1 | Overview

2 | SDI2 address settings

The module’s switches provide a tens and ones value for the 

module’s address. For single-digit address numbers 1 through 

9, set the tens switch to 0 and the ones digit to the appropriate 

number. The following illustration shows the address switches 

setting for addresses 1 and 11.

Set the switches per the control panel configuration. Each 
B308 module must have a unique address.

3.1 | Install the module in the enclosure

Refer to the following illustration for installing into the enclo-

sure.

3.2 | Install and wire the tamper switch

You can connect an optional enclosure door tamper switch 

for one module in an enclosure. 

1.  Put the ICP-EZTS Tamper Switch (P/N: F01U009269) 

into the enclosure’s tamper switch mounting location. 

For complete instructions, refer to 

EZTS Cover and Wall 

Tamper Switch Installation Guide

 (P/N: F01U003734).

2.  Plug the tamper switch wire onto the module’s tamper 

switch connector.

3.3 | Attach to the control panel

Use either the module’s terminal strip labeled with PWR, A, B, 

and COM, or the module’s interconnect wiring connectors (wire 

included) to attach to the control panel. Interconnect wiring 

parallels the PWR, A, B, and COM terminals on the terminal 

strip. Refer to the following illustrations for wiring.

NOTICE!

Use the terminal strip wiring 

or

 interconnect wiring 

connector to the control panel. Do not use both. When 

connecting multiple modules, combine terminal strip 

and interconnect wiring connectors in series.

3 | Installation

Callout ― Description

1 ― Module with mounting bracket installed
2 ― Enclosure
3 ― Mounting screws (3)

Callout ― Description

1 ― Terminal strip wiring (SDI2)
2 ― Interconnect cable (P/N: F01U079745) (included)

Callout ― Description

1 ― Bosch control panel
2 ― B308 modules

Callout ― Description

1 ― Bosch control panel
2 ― B308 modules

CAUTION!

Remove all power (AC and battery) before making any 

connections. Failure to do so might result in personal 

injury and/or equipment damage.

NOTICE!

The module reads the switch setting only during 

power up. Cycle the power to the module to enable 

the new setting.

= Outputs 11 to 18

= Outputs 111 to 118

2.1 | Valid addresses and output numbers per

control panel

Valid B308 addresses are dependent on the number of outputs 

allowed by a particular control panel. 

Control 

panel

Valid B308 

addresses

Corresponding output 

numbers

B9512G

01 - 59

11 - 18, 21 - 28, 31 - 38, 41 - 

48, 51 - 58, 61 - 68, 71 - 78, 

81 - 88, 91 - 98, 101 - 108, 

111 - 118, 121 - 128, 131 - 

138, 141 - 148, 151 - 158, 

161 - 168, 171 - 178, 181 

- 188, 191 - 198, 201 - 208, 

211 - 218, 221 - 228, 

231 - 238, 241 - 248, 251 - 

258, 261 - 268, 271 - 278, 

281 - 288, 291 - 298, 301 

- 308, 311 - 318, 321 - 328, 

331 - 338, 341 - 348, 351 - 

358, 361 - 368, 371 - 378, 

381 - 388, 391 - 398, 401 

- 408, 411 - 418, 421 - 428, 

431 - 438, 441 - 448, 451 - 

458, 461 - 468, 471 - 478, 

481 - 488, 491 - 498, 501 

- 508, 511 - 518, 521 - 528, 

531 - 538, 541 - 548, 551 - 

558, 561 - 568, 571 - 578, 

581 - 588, 591 - 598

B8512G

01 - 09

11 - 18, 21 - 28, 31 - 38, 41 - 

48, 51 - 58, 61 - 68, 71 - 78, 

81 - 88, 91 - 98 

B6512

01 - 09

11 - 18, 21 - 28, 31 - 38, 41 - 

48, 51 - 58, 61 - 68, 71 - 78, 

81 - 88, 91 - 96

B5512

01 - 05

11 - 18, 21 - 28, 31 - 38, 

41 - 48, 51 - 58

B4512

01 - 03

11 - 18, 21 - 28, 31 - 38

D9412GV4

01 - 12

11 - 18, 21 - 28, 31 - 38, 

41 - 48, 51 - 58, 61 - 68, 

71 - 78, 81 - 88, 91 - 98, 

101 - 108, 111 - 118, 

121 - 128 

D7412GV4

01 - 06

11 - 18, 21 - 28, 31 - 38, 

41 - 48, 51 - 58, 61 - 64

D7212GV4

01 - 02

11 - 18, 21 - 24

To find the output numbers for each address, multiply the 

address number by 10 for the base number, and then use 

numbers 1 through 8 in the ones place for the output numbers. 

For examples, refer to 

Section 8

.

This module is a supervised device that provides 8 

programmable outputs (Form C relays) and connects to control 

panels through the SDI2 bus. 

Callout ― Description

1 ― SDI2 interconnect connectors - connect SDI2 control 

panel and SDI2 devices
2 ― SDI2 terminal strip - connect SDI2 control panel and 

SDI2 devices
3 ― Tamper switch connector
4 ― Terminal strip (outputs)
5 ― Heartbeat LED (blue)
6 ― Address switches