background image

Conettix Plug-in Communicator
Interfaces

B450

en

Installation and Operation Guide

Summary of Contents for B450

Page 1: ...Conettix Plug in Communicator Interfaces B450 en Installation and Operation Guide ...

Page 2: ......

Page 3: ...ol panel 15 4 5 1 Connecting to SDI2 and SDI control panels 15 4 5 2 Connecting to option bus control panels 16 5 Configuration 17 5 1 Configuration parameters 17 5 2 Plug and Play PnP configuration 21 5 2 1 RPS configuration 21 5 3 USB configuration 22 5 3 1 Get started 22 5 3 2 B450 home page 26 5 3 3 Main Menu 28 5 3 4 Status menu 29 5 3 5 Basic and Advanced Configuration menus 34 5 4 SMS confi...

Page 4: ... such as anti static wrist strap ESD damage ranges from subtle performance degradation to complete device failure Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications Warning Failure to follow these instructions can result in a failure to initiate alarm conditions Bosch Security Systems...

Page 5: ...ation Copyright This document is the intellectual property of Bosch Security Systems Inc and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly 2 2 Bosch Security Systems Inc product manufacturing dates Use the serial number located on the product label and ref...

Page 6: ...ically configure the module to work with a compatible control panel Refer to Bus address settings page 9 Insert a plug in communicator into the module Refer to Inserting a plug in cellular module required page 12 Mount the module into the enclosure Refer to Mounting the module page 13 Wire the module to a compatible control panel Refer to Connecting the module to the control panel page 15 Power up...

Page 7: ...amming workstation 4 ᅳ USB connection for module configuration 9 ᅳ Compatible IP receiver Bosch D6100IPv6 shown 5 ᅳ B44x plug in communicator available separately 3 1 Module overview The module is a four wire powered SDI SDI2 or option bus device that provides two way communication over commercial cellular networks using a plug in communicator To configure the module use one of the following tools...

Page 8: ...received from the wireless network 8 ᅳ TX LED indicates packets transmitted over the wireless network 9 ᅳ Terminal strip to control panel 10 ᅳ Interconnect wiring connectors to control panel or other compatible modules 3 2 Cellular interface compatibility The module supports multiple bus types Refer to the table to determine the supported applications and features by bus type Installed Bus Functio...

Page 9: ...through the use of Bosch cellular communication modules Refer to the following table to determine the supported Bosch cellular module and corresponding cellular network technology Cellular technology compatibility Device Cellular networks 2G CDMA 3G CDMA GPRS GSM HSPA GSM 4G LTE B440 B440 C X X B441 B441 C X B442 X B443 X X B444 X Check for availability in your region 3 3 Bus address settings The ...

Page 10: ...ress Bus type Function USB or SMS configuration setting 0 N A Any Configuration B9512G B8512G B6512 B5512 B4512 B3512 D9412GV4 D7412GV4 D7212GV4 1 1 SDI2 Automation Remote Programming Reporting B9512G B8512G D9412GV4 D7412GV4 D7212GV4 2 2 Automation Remote Programming Reporting D9412GV4 D7412GV4 D7212GV4 D9412GV3 D7412GV3 D7212GV3 D9412GV2 D7412GV2 D7212GV2 v7 06 4 88 SDI1 Remote Programming or Re...

Page 11: ...Bus type Function FPD 7024 v1 06 6 1342 Option Remote Programming Reporting FPD 7024 9 250 Remote Programming Reporting 1 For D9412GV4 D7412GV4 D7212GV4 configurations SDI2 bus connection is the recommended configuration option but SDI bus configuration is also supported 2 The FPD 7024 must be at firmware version 1 06 or greater in order to configure using bus address 134 Tab 3 1 Address switch se...

Page 12: ...rting a plug in cellular module required Notice SIM cards Some plug in cellular modules require that you install a SIM card first If the B44x you install does not require one do not perform that step Notice Correct installation Push the plug in cellular module into the B450 until the module clicks into position 2 3 1 Callout ᅳ Description 1 ᅳ SIM card required for some cellular modules available s...

Page 13: ...d inside an attack resistant enclosure Notice Wiring considerations If you use terminal strip wiring instead of interconnect wiring wire the B450 module to the compatible control panel before you mount it into the enclosure to make the installation easier Notice Mounting considerations Choose from the following mounting options before you mount the module Mount the B450 on the inside enclosure wal...

