background image

 

 

 

 

 

AMAX panel

AMAX panel 2100 | AMAX panel 3000 | AMAX panel
3000 BE | AMAX panel 4000

 
 

en

Operation Manual

 

Summary of Contents for AMAX 4000

Page 1: ...AMAX panel AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel 4000 en Operation Manual ...

Page 2: ......

Page 3: ...with RADION RF keyfob 24 4 Changing the menu language 25 5 Changing date time and daylight saving time 26 6 System test 28 6 1 Siren test 28 6 2 Communication test 28 6 3 Walk test mode 28 7 Bypassing isolating 29 7 1 Bypassing unbypassing zones 29 7 1 1 How to bypass unbypass a zone via text keypad 29 7 1 2 How to bypass unbypass a zone via LED LCD keypad 29 7 1 3 How to view bypassed zones 30 7 ...

Page 4: ...tic dialing alarm 40 12 2 Confirming the domestic call 40 13 Event log recall mode 41 13 1 How to select all event log recall mode 41 13 2 How to select EN event log recall mode 41 13 3 How to select dialer event log recall mode 41 14 Faults and tamper conditions 42 14 1 System fault or tamper analysis mode via text keypad 42 14 2 System fault or tamper analysis mode via LED LCD keypad 42 15 Reset...

Page 5: ...r if you want to get your system modified Caution Sensitive components Damage of sensitive components is possible if the system is not handled carefully or if the system is opened or modified Always handle the system carefully Never open or modify the system Please contact your installer if you want to get your system modified 1 AMAX panel Safety en 5 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U...

Page 6: ...his and other modules and devices advanced settings and programming can be found in the Installation Manual Information on the main steps required for basic system installation and setup can be found in the Quick Installation Guide Technical data Frequency bands of operation Power level for radio equipment GSM900 Class 4 2W GPRS Class 33 GSM1800 Class 1 1W GPRS Class 33 UMTS2100 Class 3 0 25W Keyp...

Page 7: ...EXT The following LED LCD keypads can be used for operating AMAX panel 2100 3000 3000 BE 4000 IUI AMAX3 LED8 IUI AMAX3 LED16 AMAX panel Short information en 7 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U 295 569 ...

Page 8: ... and a description of the keypad indicator icons All keypad types Keypad Indicator Icons Status Definition AWAY on Area is armed in AWAY mode off Area is not armed in AWAY mode Slow flash 1 second lights on 1 second lights off Exit time 2 4 8 en Short information AMAX panel 2017 04 07 F 01U 295 569 Bosch Sicherheitssysteme GmbH ...

Page 9: ...n STAY mode Slow flash 1 second lights on 1 second lights off Exit time Fast flash 0 25 seconds lights on 0 25 seconds lights off System is in programming mode or code function mode AWAY indicator flashes simultaneously When bypass function is performed only the STAY indicator flashes Or One or more areas but not all are in STAY mode master keypad MAINS on AC main power is normal AMAX panel Short ...

Page 10: ... yet Or System is in service mode off System is in normal status Flashes System fault tamper bypassed zone or isolated zone condition must be acknowledged All icons Flashing No communication to the keypad Only for LED LCD Keypad Indicator Icons Status Definition 1 2 3 on Zone is triggered off Zone is normal 10 en Short information AMAX panel 2017 04 07 F 01U 295 569 Bosch Sicherheitssysteme GmbH ...

Page 11: ...r keypad Only for LCD Keypad Indicator Icons Status Definition on Area is disarmed The following table shows an overview and a description of the keypad sound icons Sound Indicator Definition Short beep A keypad button has been pressed Short beep followed by a one second beep The requested operation is refused Incorrect operation signal Two short beeps The system accepted the code The system execu...

Page 12: ...area is disarmed Quick keypad operations instructions The following table shows an overview of the quick keypad operations and the corresponding user permissions For information on changing codes and defining user permission levels refer to Codes page 36 Function Command Default code for user 1 2580 Default code for user 2 2581 D A B S M 2 M 1 I N Arm Disarm AWAY Arm code for 3 sec quick arm AWAY ...

Page 13: ...arm STAY Arm All Areas only on master keypad code 0 0 Direct STAY Arm only on master keypad code 2 digit area no Disarm code Disarm One Area only on a master keypad code 2 digit area no Disarm All Areas only on master keypad code Display Display Info Fault Tamper Analysis code 2 1 Bypass Isolate AMAX panel Short information en 13 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U 295 569 ...

