TROUBLESHOOTING
Unit Fails to Jump-Start
• Make sure unit’s power switch is in the ON position.
• Check that Jump-Starter/Inflator has a full charge.
• Make sure a proper polarity cable connection has been established (see “Using
the Unit as a Jump-Starter,” page 3).
12 Volt Outlet Fails to Deliver Power
• Make sure a proper 12 volt adapter connection has been established.
• Check that the unit has a full charge.
12 Volt Outlet Shuts Off
Disconnect unit and allow to cool for 10 minutes.
Note:
When pulling more than 5 amps from the 12 volt outlet, unit will shut off.
LED Area Light Does Not Come On
• Check that the unit has a full charge.
SPECIFICATIONS
Jump-Start Clamps:
300 amps – heavy-duty copper
Jumper Cables:
#6 AWG welding cable
Instant Amps:
300
5 Second Amp:
225
Battery High Density AGM:
12 volt, 9 Ah, sealed, lead-acid
Worklight Bulb:
Long-life LED
Accessory Outlet Protection: 5 amps, self-resetting breaker