliary power Do not connect to earth ground on the FACP or the B465 ...

Page 21: ...cted control panel for ULC S559 installations Use 14 24AWG wire to connect the B465 PANEL LINE 1 and PANEL LINE 2 terminals to a fire control panel or intrusion control panel phone line terminals Refer to the following figure for wiring information TMPR BAT ETHERNET EXTERNAL ANNUNC X MODULE 1 Y MODULE RELEASE 1 COM 2 3 COM 4 T R PNL LINE 1 C NO RELAY 2 BATTERY 16 5VAC NC C NO RELAY 1 TRBL TX RX PW...

Page 22: ...INE 1 BATTERY POWER RX TX SYSTEM TROUBLE INPUTS 2 2 k End of Line Resistors C NO RELAY 3 12V AUX COM T R PNL LINE 2 24 VDC or 16 5 VAC 1 FIRE ALARM FIRE SUPERVISORY TROUBLE 2 4 3 5 ZONE INPUT AUX COM 7 8 9 6 Figure 4 5 Panel to dry contact wiring Callout ー Description 1 ー Fire intrusion control panel 2 ー B465 3 ー Fire alarm connection 4 ー Fire supervisory connection 5 ー Trouble AC Fail Low Battery...

Page 23: ...1 2 3 Figure 4 6 B46 cable connection Callout ー Description 1 ー B465 module 2 ー B46 3 ー B46 Cable P N F01U310747 included with the B46 Notice The B46 connector is keyed so it can plug in only one way Notice Ensure the placement of the B46 cable does not obstruct the LEDs of the B465 when inserting into the port of the B465 4 7 5 Input loop wiring The four inputs connect to dry contact outputs on t...

Page 24: ...s to provide a reference for supervision The total resistance for the wire length and contacts minus the end of line EOL resistor must not exceed 100 Ω 2 21 kΩ 8 1 4 5 6 7 2 3 2 3 2 3 9 Figure 4 7 On board input loop wiring Callout ᅳ Description 1 ᅳ 100 Ω maximum total wire out and back 2 ᅳ Input terminal 3 ᅳ Common 4 ᅳ Normally closed contacts NC 5 ᅳ Normally open contacts NO 6 ᅳ Combination Norm...

Page 25: ... Input voltage parameters Warning UL Commercial Fire requirement do not connect multiple wires to any B465 terminal If multiple wires are required connect a single wire to the terminal then connect multiple wires to the single wire using a wire nut or other approved method The graphic below is an example of multiple wire connections to a terminal 1 Figure 4 9 Multiple wire connections to a termina...

Page 26: ...65 to use 24 VDC from a UL listed fire control panel or power supply as the primary power source The default configures the B465 to use AC as the primary power source You can use a D1640 plug in transformer D1640 CA plug in transformer or D1640 120WI wired in transformer These transformers have a rating of 16 5 VAC 40 VA Earth ground connection first To help prevent damage from electrostatic disch...

Page 27: ...ion require that you install a D8004 Transformer Enclosure if you are using either the D1640 or D1640 CA plug in transformers DC operation When the Primary Power Source is set to DC the B465 makes a DC power failure event when the voltage at the primary power 24 VDC or 16 5 VAC terminals is not sufficient or when the polarity of the DC power source is reversed The Primary Power Fail Delay paramete...

Page 28: ...ted fire control panel or UL Listed power supply Callout Description 1 Conduit required for use with external wiring 2 24 VDC from UL Listed fire control panel wiring or UL Listed power supply wiring 3 Battery wires red and black 4 12 V 7 18 Ah sealed lead acid rechargeable battery D126 D1218 5 B465ground wire connection Notice 24 VDC primary power source is polarity sensitive If you reverse the p...

Page 29: ...ase backup time The D1218 is a 12 V 18 Ah battery for use in applications requiring extended battery standby time The module does not support more than 18 Ah Install the battery 1 Place the battery upright in the base of the enclosure 2 Locate the red and black leads supplied within the packaging contents 3 Connect the black battery lead to the B465 BATTERY terminal and then to the negative side o...

Page 30: ...R Y G B SDI2 Device Bus BATTERY PANEL LINE 1 BATTERY POWER RX TX SYSTEM TROUBLE INPUTS 2 2 k End of Line Resistors C NO RELAY 3 12V AUX COM T R PNL LINE 2 24 VDC or 16 5 VAC 2 BATTERY Figure 4 11 NON power limited wiring for a plug in transformer Callout ー Description 1 ー Conduit required for use with external batteries 2 ー D1640 UL Listed Class 2 Plug in Transformer 16 5 VAC 40 VA 60 Hz 3 ー 0 25 ...