Page 14: ...els that are compatible with an enclosure tamper switch you can use this module to connect and monitor the tamper switch 1 Install the ICP EZTS tamper switch Use the instructions in the switch installation manual P N F01U003734 2 Connect the wire of the installed tamper switch wire to the tamper switch connector on the module 4 4 Installing the cellular antenna 1 2 Callout ᅳ Description 1 ᅳ Plug i...

Page 15: ...l strip wiring or interconnect wiring to the control panel Do not use both When connecting multiple modules you can combine terminal strip and interconnect wiring connectors in series Notice Combination SDI2 SDI control panels For combination control panels use the SDI2 terminals R Y G B R Y G B 3 7 5 0 VDC 2 0 3 0 VDC 0 0 1 3 VDC Open Normal Short 3 R Y G B 1 1 2 4 2 7 COM 8 C OUTPUT B 1 k End of...

Page 16: ...els Notice When you wire the module to the option bus terminal strip on the control panel verify the terminal position of the wires Option bus terminals might differ from module terminals For example option bus R B G and Y and B450 R Y G and B R Y G B R Y G B 2 1 3 R Y G B Callout ᅳ Description 1 ᅳ Compatible control panel FPD 7024 control panel shown 2 ᅳ B450 3 ᅳ Terminal strip wiring ...

Page 17: ...in the USB menus Not all parameters are available in all configuration programs USB menu 3 Basic Configuration TCP UDP Port Number Default 7700 Selections 0 65535 For IP communications with RPS automation or Remote Security Control RSC in typical installations keep the TCP UDP Port at the default AES Encryption Default No Encryption Selections No Encryption 128 bits 16 bytes 192 bit 24 bytes 256 b...

Page 18: ...int Name APN Default wyless apn Selections 0 9 A Z a z up to 99 characters Enter up to 99 characters for the network access point name APN The APN is case sensitive Network Access Point User Name Default Blank Selections ASCII characters up to 30 Enter up to 30 ASCII characters for the Network Access Point user name The user name is case sensitive Network Access Point Password Default Blank Select...

Page 19: ... 587 or port 465 to avoid the block Email Server Authentication Encryption Default Authenticate Selections Basic no authentication no encryption Authenticate authentication required no encryption Encrypted authentication required encryption required Select the security level required by the email server to receive messages from the control panel Authentication User Name Default Blank Selections Bl...

Page 20: ...unless you are on an SDI2 control panel or AMAX 2100 3000 4000 with Panel Programming Enable enabled With SDI and other option control panels you must use the USB interface Web Access Password Default B42V2 Selections blank ASCII printable characters This parameter sets the password required to log in for web access The password must be 4 10 ASCII printable characters in length Blank spaces disabl...

Page 21: ...4000 firmware version v1 5 or higher B9512G B9512G E B8512G B8512G E B6512 B5512 B5512E B4512 B4512E B3512 B3512E D9412GV4 D7412GV4 D7212GV4 Solution 2000 3000 firmware version v2 0 or higher To disable this feature for PnP control panels disable the Panel Programming Enable parameter before you connect the module Notice By default when you connect a field replacement module to an existing SDI2 or...

Page 22: ...module install the USB driver and Tera Term on the connected computer The B450 CD ROM has the RBUS1CP inf USB driver and Tera Term installation files Notice RPS users You can use RPS v5 16 or higher to configure the module through a remote connection to the control panel or with a USB connection to the control panel Refer to RPS configuration page 21 Notice Male A to Male A cable required USB conf...

Page 23: ...ion Guide 2017 10 09 F 01U 300 740 Installing Tera Term 1 On the connected computer navigate to the Tera Term file from the CD ROM or zip downloaded from the website 2 Follow the prompts in the installation wizard until the Select Components page of the wizard Select Compact installation from the drop down list ...

Page 24: ...bar select Setup Terminal The Terminal Setup window opens 3 In the New line section select LF from the Receive drop down list Click OK 4 From the menu bar select Setup Save Setup A dialog box appears 5 Click Save to overwrite the existing TERATERM INI file Tera Term stores the new setting for future Tera Term sessions Logging into the module 1 Connect the USB cable to the module 2 Connect the USB ...

