background image

 

 
 
 
 
 
 

 

SCD110 Sense | Connect | Detect  
Operating Instructions / Version 2.0 

Summary of Contents for 262-SCD

Page 1: ...SCD110 Sense Connect Detect Operating Instructions Version 2 0 ...

Page 2: ...ial Notices 5 1 2 Definition of General Notices 5 2 Safety and Intended Use 5 2 1 Intended Use 6 2 2 Disposal 6 3 Introduction 6 3 1 Scope of Delivery 6 4 Technical Specification 7 4 1 Housing 7 4 2 Dimensions 7 4 3 Device Specifications 8 4 4 Operating Conditions 8 4 5 Sensors 8 4 6 Measurement Range and Accuracies 8 4 7 Resolution 8 4 8 Communication 9 4 9 User Interface 9 4 10 Communication Int...

Page 3: ...ld Setting 14 5 6 Streaming 14 5 7 Data on the Chart 15 5 7 1 Chart View Options 16 5 8 Logging and Transferring the Data 17 5 9 Removing the SCD 19 5 10 Reusing the SCD 19 6 General Operating Modes of SCD 20 6 1 General Behavior 20 6 2 Resetting the SCD 20 6 3 Streaming via Bluetooth Low Energy BLE 20 6 4 Logging Data into the Local Memory 20 6 4 1 Log File Format 21 6 5 Event Detection Mode 22 7...

Page 4: ...ion 24 10 1 Target Markets 24 10 2 European Union Notices 24 10 3 USA FCC Notices 25 10 4 Canada ISED Notices 25 10 5 IMDA Singapore Notices 25 10 6 ACMA Australia Notices 25 10 7 Japan Notice 26 10 8 South Africa Notice 26 10 9 Other Country Certifications 26 10 10 Bluetooth 26 10 11 Disposal 26 10 12 Restrictions of Use 26 10 13 Open Source License Condition 27 ...

Page 5: ... injuries Always follow these instructions Note Points of emphasis and reminders of device specific operational features that could affect the performance Always follow these instructions 1 2 Definition of General Notices 2 Safety and Intended Use Warning Do not open the housing Opening the housing without authorization will void any warranty and involves risk of injury to the user Using the SCD a...

Page 6: ...bility and criminal prosecution of the user Please see also the section 10 12 Restrictions of Use 2 2 Disposal Disposing of this product correctly will help save valuable resources and prevent any potential negative effects to human health and the environment which could otherwise arise from inappropriate waste handling Please contact a certified recycling company or the responsible local authorit...

Page 7: ...nsor cannot be guaranteed 4 Technical Specification 4 1 Housing The SCD is built from a robust housing suited for industrial use with a self adhesive back The compact design of the SCD fits perfectly in different industrial applications and enables easy user friendly mounting in difficult to access environments For mounting instructions please refer to 5 1 Mounting the SCD 4 2 Dimensions On button...

Page 8: ...ry Life up to 2 years depending on configuration and use Enclosure protection class IP 67 Electrical protection class III Sampling rates Hz Acceleration 400 800 1600 3200 6400 Magnetometer 10 Temperature 0 05 Light 1 25 10 Memory capacity 1 MB BLE Bluetooth Low Energy Activation In Standby On push button During operation Automatic activation every 3 hours Target markets and country certifications ...

Page 9: ...SCD can be integrated into any gateway BLE Bluetooth Low Energy V4 2 is currently supported The SCD always acts as a peripheral device to which other BLE devices like smartphones tablets gateways etc can establish a connection The BLE interface is used e g by a gateway or a mobile app to Configure the SCD Transfer data ATTRIBUTE VALUE Communication Bluetooth Low Energy BLE 4 2 Range up to 40 m dep...

Page 10: ... clean Mounting the SCD Peel off the protective film Stick SCD to the surface 5 2 Connecting to the SCD Download the SCD Sensor App The App is available for free in the Apple App Store or Google Play Store Please search for Bosch SCD or use the QR Codes below Apple App Store Google Play Store Activate Bluetooth on your smartphone To activate the SCD press shortly the button on the device Start the...

Page 11: ...S GM After you start the app the help screens offer you a short overview of the most important functions Please have a look After starting the app shows a search button Click on the search button to find devices TIP In order to select the right SCD when multiple are available move your smartphone tablet close to the desired SCD ...

Page 12: ...Tabs The App has different pages shown in the screenshot below a Help See help screens related to the area you are currently in b Disconnect Click on the Disconnect icon if you want to disconnect your device c Settings Rename your device and configure thresholds of the sensors d View Start stop data streaming See current values from the sensors e Diagram Show the streamed data in graphics f Loggin...

Page 13: ...on 1 0 BCDS GM 5 4 Configuring the SCD Tap on the Settings icon To ensure easy identification of your devices please rename your SCD by tapping on the pencil and typing in your preferred name Then tap Rename Note Only certain characters can be used for the device name The following characters are allowed A Z a z 0 9 _ ...

Page 14: ...ge with a red device icon Set the threshold values by tapping the Settings icon 5 6 Streaming The function transmits sensor values to the app at a fixed rate Values can be visualized and recorded in the View tab To start streaming enable the streaming button as shown in the screenshot below Tap on the streaming button to start data streaming The data is shown under the respective sensor icon In ca...

Page 15: ...ed in Germany September 20 Version 1 0 BCDS GM 5 7 Data on the Chart Tap on the Diagram icon Select the sensors you want to see in the chart by tapping the sensor icons The graphics and values are then displayed TIP In case of threshold violation the measurement values are shown in red ...

Page 16: ... the graph d Start stop Tap on this button to show freeze streaming data in the graph e Starts stops recording the streaming graph f Share the CSV of the last recorded session Note Please attention The data that you are recording in Diagram view is not the raw data coming from the sensors It is the data shown in the graphics For example Accelerometer values are aggregated to mean and variance valu...

Page 17: ...stores raw data in the SCD internal memory Data can be transmitted to the smartphone via SCD app or to the gateway over the BLE The logging settings can be configured by tapping on the Logging icon Set the desired sampling rates for each sensor which should be used by data logging Leave the sensors Disabled if you don t want to get data from them in the log file Tap on Start logging ...

Page 18: ...a subject not change without notice Printed in Germany September 20 Version 1 0 BCDS GM Confirm the logging start The data is stored locally in SCD until the memory is full or until the logging is stopped by the user The data is ready to download ...

Page 19: ...the embedded device SCD and transferred later In this way it is possible to save the data in high sampling rates Please don t use the recorded data in Diagram view which is aggregated to reduce the data volume in streaming 5 9 Removing the SCD 5 10 Reusing the SCD After the SCD has been removed it can be reused For mounting proceed as described in 5 1 Mounting the SCD Please note that after remova...

Page 20: ...and is able to initiate a connection By using BLE it is possible to configure the SCD and continuously receive measurement data The data can be visualized in the app or consumed in a gateway If the user wants to integrate the SCD into his her gateway the required document e g the SCD BLE Communication Protocol is publicly available in the website to download 6 4 Logging Data into the Local Memory ...

Page 21: ...sible Accelerometer Magnetometer Temperature and Light Unix TimeStamp ms It is the timestamp for the measurement stamped in SCD in UNIX timestamp format This is a total millisecond value that can be converted to a date and time Please search in internet for UNIX timestamp convertors for more details Data x_axis This is the first column of the data If the measurement is from accelerometer or magnet...

Page 22: ...t signal crosses the threshold an event is generated and signaled via BLE The app can show the threshold violations with red colored values The user can set thresholds in the app activate the streaming and disconnect In this case SCD will continue to threshold monitoring If there is a threshold violation detected this can be seen even in the advertisement message without connecting the SCD Note Wh...

Page 23: ...nsor is permanently at 0 Check if any additional label attached to the SCD These can cover the light sensor The protective cover is damaged Do not use the device None of the values are changing Is the sensor defect Check whether you have switched on streaming in the app Check if the sensor is activated Connection fails Make sure you get a user dialog asking for Pairing Make sure you accept pairing...

Page 24: ...t until 31 12 2020 United Kingdom Further countries USA Canada Columbia Singapore Japan South Africa Malaysia until 07Jan2021 10 2 European Union Notices European Union notices Radio Equipment Directive Bosch Connected Devices and Solutions GmbH hereby declares that the radio equipment type SCD110 is in compliance with Directive 2014 53 EU Radio Equipment Directive The full text of the EU declarat...

Page 25: ...as granted a technical acceptance certificate for the SCD110 under the ISED Certification number 12595A SCD110 The certification for Canada only applies to SCD110 devices with the IC ID printed on the housing The user shall verify before using the SCD110 in Canada Note This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 thi...

Page 26: ...ity com 10 10 Bluetooth The SCD110 has been granted the Bluetooth listing by the BT SIG 10 11 Disposal The unit embedded battery accessories and packaging should be sorted for environmental friendly recycling Do not dispose of the device into household and industrial waste According to the European Guideline 2012 19 EU electric and electronic devices that are no longer usable must be collected sep...

Page 27: ...open source software OSS components The OSS copyrights and license conditions are provided in the SCD Quick Start Guide that accompanies the device in the sales packaging For further assistance please refer to http www bosch connectivity com SCD or e mail support bosch connectivity com Bosch Connected Devices and Solutions GmbH Ludwig Erhard Straße 2 72760 Reutlingen Deutschland www bosch connecti...