Page 31: ...quired for use with external batteries 2 ー Battery terminals BATTERY is non power limited 3 ーD1640 120WI UL Listed Class 2 Wired Transformer 16 5 VAC 40 VA 60 Hz tuck the wires behind the battery to ensure the proper clearance 4 ー 12 VDC sealed lead acid rechargeable battery D126 D1218 5 ー Battery wires red and black 6 ー B465 ground wire connection tuck the wires behind the battery to ensure the p...

Page 32: ...trol panel sends a BATTERY MISSING report or Control Panel Battery Missing 311 report in the Contact ID format When battery voltage returns to 13 4 V or higher the B465 turns the LOW BATTERY LED off If the B465 is programmed for battery supervision it sends a BATTERY RESTORAL report or a Control Panel Battery Restored to Normal 302 report in the Contact ID format Investigate LOW BATTERY events imm...

Page 33: ...he B465 supervises its on board Ethernet communicator when it is configured as either the preferred network technology or the alternate network technology Supervision ensures reliable end to end network communications If the on board Ethernet communicator does not receive a response to supervision polls the B465 creates a communication trouble event The trouble shows on the trouble LED You can con...

Page 34: ...ondary Receiver parameter is set to Disabled In the Standard Communication Configuration menu the Preferred Network Technology parameter is set to Ethernet or Cellular The Alternate Network Technology parameter is set to Enabled After two failed attempts to send a report using the Preferred Network Technology the B465 uses the Alternate Network Technology For example you select Cellular as your pr...

Page 35: ...ernate network technologies fail the B465 creates a communication failure event Cellular and Ethernet network technology communication paths The figure below shows cellular and Ethernet network technology communication paths 10 2 5 TMPR BAT ETHERNET EXTERNAL ANNUNC X MODULE 1 Y MODULE RELEASE 1 COM 2 PNL LINE 2 3 COM 4 PNL LINE 1 C NO RELAY 2 BAT 18VAC NO C NC RELAY 1 TRBL TX RX AC PANEL LINE 2 US...

Page 36: ...nitoring station when cellular communications are disrupted To enable encryption for IP network communications refer to the AES Encryption parameters in Primary Receiver page 60 and Secondary Receiver page 63 5 4 Compatible central station receivers Sending Conettix IP reports requires a Bosch central station receiver The following receivers are compatible with B465 Conettix D6600 Communications R...

Page 37: ...ompatible with firmware v2 00 The B465 driver RB_465 inf is not compatible with B465 firmware v2 00 Before you can access the USB user interface you must install or browse to the RBUS1CP inf file on the target PC or laptop The B465 USB driver RBUS1CP inf file is available on the supplied user CD You need to install this file only once on the target computer Installing the driver from the web 1 Fro...

Page 38: ...e is B465 Dual Path Communicator 14 Install a communication program to configure the B465 Figure 6 1 RB_B465 inf installed inside Device Manager 6 2 1 Install TeraTerm Install a serial communication program to establish communication from a computer to the B465 For your information Windows Vista and Windows 10 8 7 installations no longer include a serial communication program when the operating sy...

Page 39: ...assistance is required Installing Tera Term When you perform the Tera Term installation follow the prompts in the installation wizard but on the Select Components page of the wizard select Compact installation from the drop down list Refer to the figure below Figure 6 2 Setup Tera Term wizard s Select Components window Tera Term version interface After installing the latest Tera Term version doubl...

Page 40: ...017 11 05 F 01U 311 207 Installation and Operation Manual Bosch Security Systems Inc Figure 6 3 Selecting the Terminal Setup window 3 Change the default setting of CR to LF from the Receive drop down menu and click OK Figure 6 4 Changing the Receive option to LF 4 Click Save setup ...

Page 41: ...lows you to have the correct display settings when you launch Tera Term in future sessions 6 Click the correct port option in the Port drop down menu for the B465 Figure 6 6 Tera Term Pro window shown 6 2 2 Log in How to log in 1 Ensure that the USB Type A male to male cable is connected to the B465 and the target computer 2 From Windows start a terminal session by launching Hyper Terminal on Wind...

Page 42: ... B465 USB login window opens Figure 6 7 B465 USB login window 5 Enter the password to log on The default password is B465 The user interface allows three attempts to enter the password correctly After three failed attempts the B465 shows a Too many attempts error message and the USB interface enters into an idle state for 30 seconds Repeat Steps 3 through 6 at the conclusion of 30 seconds 6 Press ...

Page 43: ...ter entering the password After pressing Enter without selecting an item from the main menu After selecting Exit in a sub menu Notice Use the Escape Esc key to exit without changes Pressing the Escape Esc key returns you to the previous menu without making changes Pressing the Escape key after entering data clears the data entered Notice Automatic log out after 5 minutes of inactivity The B465 aut...