Page 14: ...ne no code 3 1 cancel LED keypad Bypass Fault Tamper code 3 4 Inquire Bypass code 3 3 Isolate Unisolate Zone code 3 5 Inquire Isolate code 3 6 Reset Reset Fault Tamper In some country versions only the installer can reset a tamper alarm code 6 Macros Record Macro 1 code 8 1 sequence to be recorded for 3 sec 14 en Short information AMAX panel 2017 04 07 F 01U 295 569 Bosch Sicherheitssysteme GmbH ...

Page 15: ...Play Macro 2 code long press 2 2 for 3 sec quick macro Play Macro 3 code long press 3 3 for 3 sec quick macro Alarm commands Keypad Emergency Alarm long press 1 and 3 or and Keypad Fire long press 4 and 6 Keypad Medical Alarm long press 7 and 9 Other Commands Switch to Master Keypad code 0 0 0 only on text keypad Switch to Area 01 16 code 0 2 digit area no only on text keypad AMAX panel Short info...

Page 16: ...keypad Display Dialer Event Log code 2 4 only on text keypad Siren Test code 4 1 Communication Test code 4 2 Walk Test code 4 3 Change Date Time code 5 1 Daylight Saving Time 1h code 5 2 Daylight Saving Time 1h code 5 3 Add Change User Code code 5 4 Change Individual Code code 5 5 Call Back code 5 7 16 en Short information AMAX panel 2017 04 07 F 01U 295 569 Bosch Sicherheitssysteme GmbH ...

Page 17: ... code 7 2 disable System Reset code 9 9 8 9 D Duress User A Arming User B Basic User S Super User M1 Master User 1 M2 Master User 2 IN Installer This function can be enabled disabled individually for every user 4 For further information on codes refer to Add change user codes page 36 User menu The following table shows an overview of the user menu 2 6 AMAX panel Short information en 17 Bosch Siche...

Page 18: ...GS DAYL SAV TIME 1h DAYL SAV TIME 1h ADD CHG USER CODE SYSTEM TEST SIREN TEST COMMUNICATION TEST WALK TEST ALL EVENT RECALL EN EVENT RECALL DIAL EVENT RECALL EVENT PRINT PRINTER ENABLE RESET ZN FLT TAMP BYPASS ZONE BYPASS BYPASS INQUIRE BYPASS FLT TAMP INQUIRE ZN FAULT TAMP INQ ZONE ISOLATE ISOLATE INQUIRE USER MENU ARM DISARM ARM AWAY ARM STAY DISARM 18 en Short information AMAX panel 2017 04 07 ...

Page 19: ...tivated in a ready state Keypad arming There are two methods to arm the area assigned to your keypad in AWAY mode Method 1 4 Enter your code and press P The system beeps twice the AWAY indicator flashes slowly and exit time starts After the exit time the AWAY indicator is lit Method 2 quick arm 4 Press and hold until the system beeps twice P The AWAY indicator flashes slowly and exit time starts A...

Page 20: ...e press the 2 digit area number of the area to be armed and press P The AWAY indicator flashes slowly and exit time starts After the exit time the AWAY indicator is lit and the selected area is displayed as armed 4 Repeat if you want to arm multiple areas To enable disable this function contact your installer Telephone remote arming Notice Telephone remote arming is only possible when the system h...

Page 21: ...uld be intruder while at the same time being able to move freely within an area that is automatically isolated Keypad arming There are two methods to arm the area assigned to your keypad in STAY mode Method 1 4 Enter your code and press P The system beeps twice the STAY indicator flashes slowly and exit time starts After the exit time the STAY indicator is lit P The lights corresponding to all zon...

Page 22: ...ermission level master 1 or master 2 4 Enter your code press the 2 digit area number of the area to be armed and press P The STAY indicator flashes slowly and exit time starts After the exit time the STAY indicator is lit and the selected area is displayed as armed 4 Repeat if you want to arm multiple areas To enable disable this function contact your installer Key switch arming Users can use a ke...

Page 23: ...AWAY or STAY indicator is extinguished Disarming with a master keypad An optional master text keypad can be added if there is more than one assigned area on your system The master keypad can be used to disarm all assigned areas To enable disable this function contact your installer Disarming all areas 1 Enter your code and press 2 The system beeps twice and the AWAY or STAY indicator is extinguish...

Page 24: ...nction contact your installer Disarming with RADION RF keyfob 4 Press the disarming button of the RADION RF keyfob P The area is disarmed and the AWAY or STAY indicator is extinguished To enable disable this function contact your installer 3 2 3 3 2 4 24 en Arming and disarming areas AMAX panel 2017 04 07 F 01U 295 569 Bosch Sicherheitssysteme GmbH ...