Page 25: ...d Operation Guide 2017 10 09 F 01U 300 740 4 From the Serial Port drop down list select the B450 for example Port COM7 B450 COM7 5 Click OK Tera Term connects 6 Press Enter A windows appears with a request to enter the passcode 7 Enter the password default is B450 and press Enter The USB main page opens ...

Page 26: ...a Term shows a Menu access disabled error message refer to USB menu access disabled page 40 5 3 2 B450 home page The B450 home page in Tera Term opens when you do one of the following Log in Press Enter before you enter a number for a menu for example 3 for Basic Configuration Exit a menu The home page includes four important sections Callout Description 1 Plug in cellular module 2 Plug in status ...

Page 27: ...status Link Status The connection status to the cellular network is OK or Error Bus Status The bus status is On Line or Not Connected Module Status The module status is Normal or Trouble Tamper The status of the tamper switch connection is Yes No or Disabled through configuration Access level overview The access level for the module is Restricted or Full Main Menu overview Refer to Main Menu page ...

Page 28: ...Menu 4 Panel Programming 5 Inbound SMS 6 Reporting Delay for Low Signal Strength 7 GSM GPRS Configuration 3 6 1 TCP UDP Port Number 2 AES Encryption 3 Module Enclosure Tamper 3 IPv4 DNS Server IP Address 4 Alternate IPv4 DNS Server IP Address 0 Basic Configuration Menu 1 Network Access Point Name APN 2 Network Access Point User Name 3 Network Access Point Password 4 SIM PIN 5 Session Keep Alive Pe...

Page 29: ...ge and then enter in the new value 4 Advanced Configuration Use to program advanced options Press 0 to return to the Main Menu To change an advanced parameter select the option to change and then enter in the new value 5 Reset to Factory Defaults Use to reset all factory default values All fields are cleared and the factory default values are restored Notice A non defaulted SDI2 control panel over...

Page 30: ... either OK or Error Encryption Shows either Normal or Trouble Socket xx Port Number Shows the current open Port Numbers and Data Types up to 32 Modem Status The information below shows in the appropriate fields If no modem status is detected the following message shows Modem status is not available Telephone Number Shows the cellular phone number if available A phone number of 000 000 0000 is list...

Page 31: ...rrent voltage Good or Low Module Status This status shows only if there is a trouble condition B44x Plug in Missing Detecting Plug in B44x Plug in Missing B44x Plug in Invalid No IP Address Detecting Plug in Signal Strength Low if configured Too Few Towers No Towers if configured B44x Not Active B44x Failure Configuration Failure Low Bus Voltage No Bus Communication Switch in Position 0 Firmware C...

Page 32: ...he following OK Error No Status no ping has been performed IPv4 DNS Server IP Address Shows the current IP address Alternate IPv4 DNS Server IP Address Shows an alternate IP address DNS Status Shows one of the following OK Error No Status no DNS lookup performed UDP Packets Transmitted Shows from power up or Option 3 Reset Status UDP Packets Received Shows from power up or Option 3 Reset Status Ad...

Page 33: ...id bus messages that the module has received If the module is on the bus and operating this number changes when refreshed Status sub menu To open a sub menu from the 1 Status Starts With Basic Status menu press the number key for the menu For example press 1 to open 1 Basic Status Menu Option Description 1 Basic Status Menu Shows the current IP address link status modem status bus status and modul...

Page 34: ...n important notes TCP UDP Port Number Character limitations Enter the 32 digit encryption key Verify the 32 digit key does not exceed the arrow prompt as shown in the figure above Use only hex values 0 9 and A F SIM PIN To erase text you must type in the word None to erase the previous text This is NOT case sensitive See also Configuration parameters page 17 5 4 SMS configuration The B450 supports...

Page 35: ...d by the ID number and the value you want to set To remove text from an SMS message use the word None or For example if you want to remove a SIM PIN using SMS enter either 4 None or 4 The word None is NOT case sensitive SMS configuration parameters ID Description 1 Current passcode 4 to 10 characters default B450 2 New passcode 4 to 10 characters 4 SIM PIN 4 to 8 characters Basic parameters 10 Net...

Page 36: ...r 1 1 1 B450 2 secret123 15 3 16 010203040506070809101112131 41516 1 B450 Current password 2 secret123 New password case sensitive 15 3 Enable AES encryption 16 01020304050607080910 111213141516 Sample AES key 1 As you enter in the various ID s into your cell phone do not press the return key Doing so will cause the B450 to ignore the programming request Double SMS example part 2 ID Description Sa...