Page 44: ...Ethernet 3 Alternate Network Technology 4 Number of Receiver s Back Ethernet Cellular 1 2 0 Disabled Enabled N Y 1 2 2 Receiver Setup 4 Cellular IP Address Host Name 5 Cellular Supervision Time 0 Back 1 Port Number 7700 2 Ethernet IP Address Host Name 3 Ethernet Supervision Time 6 AES Encryption 0 1 2 3 4 5 6 7 Back No Supervision 90 Seconds NFPA 72 2007 180 Seconds ULC S304 S559 200 Seconds UL 16...

Page 45: ...Configuration Tamper 4 4 5 Back Primary Power Supervision 2 0 Battery Supervision 3 Communication Failure Action Primary Power Fail sends reports 3 4 Back Primary Power Source 1 0 Primary Power Fail Delay 2 Input Power Fail sets Trouble Output Battery faults set Trouble Output 3 Back Battery Monitoring 1 0 Battery faults send reports 2 Tamper sets Trouble Output Back 1 0 Tamper sends reports 2 Com...

Page 46: ...st 5 Communicator Test Menu 0 Back 1 Receiver Communication Verbose Mode 2 Cellular Modem Verbose Mode 3 Network Communications Verbose Mode 4 Network Operations Verbose Modes 9 Exit Output Configuration 6 Output 3 Battery Trouble 3 Back Output 1 System Trouble 1 0 Output 2 Input Power Fail 2 0 Back 1 System Trouble 2 Primary Power Fail 3 Battery Fault 4 Comm Fail 5 Ethernet Comm Fail 6 Cellular C...

Page 47: ...s Advanced Status Signal Strength and Product Versions make the desired selection Status Menu Accessing the Status Menu 1 Enter the B465 passcode 2 Press 1 Status 3 Select the desired parameter Basic Status Advanced Status Signal Strength and Product Versions from the table below Option Press to select Description 1 Basic Status Menu 1 This option shows the current Ethernet technology IP address l...

Page 48: ...rsion of all entities in the B465 The following list is an example of the versions shown Product Versions B465 Product ID Cloud ID B465 Application V 2 B465 Boot Loader V B465 Hardware V RTOS V Fusion Stack V Cellular Manager V UPKI Encryption V AES Lib V Modem Firmware V Tab 6 2 Status sub menu parameters Link Status Parameter Description IP Address Cellular Network This field displays the curren...

Page 49: ...propriate fields If no modem status is detected the following message appears Modem status is not available Parameter Description Electrical Serial ESN This field displays the B44x radio modem serial number Data Status This field displays one of the following Disconnected Connecting or Connected Signal Strength This field displays the current signal strength One of the following appears Very good ...

Page 50: ...ellular DNS lookup error secondary receiver Ethernet DNS lookup error IPv4 test address Ethernet DNS lookup error IPv6 test address Cellular DNS lookup error IPv4 test address Cellular DNS lookup error IPv6 test address Supervision of primary receiver over Ethernet failed Supervision of primary receiver over cellular failed Supervision of secondary receiver over Ethernet failed Supervision of seco...

Page 51: ...ld shows an alternate IP address DNS Status This field shows one of the following OK Error No Status no DNS lookup has been performed UDP Packets Transmitted This field shows the packets transmitted over the Ethernet or cellular reporting path from power up or Option 3 Reset Status Advanced Modem Status Parameter Description Transceiver Model number This field shows one of the following DE910 DUAL...

Page 52: ...tion Configuration menu refer to Communication Configuration page 58 6 3 4 4 System Configuration For information on the parameters in the System Configuration menu refer to System Configuration page 72 6 3 5 5 Input Configuration 6 Output Configuration For information on the parameters in the Input Configuration menu and Output Configuration menu refer to Input Configuration page 78 and Output Co...

Page 53: ...can log for longer periods of time LED Sounder Test Use this option to test the operation of the piezo sounder Communicator Test Menu Use this option to test communication paths between the B465 and the connected receivers 2 Change Passcode 2 Select this option to change the passcode used to enter in the USB menu Enter a new passcode twice to change it The second entry confirms the new passcode Pa...

Page 54: ...at contains a Technical Service Note verify your B465 is updated to the latest firmware version If you plug in B440 v15 00 026 and B441 v18 02 022 without having the B465 firmware v1 00 005 or higher installed the B465 registers on the network but will not obtain an IP address or send data Update with the USB interface and Tera Term To update the B465 using the USB interface and Tera Term follow t...

Page 55: ...as it waits for the firmware File Transfer XMODEM Send process to begin If the transfer process takes longer than 90 second to locate the file and begin the send process the menu times out and the user must begin the update process again 6 From the Tera Term main menu select File Transfer XMODEM Send 7 In the XMODEM Send dialog window navigate to the folder location and select the firmware update ...