Page 25: ... How to change the menu language 1 Enter your code 5 8 and press The available menu languages are displayed 2 Enter the two digit number for the desired language 3 Press P The system beeps twice and the menu language is changed 4 AMAX panel Changing the menu language en 25 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U 295 569 ...

Page 26: ... and press 2 Enter the date and the time and press The new date and time is set The DST OPTIONS menu is shown 3 If there is daylight saving time in your region select the setting for your region and press Or if your region is not listed Select 5 customize to individually configure the daylight saving time settings 4 Select START DST to determine when the daylight saving time setting should start a...

Page 27: ...9 Press three times to exit AMAX panel Changing date time and daylight saving time en 27 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U 295 569 ...

Page 28: ...ode This function allows users to test detection devices to ensure they are functioning correctly Bypass any zones that are not required for testing before activating the walk test mode During the walk test no walk test report is sent out to the control panel system How to select walk test mode 1 Enter your code 4 3 and press The system beeps twice and the STAY and AWAY indicators flash 2 Unseal a...

Page 29: ...e zones are marked with an x 2 Use and to display all zones 3 Select the zones you wish to bypass unbypass with The selected zones are checked unchecked 4 Press to confirm and exit How to bypass unbypass a zone via LED LCD keypad 1 Enter your code 3 1 and press The STAY indicator flashes slowly The slowly flashing number indicators show the bypassed zones If no numbers are lit no zones are bypasse...

Page 30: ...conditions are bypassed Isolating zones How to isolate unisolate a zone via text keypad 1 Enter your code 3 5 and press The STAY indicator flashes slowly The available zones are shown Already isolated zones are checked Unavailable zones are marked with an x 2 Use and to display all zones 3 Select the zones you wish to isolate unisolate with The selected zones are checked unchecked 4 Press to confi...

Page 31: ...eat step 2 if you want to isolate unisolate multiple zones 5 Press to exit How to view isolated zones 1 Enter your code 3 6 and press The system beeps twice and the isolated zones are displayed 2 Use and to display all isolated zones 3 Press to exit 7 3 3 AMAX panel Bypassing isolating en 31 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U 295 569 ...

Page 32: ...e deactivate a schedule 1 Enter your code until you reach SYSTEM SETTINGS 2 Press until you reach SCHEDULE ENABLE 3 Press 4 Select SCHED ENABLE and press The available schedules are shown Already selected schedules are checked 5 Use and to display all schedules 6 Enter the schedule number you wish to activate deactivate The selected schedule is checked unchecked 7 Repeat step 6 if you want to acti...

Page 33: ... which you want to assign the macro Possible numbers are 1 2 and 3 2 Press The system beeps twice 3 Perform the operation you want to assign to the macro 4 Press for three seconds to end the recording of the macro and to save it P The system beeps three times The macro is recorded and the operation is executed Example of recording a macro bypassing a zone This example shows how to assign macro 1 t...

Page 34: ... Method 1 4 Enter your code and press the number on which the macro is assigned for three seconds Possible numbers are 1 2 and 3 P The system beeps and the operation which is assigned to the macro is executed automatically Method 2 Quick Play 4 Press the number on which the macro is assigned for three seconds Possible numbers are 1 2 and 3 P The system beeps and the operation which is assigned to ...

Page 35: ...cros page 33 4 Enter your code and press 1 for three seconds The system beeps and the macro 1 is executed automatically P If zone 3 was unbypassed before playing macro 1 it is bypassed now P If zone 3 was bypassed before playing macro 1 it is unbypassed now AMAX panel Macros en 35 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U 295 569 ...

Page 36: ...a user number 1 64 for AMAX panel 2100 1 128 for AMAX panel 3000 and AMAX panel 3000 BE 1 250 for AMAX panel 4000 and press The current user permission level for this user is shown Default for user number 2 64 is 6 Not used 3 Select the desired user permission level You can choose the following user permission levels for a code 0 Master1 code 1 Master2 code 2 Super code 3 Basic code 4 Arming code ...

Page 37: ... 10 Repeat step 9 if you want to enable multiple areas for the user 11 Press 12 Enter a new code with a default length of four digits A code with five or six digits is also possible but has to be enabled by the installer 13 Press 14 Optionally enter a keyfob ID manually Or Press and hold for three seconds to switch to the KEYFOB ID AUTO menu Trigger the keyfob to give alarm once The keyfob ID will...