Page 37: ...tinue until you move the bus address switch from position 0 Notice If the LEDs indicate an invalid SMS change the bus address switch from 0 and then back to 0 before you send a different SMS Refer to the tables in Maintenance and troubleshooting page 38 section for more information on LEDs Make sure that the SMS contains the correct information and that you entered the correct phone number for the...

Page 38: ... configuration page 22 2 From Windows start Tera Term 3 Log into the USB interface as described in Log into the USB interface The B450 USB login window appears listing the current software version and build 4 Select option 7 and press Enter Notice Once you press Enter the B450 begins a 90 second timer as it waits for the firmware File Transfer XMODEM Send process to begin If the transfer process t...

Page 39: ... Maintenance and troubleshooting en 39 Bosch Security Systems Inc Installation and Operation Guide 2017 10 09 F 01U 300 740 7 Click Open to start the firmware update The Tera Term XMODEM Send dialog box opens and indicates the update process ...

Page 40: ...and relaunch Tera Term 10 Log into Tera Term to reestablish the connection Communication between the control panel and B450 restores 6 2 USB menu access disabled A Menu access disabled error message occurs when the Web USB Access Enabled feature in RPS is set to No when connected to a GV4 Series v2 03 or B Series v2 03 control panel Enabling USB 1 Launch your session of RPS 2 Log into RPS 3 Select...

Page 41: ...eartbeat system status RX receive TX transmit The plug in module also includes LEDs for troubleshooting and status Flash pattern Indication Flashes once every 1 second Normal state 3 quick flashes every 1 second Communication error state Error on the bus between the module and the control panel On Steady Trouble state Examine the other LEDs to determine the trouble condition Off LED trouble state ...

Page 42: ...tible communicator documentation B450 trouble condition LEDs Condition B450 Heartbeat B450 Transmit TX B450 Receive RX Plug in module status Module tamper Not indicated Plug in module missing On Steady Off 1 quick flash repeating N A SIM card missing On Steady Off 2 quick flashes repeating Off Plug in module not recognized On Steady Off 3 quick flashes repeating Off Low bus voltage On Steady Off 4...

Page 43: ...ting Off Plug in module related trouble conditions Condition B450 Heartbeat B450 Transmit TX B450 Receive RX Plug in module status No IP address On Steady Off Off 2 quick flashes repeating Cellular number not activated On Steady Off Off 3 quick flashes repeating Not enough towers single tower On Steady Off Off 4 quick flashes repeating Invalid access point On Steady Off Off 5 quick flashes repeati...

Page 44: ...ulses the major minor and micro digits of the firmware version with a 1 second pause after each digit For example the version 1 4 3 shows as follows 3 second pause __ __ 3 second pause then normal operation 6 5 SIM card For troubleshooting plug in cellular modules that use SIM cards Make sure that the SIM card is in the holder Make sure that you install the SIM card before you apply power Check fo...

Page 45: ...ouble conditions can happen when the network carrier performs maintenance Trouble conditions can increase data volumes that affect your monthly cost Your settings for these parameters determine how the system works but depend on the security leve For more information regarding proper data plans and installation parameters related to network polling refer to Bosch Cellular Service User Guide P N F0...

Page 46: ...2 0 mm to 06 mm USB cable USB cable Type A to A male to male not supplied Data bus wire length Maximum Distance wire size 22 AWG 0 6 mm 12 m 40 ft 18 AWG 1 0 mm 30 m 100 ft 16 AWG 1 3 mm 48 m 158 ft 12 AWG 2 0 mm 122 m 400 ft You can extend the wire distances 300 m 1000 ft Use a separate power supply such as the B520 Auxiliary Power Supply Module Compatibilities Control panels B450 B9512G B8512G B...

Page 47: ...Operation Guide 2017 10 09 F 01U 300 740 Enclosures B10 B11 D8103 D203 Applications Tera Term for USB B450 configuration Hyper Terminal for USB B450 configuration RPS version 5 16 or higher Remote Security Control Remote Security Control Notice The enclosure might cause temporary loss of communication due to static ...

Page 48: ......

Page 49: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2017 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...