Page 56: ... Dual Path Communicator 2017 11 05 F 01U 311 207 Installation and Operation Manual Bosch Security Systems Inc Figure 6 12 File navigation 8 Click Open to start the firmware update The Tera Term XMODEM Send dialog box opens and indicates the update process ...

Page 57: ...utomatically Within the Tera Term window an updating to firmware version x xx xxx message displays and the B465 automatically reboots 10 Close the Tera Term session and re launch Tera Term Notice Do not power off the module during this phase Powering off might cause permanent damage to the B465 11 Log back into Tera Term as described previously to re establish communication from your laptop to the...

Page 58: ...ubstitute Account Number Default Disabled Selections Enabled Before the B465 sends the reports from the control panel to the central station receiver it substitutes replaces the account number in the report with the Alternate Account Number Disabled the B465 does not replace the account number in reports USB Menu Location 3 Advanced Communication Configuration 1 Account Setup 5 Substitute Account ...

Page 59: ...you select here for sending reports to the central station receiver If communication to the central station receiver fails and the Alternate Network Technology is enabled the B465 tries to send reports using the Alternate Network Technology If you set this parameter to Ethernet Cellular is the Alternate Network Technology If you set this parameter to Cellular Ethernet is the Alternate Network Tech...

Page 60: ...t 7 6 2 Cloud Remote Connect Cellular Default Disabled Selections Enabled use an optional plug in cellular communicator for Cloud Remote Connect connections Disabled do not use an optional plug in cellular communicator Remote Connect is a Bosch Cloud based Service that allows RPS to connect to the B465 for programming and diagnostics Notice Bosch Installer Services Remote Connect subscription requ...

Page 61: ... 2 Port Number Default 7700 Selections 1 to 65 535 This is the port number the B465 uses for communication with the central station receiver USB Menu Location 2 Standard Communication Configuration 4 Primary Receiver 1 Port Number or 3 Advanced Communication Configuration 2 Receiver Setup 1 Primary Receiver 1 Port Number 7 7 3 Ethernet Supervision Time Default 1 hour Selections No polling 90 secon...

Page 62: ...dvanced Communication Configuration 2 Receiver Setup 1 Primary Receiver 4 Cellular IP Address Host Name 7 7 5 Cellular Supervision Time Default 1 hour Selections No polling 90 seconds 180 seconds 200 seconds 5 minutes 1 hour 4 hours 24 hours The B465 must receive an ACK acknowledgement to a heartbeat poll within the time defined by the Cellular Supervision Time parameter To reduce network traffic ...

Page 63: ...ter to 2 to configure the parameters for the secondary receiver USB Menu Location 3 Advanced Communication Configuration 1 Account Setup 4 Number of Receivers 7 9 Secondary Receiver You can configure the B465 to send reports to one or two central station receivers primary receiver secondary receiver Use the parameters in this section to configure the secondary receiver To access these parameters f...

Page 64: ...l rate ACK wait time and Retry Count to support the Ethernet Supervision Time you select If the B465 does not receive an ACK to a heartbeat poll after the retry count is met it creates a Communication Trouble event USB Menu Location 3 Advanced Communication Configuration 2 Receiver Setup 2 Secondary Receiver 3 Ethernet Supervision Time 7 9 4 Cellular IP Address Host Name Default blank Selections I...

Page 65: ...isabled 128 bits 16 bytes 192 bit 24 bytes 256 bit 32 bytes Select the key size for AES encryption USB Menu Location 3 Advanced Communication Configuration 2 Receiver Setup 2 Secondary Receiver 6 AES Encryption 7 9 7 AES Encryption Key Default Default not encrypted Selections Thirty two hexadecimal characters represented by an ID 01 to 100 The AES Encryption Key is based on AES Key Size AES key st...

Page 66: ...s is set by the DHCP service do not change it A Domain Name Server DNS converts internet domain names or hostnames to their corresponding IP addresses In DHCP mode the DHCP server s default DNS is used To use a custom DNS server in DHCP mode change the parameter to the custom DNS server s IP address This IPv6 DNS server address is the only IPv6 address entered as numbers Further information IP Add...

Page 67: ...etwork mask here Further information IP Address and Domain Name formats USB Menu Location 3 Advanced Communication Configuration 3 Ethernet Setup 2 IPv4 Configuration 3 IPv4 Subnet Mask 7 10 8 IPv4 Default Gateway Default 0 0 0 0 Selections 0 0 0 0 to 255 255 255 255 If DHCP Auto IP for IPv4 is set to Enabled this parameter is grayed out no access to it If DHCP Auto IP for IPv4 is set to Disabled ...