Page 38: ...dual user code 1 Enter your code 5 5 and press The system beeps twice and the STAY and AWAY indicators start flashing The current user code is displayed 2 Enter a new code with a default length of four digits A code with five or six digits is also possible but has to be enabled by the installer 3 Press P The system beeps twice and the STAY and AWAY indicators stop flashing The user code is changed...

Page 39: ...and hold 4 6 for three seconds P A silent keypad fire alarm is transmitted To enable disable this function contact your installer Keypad medical alarm 4 Press and hold 7 9 for three seconds P A silent keypad medical alarm is transmitted To enable disable this function contact your installer 11 11 1 11 2 11 3 AMAX panel Keypad alarm operation commands en 39 Bosch Sicherheitssysteme GmbH 2017 04 07 ...

Page 40: ...corded voice message The voice messages are recorded with A Link Plus and are transferred via A Link Plus to the AMAX panel To enable disable this function contact your installer Confirming the domestic call All alarm events need acknowledgement The transmission sequence is repeated until the control panel receives an acknowledgement tone The control panel automatically closes the line after 45 se...

Page 41: ...ce and the event logs are displayed 2 Use and to display all event logs 3 Press to exit How to select EN event log recall mode 1 Enter your code 2 3 and press The system beeps twice and EN event logs are displayed 2 Use and to display all EN event logs 3 Press to exit How to select dialer event log recall mode 1 Enter your code 2 4 and press The system beeps twice and dialer events are displayed 2...

Page 42: ...D LCD keypad How to display faults and tampers via a LED LCD keypad 1 Enter your code 2 1 and press The system beeps twice The FAULT indicator is extinguished and the STAY and AWAY indicators flash One of the number indicators is lit Example 2 2 Enter the number that is lit in the system Example 2 One of the number indicators is lit Example 1 3 Repeat step 2 until there is no number lit anymore 4 ...

Page 43: ...ule failure 1 2 1 2 Output expansion module 1 2 fault 1 3 Input expansion module failure 1 3 1 6 Input expansion module 1 6 failure 1 4 Printer failure 1 4 1 Module DX4010 missing 1 4 2 Printer missing 1 4 3 Printer fault 1 5 RF receiver failure 1 5 1 RF receiver 1 fault 1 5 2 RF receiver 1 missing 1 5 3 RF receiver 1 jammed 1 6 RF sensor failure 1 6 1 RF sensor missing 1 6 2 RF sensor fault AMAX ...

Page 44: ... 1 2 fault 2 4 Bosch option bus power failure 2 4 1 2 Bosch option bus 1 2 power fault 2 5 RF repeater AC power failure 2 5 1 8 RF repeater 1 8 AC power fault 2 6 RF repeater battery failure 2 6 1 8 RF repeater 1 8 battery fault 2 7 RF sensor power failure 2 8 RF keyfob battery failure 3 Output failure 3 1 Onboard output 1 fault 3 2 Onboard output 2 fault 4 Keypad failure 4 1 16 Keypad 1 16 failur...

Page 45: ...1 16 Keypad 1 16 tamper 7 3 Zone expansion module tamper 7 3 1 6 Zone expansion module 1 6 tamper 7 4 Zone tamper DEOL 7 4 1 16 Sensor tamper DEOL 7 5 Zone type tamper 7 5 1 16 Zone type 1 16 tamper 7 6 Keypad Lock out 7 6 1 Keypad Lock out 7 7 RF receiver tamper 7 7 1 RF receiver tamper 7 8 RF repeater tamper 7 8 1 8 RF repeater tamper AMAX panel Faults and tamper conditions en 45 Bosch Sicherhei...

Page 46: ...16 External fault zone 1 16 Table 14 1 Types of fault or tamper conditions In case one or more faults occur in this category 46 en Faults and tamper conditions AMAX panel 2017 04 07 F 01U 295 569 Bosch Sicherheitssysteme GmbH ...

Page 47: ...s Notice You can only reset alarms faults or tamper conditions when they are not active anymore How to reset the control panel 4 Enter your code 6 P The system beeps twice and the signal is eliminated 15 AMAX panel Resetting the control panel en 47 Bosch Sicherheitssysteme GmbH 2017 04 07 F 01U 295 569 ...

Page 48: ...Troubleshooting Please contact your installer in case of problems or any unexpected behavior of the system 16 48 en Troubleshooting AMAX panel 2017 04 07 F 01U 295 569 Bosch Sicherheitssysteme GmbH ...

Page 49: ......

Page 50: ......

Page 51: ......

Page 52: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2017 ...

Reviews: