background image

POWER TO GO

®

INSTRUCTION MANUAL 

Thank you for choosing Black & Decker!

Go to www.BlackandDecker.com/NewOwner

to register your new product 

BEFORE RETURNING THIS PRODUCT

FOR ANY REASON PLEASE CALL

1-800-544-6986

BEFORE YOU CALL, HAVE THE CATALOG No, AND DATE CODE 

AVAILABLE. IN MOST CASES, A BLACK & DECKER REPRESENTATIVE

CAN RESOLVE THE PROBLEM OVER THE PHONE. IF YOU HAVE A

SUGGESTION OR COMMENT, GIVE US A CALL. YOUR FEEDBACK IS 

VITAL TO BLACK & DECKER.

Catalog Number CPI20XB

TO REDUCE THE RISK OF INJURY, THE USER MUST READ
AND UNDERSTAND THE INSTRUCTION MANUAL

SAVE THIS MANUAL FOR FUTURE REFERENCE.

Cat. # CPI20XB

Form # 90517191

April ’07  Copyright © 2007 Black & Decker 

Printed in China

CPI20XB_ManualEN_041307.qxp  6/25/07  2:07 PM  Page I

Summary of Contents for POWER TO GO CP120XB

Page 1: ...ATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER Catalog Number CPI20XB TO REDUCE THE RISK OF INJURY THE USER MUST READ AND UNDERSTAND THE INSTRUCTION MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Cat CPI20XB Form 90517191 April 07 Copyright 2...

Page 2: ...USE CORD Never carry appliance by cord or yank it to disconnect from receptacle Keep cord from heat oil and sharp edges DON T OVERREACH Keep proper footing and balance at all times DISCONNECT APPLIANCES Disconnect the appliance from the power supply when not in use before servicing and when changing accessories such as blades and the like AVOID UNINTENTIONAL STARTING Don t carry plugged in applian...

Page 3: ...ious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Used without the safety alert symbol indicates potentially hazardous situation which if not avoided may result in property damage WARNING RISK OF UNSAFE OPERATION When using tools or equipment basic safety precautions should always be followed to reduce the risk of pe...

Page 4: ...AC outlet The prongs of an AC plug can become bent from misuse If an AC plug is improperly inserted into the AC outlet a bent prong can slip outside the inverter and become a shock hazard WARNING EXPLOSION HAZARD This equipment employs components that tend to produce arcs or sparks DO NOT use in compartments containing batteries or flammable materials Use of an attachment not supplied recommended ...

Page 5: ...damaged if connected to the POWER TO GO Do not use the POWER TO GO with the following appliances a Small battery operated appliances like rechargeable flashlights some rechargeable shavers and night lights that are plugged directly into an AC receptacle to recharge b Battery chargers used in hand power tools These chargers display a warning label stating that dangerous voltages are present at the ...

Page 6: ...tts output for 5 minutes or 16 watts continuous 5 Volt DC USB Power Port Built in Power Fault LED Indicator Battery Status LED Indicators Rechargeable NiMH Battery Pack 120 Volt AC Charging Port and Charging Adapter Tethered Protective Outlet Covers Electronic circuit protection prevents damage due to overload insufficient ventilation overheat condition Compact size efficient and quiet USB POWER P...

Page 7: ...rm that has characteristics similar to the sine wave shape of utility power This type of waveform is suitable for most AC loads including linear and switching power supplies used in electronic equipment transformers and small motors The modified sine wave produced by this inverter has an RMS root mean square voltage of 115 volts Most AC voltmeters both digital and analog are sensitive to the avera...

Page 8: ...ipment simultaneously plugged into the CPI20XB does not exceed 16 watts continuous 120 Volt AC Outlet 1 Make sure the CPI20XB is properly charged Turn the unit to the ON position All Status LED Indicators will be lit solid indicating proper operation of the unit and battery capacity 2 Plug the 110 120 volt AC appliance into the Inverter s two prong AC outlet and operate normally Note The CPI20XB w...

Page 9: ... automatically shut down when the unit becomes overheated Manual reset will be necessary after the unit cools down to restart unit Overload Short Circuit Protection the inverter will automatically shut down when a short circuit occurs Manual reset will be necessary to restart unit Note The Bi color Inverter Status LED Indicator will light red to indicate Fault condition before automatic shutdown o...

Page 10: ...ll no longer retain a charge For information on recycling this battery call toll free 877 822 8837 WARNINGS TO REDUCE THE RISK OF INJURY EXPLOSION Do not dispose of batteries in fire as this may result in an explosion Do not expose the unit containing a battery to fire or intense heat as it may explode TROUBLESHOOTING Common Audio Visual Problems Problem Buzzing Sound In Audio Systems Some inexpen...

Page 11: ... overload or and green Battery Status LEDs are lit fault condition attempt manual but there is no AC power reset and reduce load LED indicators are off Hold ON OFF pushbutton for at unit may not be in the ON position least 1 second to turn unit ON Unit shuts down after a few Internal battery pack needs minutes internal battery voltage recharging refer to charging is low instructions on page 7 Comm...

Page 12: ...turn the product to the retailer from whom it was purchased provided that the store is a participating retailer Returns should be made within the time period of the retailer s policy for exchanges usually 30 to 90 days after the sale Proof of purchase may be required Please check with the retailer for their specific return policy regarding returns that are beyond the time set for exchanges The sec...

Page 13: ... Output 115 V AC 60Hz 20 watts for 5 minutes 16 watts continuous USB Output 5 V DC 350mA Batteries 1 2 AH NiMH Imported by Black Decker U S Inc 701 E Joppa Rd Towson MD 21286 U S A Vector Products Inc 4140 SW 28th Way Fort Lauderdale FL 33312 12 ...