Page 68: ...ain Name formats USB Menu Location 3 Advanced Communication Configuration 3 Ethernet Setup 2 IPv4 Configuration 7 IPv4 Test Address 7 10 12 UPnP Universal Plug and Play Default Enabled Selections Enabled use UPnP to open a port forwarder for inbound RPS connections Disabled do not use UPnP The UPnP parameter has no effect on event reporting to a central station receiver When this parameter is set ...

Page 69: ...pical installations keep the port number at the default USB Menu Location 3 Advanced Communication Configuration 3 Ethernet Setup 6 TCP UDP Port Number 7 11 Cellular Setup Cellular Plug in Module Use the parameters in this section to configure the B465 for the cellular plug in communicator module 7 11 1 Network Access Point Name APN Default EAAA BOSCH VZWENTP Selections 0 99 A Z a z This parameter...

Page 70: ...s inbound SMS text messages Disabled the B465 does not process inbound SMS text messages USB Menu Location 3 Advanced Communication Configuration 4 Cellular Setup 2 Inbound SMS 7 11 6 Reporting Delay for Low Signal Strength minutes Default 0 Selections 0 disabled 60 minutes Time in minutes of low signal strength red LED on cellular communicator before the control panel creates a Cellular Low Signa...

Page 71: ...to 255 255 255 255 A Domain Name Server DNS converts internet domain names or hostnames to their corresponding IP addresses In DHCP mode the DHCP server s default DNS is used To use a custom DNS server in DHCP mode enter the custom DNS server s IP address here Further information IP Address and Domain Name formats USB Menu Location 3 Advanced Communication Configuration 4 Cellular Setup 5 IPv4 DNS...

Page 72: ... IIIa2 handshake tone for Bosch Radionics Modem IIe and Modem IIIa2 formats Select the handshake tone for the reporting format the control panel connected to the B465 uses Notice Connected control panel might need the correct handshake sent first The connected control panel might require that the correct handshake tone is sent first or it will not send the report If you selected Auto Detect and th...

Page 73: ...cial fire systems set this parameter to Enabled USB Menu Location 4 System Configuration 2 Primary Power Supervision 3 Primary Power Fail sends reports 8 2 4 Primary Power Fail sets Trouble Output Default Disabled Selections Enabled when primary power fails the B465 sets the trouble output Disabled the B465 does not set the trouble output when primary power fails The B465 waits the time set in the...

Page 74: ...fault Disabled Selections Enabled when there is a battery fault the B465 sets the trouble output Disabled the B465 does not set the trouble output for battery faults USB Menu Location 4 System Configuration 3 Battery Supervision 3 Battery faults set Trouble Output 8 4 Tamper Use the parameters in this section to configure the B465 to monitor an enclosure tamper switch 8 4 1 Tamper sends reports De...

Page 75: ...em trouble output Disabled the B465 does not set the system trouble output for communication failure events USB Menu Location 4 System Configuration 5 Communication Failure Action 2 Comm Fail sets Trouble Output 8 5 3 Comm Failure removes Line 1 phone voltage Default Disabled Selections Enabled when there is a communication failure event the B465 removes voltage to the PNL LINE 1 terminals termina...

Page 76: ...n 6 Module Supervision 1 Module Faults send reports 8 6 2 Module Faults set Trouble Output Default Disabled Selections Enabled when there is a module fault event the B465 sets the system trouble output Disabled the B465 does not set the system trouble output for module fault events USB Menu Location 4 System Configuration 6 Module Supervision 2 Module Faults set Trouble Output 8 7 RPS Settings 8 7...

Page 77: ... parameter Module Faults set Trouble Output page 76 is set to enabled and there is a module fault the B465 sends a PERIODIC TEST with system trouble present report If the sensor loop for an enabled Input 1 to 4 page 78 is shorted or open the B465 sends a PERIODIC TEST with system trouble present report If there are no module faults and sensor loops for all inputs are normal not shorted or open the...

Page 78: ...B465 sends a Contact ID 371 Protection Loop Open report Fire Alarm when the sensor loop for this input is shorted the B465 sends a Contact ID 110 Fire alarm report When the sensor loop is open the B465 sends a Contact ID 373 Fire Trouble report Fire Trouble when the sensor loop for this input is shorted or open the B465 sends a Contact ID 373 Fire Trouble report Fire Supervisory when the sensor lo...

Page 79: ... when the primary power source is failed Panel AC Fail when a B465 is input configured for Panel AC Fail is shorted the B465 activates this output Battery Fault when there is a battery fault condition the B465 activates this output Comm Fail when there is a communication fail condition the B465 activates this output Ethernet Comm Fail when there is a communication fail condition using the onboard ...

Page 80: ...Tab 11 4 100BASE T LED descriptions Flash pattern Function On Steady Plugged into an Ethernet network Flashing Communication in progress flashes during communications but remains on when not communicating Off Unplugged from an Ethernet network or the Ethernet network is not available Tab 11 5 LINK LED descriptions Panel Phone Line 1 and Panel Phone Line 2 LEDs The LED for panel phone line 1 is loc...

Page 81: ...N HOOK Tab 11 6 Phone line 1 and 2 LED descriptions Conettix Plug in cellular module LEDs LED Function Blue Indicates the overall status of the device Red Indicates an unacceptable signal strength level Yellow Indicates a marginal signal strength level Green 1 light Indicates a good signal strength level Green 2 lights Indicates a very good signal strength level One green LED indicates the minimum...

Page 82: ...rnet communication errors Refer to SYSTEM TROUBLE Flashing one flash Ethernet table for more information Flashing Indicates cellular communication errors Refer to SYSTEM TROUBLE Flashing two flashes Cellular table for more information Flashing Indicates a communication trouble or failure Verify IP address and port numbers entered in the central station receiver Make sure the account is enabled in ...

Page 83: ...rk administrator has setup your device correctly Refer to USB menu options to change edit your IP address Flashing three flashes Indicates an Ethernet DNS Lookup error Make sure you have an Internet connection that has access to the world wide web Tab 11 10 Ethernet LED descriptions SYSTEM TROUBLE Flashing two flashes Cellular Trouble Heartbeat LED RX LED Plug in Status LED Function On Steady Flas...

Page 84: ... four flashes On Steady Indicates a cellular DNS Lookup error Check the name entered to verify it was entered correctly Flashing Flashing five flashes On Steady Indicates no activation Check with your service provider to make sure the cellular module was activated Flashing Flashing six flashes On Steady Indicates an invalid access point Check the APN against the APN required by your service provid...

Page 85: ...issing Verify the SIM card is inserted into the B442 or B443 cellular communication module Refer to the SIM card page 90 troubleshooting section for more information Flashing Off Flashing four flashes Indicates a SIM Card lockout This requires that the SIM PIN be used to unlock the SIM card Flashing Off Flashing five flashes Indicates an invalid SIM PIN Verify the correct SIM PIN was entered Refer...

Page 86: ...or 72 hours Replace the battery with a new one Flashing four flashes Indicates a battery charger failure Failure can only be cleared by powering down the module and rebooting If the problem continues the module will require a board replacement Tab 11 13 BATTERY LED descriptions 11 2 B46 LED status and sounder Refer to the following table for LED status indicators SYSTEM TROUBLE LED patterns Flash ...

Page 87: ...r Flashing Indicates multiple communication errors Check the B465 USB status menu for additional information to help correct the problem On Steady Indicates all non IP communication troubles For example low or missing battery phone lines are off the hook for more than 2 minutes or there is a configuration issue Tab 11 14 SYSTEM TROUBLE LED descriptions POWER LED Flash pattern Function On Steady In...

Page 88: ...ng battery voltage on the B465 module The sounder emits an audio tone for once every ten seconds when the B465 module programming for Battery Supervision is enabled This pattern is repeated until the battery power issue is restored Configuration errors The sounder emits a double beep audio tone every 4 seconds when a configuration error is detected The pattern is repeated until the configuration i...

Page 89: ...w the system works but depend on the security level needed For more information regarding proper data plans and installation parameters related to network polling refer to Bosch Cellular Service User Guide P N F01U273558 11 6 Troubleshooting procedures Refer to the following section for troubleshooting hardware and software issues 11 6 1 No power on the B465 Description The power wiring or power s...

Page 90: ...M card This is applicable to cellular communicators that have SIM cards B442 and B443 Solution 1 Check for the presence of a SIM in the holder 2 Install the SIM card and power up the module Powering up Recognizes the SIM card 3 Check for damage to the SIM card holder 4 Remove and reseat the SIM card in the holder Check to make sure the gold contact area on the SIM card is facing towards the board ...

Page 91: ...o happen if only one tower is within RF range and it has an outage The module continues to attempt to establish communications Solution 1 Refer to Wireless Reception Issues if the signal strength is unacceptable 2 Replace the SIM card with a known good test card If the signal strength is acceptable confirm that the wireless service provider activated this account and the SIM card correctly 3 If th...

Page 92: ...k Ok 5 Press the Enter key and login 11 7 Testing the system Test the system completely after installing and programming the B465 Test the B465 the control panel and all devices once a week for proper operation Notice After system installation and any B465 programming perform a complete system test UL 864 requirement A complete system test includes testing the control panel B465 all devices and co...

Page 93: ...Conettix Universal Dual Path Communicator Maintenance and troubleshooting en 93 Bosch Security Systems Inc Installation and Operation Manual 2017 11 05 F 01U 311 207 ...

Page 94: ...B10 Medium Control Panel Enclosure 35 6 cm x 31 8 cm x 7 6 cm 14 in x 12 5 in x 3 in B11R Small Control Panel Enclosure 27 8 cm x 25 9 cm x 8 32 cm 10 9 in x 10 2 in x 3 3 in B11 Small Control Panel Enclosure 27 8 cm x 25 9 cm x 8 32 cm 10 9 in x 10 2 in x 3 3 in D8103 Universal Enclosure 41 cm x 41 cm x 9 cm 16 in x 16 in x 3 5 in B12 Mounting Plate for D8103 Enclosure 23 5 cm x 21 92 cm x 1 27 c...

Page 95: ...0 digit account codes Pulse 3 1 3 1 Checksum 2300 Hz ACK Tone Pulse 3 1 3 1 Checksum 1400 Hz ACK Tone Pulse 4 2 2300 Hz ACK Tone Pulse 4 2 1400 Hz ACK Tone SIA SIA8 SIA 20 110 and 300 baud Compatible cellular modules B440 Conettix Plug in Communicator Cellular 3G B441 Conettix Plug in CDMA Cellular Communicator B442 Conettix Plug in GPRS Cellular Communicator B443 Conettix Plug in HSPA Cellular Co...

Page 96: ...er to the 24 VDC Input Power Refer to the Standby battery requirements and calculations section in the B465 Installation and Operation Guide for the current draw requirements of other system components Power outputs All external connections are power limited The battery terminals are not power limited Ethernet connection optional 10BASE T 100BASE TX Maximum wiring distance 100 m 328 ft using cat 5...

Page 97: ...0 CUL 15 UL Local Burglary Mercantile 24 30 CUL 15 UL Commercial Fire 24 30 CUL 5 UL Residential Fire 24 5 CUL 4 UL Table 12 18 Minimum standby and alarm times Notice UL Commercial Burglary Application Requirements Mount the module in the B465 enclosure If the unit is used in a commercial burglar environment and is enclosed in a commercial enclosure that enclosure must be tampered The B465 must be...

Page 98: ...____ 150 x 1 ____ Aux Power 0 500 mA ______ _____ x Qty ______ ______ x Qty ______ ____ ______ _____ x Qty ______ ______ x Qty ______ ____ ______ _____ x Qty ______ ______ x Qty ______ Total B ____ Total C ____ Table 12 19 Current rating chart for standby battery calculations Notice Maximum power supply current for Total B in the table above is 705 mA and the maximum power supply current for Total...

Page 99: ...___ 23 x 1 ____ 23 x 1 ____ B450 B208 B308 B440 ______ 35 x 1 ____ 150 x 1 ____ B441 ______ 35 x 1 ____ 150 x 1 ____ B442 ______ 35 x 1 ____ 150 x 1 ____ B443 ______ 35 x 1 ____ 150 x 1 ____ B444 ______ 35 x 1 ____ 150 x 1 ____ Aux Power 0 500 mA ______ _____ x Qty ______ ______ x Qty ______ ____ ______ _____ x Qty ______ ______ x Qty ______ ____ ______ _____ x Qty ______ ______ x Qty ______ Total...

Page 100: ...64 Yes No Possible settings Settings permitted in UL 864 Primary Power Source page 72 set to AC Yes AC DC AC when using transformer as source Primary Power Fail Delay page 73 Yes 0 to 255 minutes 60 to 180 minutes Primary Power Fail sends reports page 73 Yes Enabled Disabled Enabled if sending report from B465 disabled if using relay outputs to control panel Primary Power Source page 72 set to DC ...

Page 101: ... 207 Ethernet Supervision Time page 61 Cellular Supervision Time page 62 Yes No Supervision 90 seconds 180 seconds 200 seconds 300 seconds 1 hour 4 hours 24 hours 4 hour supervision can be used when dual technologies are used Sole path times depends on the NFPA standard being used always consult your local AHJ 90 seconds 180 seconds 200 seconds 300 seconds 1 hour ...

Page 102: ...s Mains power supply below 85 of rated supply shall be detected and transmitting to the receiving centre in not more than 3 hours Primary Power Fail Delay set to 0 180 minutes If the signal receiving centre equipment is completely duplicated with standby equipment and a switchover can be accomplished in not more than 90 seconds with no loss of signals during this period the capacity of the system ...

Page 103: ...Conettix Universal Dual Path Communicator Specifications and certifications en 103 Bosch Security Systems Inc Installation and Operation Manual 2017 11 05 F 01U 311 207 ...

Page 104: ...No Opt Opt Opt Opt Opt B10R Medium Control Panel Enclosure Red Opt Opt Opt Opt No Opt Opt Opt Opt Opt B11 Small Control Panel Enclosure Opt Opt Opt Opt No Opt Opt Opt Opt Opt B11R Small Control Panel Enclosure Red Opt Opt Opt Opt No Opt Opt Opt Opt Opt B440 Conettix Plug in Cellular Communicator Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt B441 Conettix Plug in Cellular Communicator Opt Opt Opt Opt Opt...

Page 105: ...VAC 40 VA 60 Hz Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt D8004 Transformer Enclosure Opt Opt Opt Opt No Opt Opt Opt Opt Opt D8103 Universal Enclosure Opt Opt Opt Opt No Opt Opt Opt Opt Opt D8108A Attack Resistant Enclosure Opt Opt Opt Opt Req Opt Opt Opt Opt Opt Key Description No Not acceptable for this application Req Required for this application Opt Optional for this application 1 1 or more req...

Page 106: ... Cellular Communicator x x x B442 B442 Conettix Plug in GPRS Cellular Communicator B443 B443 Conettix Plug in HSPA Cellular Communicator x x x x B444 B444 Conettix Plug in Cellular Communicator x x x x D126 Battery 12 0 VDC 7 Ah x x x x D1218 Battery 12 V 18 Ah x x x x D1640 UL Listed Class 2 Plug in Transformer 16 5 VAC 40 VA 60 Hz x x x D1640 120WI UL Listed Class 2 Wired Transformer 16 5 VAC 40...

Page 107: ...ntrol Units and Accessories for Fire Alarm Systems UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units UL 1076 Proprietary Burglar Alarm Units and Systems UL 1610 Central Station Burglar Alarm Units Canada CAN ULC S303 Local Burglar Alarm Units and Systems CAN ULC S304 Signal Receiving Centre and Premise Alarm Control Units ULC 545 Residential Fire Warning Syste...

Page 108: ...t and sends a BURGLARY report 13 3 130 99 iii BURGLARY restoral When a B465 input that is configured for Burglary Alarm returns to normal after being shorted the B465 makes a Panel BURGLARY Alarm Restoral event and sends a BURGLARY restoral report 14 1 137 99 000 TAMPER The B465 sends TAMPER reports for faults on the tamper circuit When an enclosure tamper switch is connected to the B465 tamper ci...

Page 109: ...ured for Panel AC Fail is shorted the B465 makes a Panel AC Fail event and sends an AC LOSS report When the primary power source for the B465 fails the B465 makes a Primary Power Fail event and sends an AC LOSS report iii 000 3 3 301 99 iii AC LOSS restoral When a B465 input that is configured for Panel AC Fail returns to normal after being shorted the B465 makes a Panel AC Fail Restoral event and...

Page 110: ... 31 3 303 99 000 RAM CHECKSUM BAD restoral When the checksum for the B465 configuration parameters is corrected the B465 makes a Configuration Checksum Restoral event and sends a RAM CHECKSUM BAD restoral report 32 1 304 99 000 ROM CHECKSUM BAD When the checksum for the B465 firmware is incorrect the B465 makes a Firmware Checksum Failure event and sends a ROM CHECKSUM BAD report 30 1 305 99 000 S...

Page 111: ...ar module SIM PIN not needed Cellular configuration incorrect Cellular not registered for Bosch Cellular Service Cellular invalid access point Cellular IP address incorrect Cellular low signal Cellular one or no cellular towers detected 28 3 330 99 000 SYSTEM PERIPHERAL TROUBLE restoral When the B465 detects all of the fault conditions above are cleared it creates a generic trouble restoral event ...

Page 112: ...Ethernet IP ttt 012 DNS failure using Cellular IP 28 3 350 99 ttt COMMUNICATION TROUBLE restoral When any of the communication trouble events shown above clears the B465 sends a COMMUNICATION TROUBLE Restoral report 24 1 354 99 000 FAILURE TO COMMUNICATE When there is a communication failure event the B465 inserts a FAILURE TO COMMUNICATE report Contact ID 354 at the top of the report queue It is ...

Page 113: ...toral event and sends a FIRE TROUBLE Restoral report 10 1 380 99 iii BURGLARY TROUBLE When a B465 input that is configured for Burglary Trouble is shorted the B465 makes a Panel Burglary Trouble event and sends a BURGLARY TROUBLE report 9 3 380 99 iii BURGLARY TROUBLE restoral When a B465 input that is configured for Burglary Trouble returns to normal after being shorted the B465 makes a Panel Bur...

Page 114: ......

Page 115: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2017 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...

Reviews: