FWS-2273 

 

Desktop  Network  Appliance 

 

User’s  Manual  2

nd

  Ed

Summary of Contents for Aaeon FWS-2273

Page 1: ...FWS 2273 Desktop Network Appliance User s Manual 2nd Ed ...

Page 2: ...ded in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties that may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to a...

Page 3: ...ed trademark of Microsoft Corp Intel Pentium Celeron and Xeon are registered trademarks of Intel Corporation Core Atom are trademarks of Intel Corporation ITE is a trademark of Integrated Technology Express Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Corporation All other product names or trademarks are properties of their respective owners ...

Page 4: ...ng up your product please make sure the following items have been shipped Item Quantity FWS 2273 1 SATA cable 1 SATA power cable 1 Power adapter 1 Rubber foot 4 If any of these items are missing or damaged please contact your distributor or sales representative immediately ...

Page 5: ...as detailed descriptions and explanations on the product s hardware and software features if any its specifications dimensions jumper connector settings definitions and driver installation instructions if any to facilitate users in setting up their product Users may refer to the AAEON com for the latest version of this document ...

Page 6: ...the system s hardware 6 No connections should be made when the system is powered as a sudden rush of power may damage sensitive electronic components 7 If the device is not to be used for a long time disconnect it from the power supply to avoid damage by transient over voltage 8 Always disconnect this device from any AC supply before cleaning 9 While cleaning use a damp cloth instead of liquid or ...

Page 7: ...iners 18 If any of the following situations arises please the contact our service personnel i Damaged power cord or plug ii Liquid intrusion to the device iii Exposure to moisture iv Device is not working as expected or in a manner as described in this manual v The device is dropped or damaged vi Any obvious signs of damage displayed on the device 19 DO NOT LEAVE THIS DEVICE IN AN UNCONTROLLED ENV...

Page 8: ...explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions and your local government s recycling or disposal directives Attention Il y a un risque d explosion si la batterie est remplacée de façon incorrecte Ne la remplacer qu avec le même modèle ou équivalent ...

Page 9: ... Box PC Industrial System 部件名称 有毒有害物质或元素 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 印刷电路板 及其电子组件 外部信号 连接器及线材 外壳 中央处理器 与内存 硬盘 电源 O 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ T 11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T 11363 2006 标准规定的限量要求 备注 一 此产品所标示之环保使用期限 系指在一般正常使用状况下 二 上述部件物质中央处理器 内存 硬盘 光驱 触控模块为选购品 ...

Page 10: ... O O O O O Wires Connectors for External Connections O O O O O O Chassis O O O O O O CPU RAM O O O O O O Hard Disk O O O O O O PSU O O O O O O O The quantity of poisonous or hazardous substances or elements found in each of the component s parts is below the SJ T 11363 2006 stipulated requirement X The quantity of poisonous or hazardous substances or elements found in at least one of the component...

Page 11: ...Connectors 24 2 4 1 Digital I O CN6 26 2 4 2 Front Panel Pin Head CN4 26 2 5 2 5 Hard Disk Drive Installation 27 2 6 Mini PCIe Card Installation 33 Chapter 3 AMI BIOS Setup 35 3 1 System Test and Initialization 36 3 2 AMI BIOS Setup 37 3 3 Setup Submenu Main 38 3 4 Setup Submenu Advanced 39 3 4 1 Advanced Trusted Computing 40 3 4 2 Advanced CPU Configuration 42 3 4 3 Advanced SATA Drives 43 3 4 4 ...

Page 12: ...ter 4 Driver Installation 66 4 1 Driver Installation 67 Appendix A Watchdog Timer Programming 68 A 1 Watchdog Timer Initial Program 69 Appendix B I O Information 75 B 1 I O Address Map 76 B 2 Memory Address Map 78 B 3 IRQ Mapping Chart 80 Appendix C Standard LAN Bypass Platform Setting 89 C 1 Introduction to LED 90 C 1 1 Status LED Configuration 91 C 1 2 Sample Code 92 C 2 Introduction to LAN Bypa...

Page 13: ...Desktop Network Appliance FWS 2273 Chapter 1 Chapter 1 Product Specifications ...

Page 14: ...with Intel i210 Gigabit Ethernet x 6 Copper x 4 SFP x 2 Bypass Supports up to 2 pairs bypass function Storage 2 5 HDD bay x 1 CompactFlash socket x 1 Expansion Interface Mini Card socket full size with SIM socket x 2 USB 3 0 Type A on I O side x 2 2 5 USB2 0 pin header x 1 OS Support Yocto Tool based Embedded Linux 4 1 or above VGA Chipset LAN Front Panel I O Power LED x 1 Status LED x 1 HDD Activ...

Page 15: ... RTC Watchdog Timer 1 255 steps by software programming Software Button GPIO Programmable push button x 1 TPM Optional TPM v1 2 9660 TPM2 0 9665 GPIO Reserve internal pin header 8 bit Digital I O interface 4 in 4 out Fan System Fan x 1 Color Black Power Supply DC 40W power input Power Requirement DC 12V power jack Dimension W x D x H 220 x 105 x 44mm Certification CE FCC Class A Display Graphic En...

Page 16: ...nmental Operating Temperature 0 40 C 32 104 F Storage Temperature 20 60 C 4 104 F Operating Humidity 10 80 relative humidity non condensing Storage Humidity 10 80 40 C non condensing Anti Vibration 0 5 Grms 5 500Hz operation 2 5 HDD 1 5 Grms 5 500Hz non operation Anti Shock 10 G peak acceleration 11m sec duration operation 20 G peak acceleration 11m sec duration non operation ...

Page 17: ...Desktop Network Appliance FWS 2273 Chapter 2 Chapter 2 Hardware Information ...

Page 18: ...Chapter 2 Hardware Information 18 Network Appliance FWS 2273 2 1 Dimensions System ...

Page 19: ...Chapter 2 Hardware Information 19 Network Appliance FWS 2273 Board Component Side Solder Side ...

Page 20: ...Chapter 2 Hardware Information 20 Network Appliance FWS 2273 2 2 Jumpers and Connectors Component Side ...

Page 21: ...Chapter 2 Hardware Information 21 Network Appliance FWS 2273 Solder Side ...

Page 22: ...ork Appliance FWS 2273 2 3 List of Jumpers Please refer to the table below for all of the board s jumpers that you can configure for your application Label Function JP1 CF POWER Selection JP2 Auto PWRBTN Selection CN1 CMOS Setting Selection ...

Page 23: ...pliance FWS 2273 2 3 1 CFD Voltage 3 3V 5V Selection JP1 5V 3 3V Default 2 3 2 Auto PWRBTN Selection JP2 Don t use Auto PWRBTN Default Use Auto PWRBTN 2 3 3 CMOS Setting Selection CN1 Normal Default Clear CMOS 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 ...

Page 24: ...N1 4P SMART FAN CON1 COM PORT CN12 SATA6G INTERFACE CN9 SATA POWER CN13 Mini PCIe socket Only USB2 0 CN30 Mini PCIe socket CN31 CF CARD SOCKET CN11 CN29 SIM CARD SOCKET CN18 RESET CN19 SW1 POWER BUTTON CN21 USB3 0 DUAL Port CN6 Digital I O CN22 LAN1 4 RJ45 Type SFP1 LAN5 SFP Type SFP2 LAN6 SFP Type CN7 USB2 0 DUAL Port Pin Head SW2 Software Reset CN3 Battery Socket CN4 Front Panel pin head LED1 PO...

Page 25: ...Chapter 2 Hardware Information 25 Network Appliance FWS 2273 LED4 LED7 RJ45 LAN Link Stats LED LED9 LED10 SFP LAN Link Stats LED ...

Page 26: ...n Signal 1 Digital IN OUT Port1 Bit 1 2 Digital IN OUT Port1 Bit 2 3 Digital IN OUT Port1 Bit 4 4 Digital IN OUT Port1 Bit 5 5 Digital IN OUT Port3 Bit 4 6 Digital IN OUT Port3 Bit 5 7 Digital IN OUT Port6 Bit 3 8 Digital IN OUT Port4 Bit 7 9 5V 10 GND 2 4 2 Front Panel Pin Head CN4 Pin Signal Pin Signal 1 GND 2 POWER LED 3 HDD LED 4 HDD LED 5 BPLED1 6 BPLED1 7 BPLED2 8 BPLED2 9 Stats Led Red 10 S...

Page 27: ...r 2 Hardware Information 27 Network Appliance FWS 2273 2 5 2 5 Hard Disk Drive Installation 1 Loosen the screw and remove the top case from the lower side 2 Loosen the screw and remove the mother board module ...

Page 28: ...Chapter 2 Hardware Information 28 Network Appliance FWS 2273 3 Loosen the four screws and remove the mother board 4 Put the assembled cushions on the hard disk driver bracket ...

Page 29: ...Chapter 2 Hardware Information 29 Network Appliance FWS 2273 5 Lock the HDD onto the cushions with the four screws ...

Page 30: ...rk Appliance FWS 2273 6 Connect the SATA cable and power cable into the Hard Disk and lock in the cable with the cable ties 7 Connect the SATA cable and the power cable onto the mother board and lock in the mother board with the four screws ...

Page 31: ...Chapter 2 Hardware Information 31 Network Appliance FWS 2273 8 Put the assembled mother board module onto the bottom case and lock the screw 9 Put the assembled top case onto the bottom case ...

Page 32: ...Chapter 2 Hardware Information 32 Network Appliance FWS 2273 10 Lock the screw ...

Page 33: ...Chapter 2 Hardware Information 33 Network Appliance FWS 2273 2 6 Mini PCIe Card Installation 1 Unscrew the Mini PCIe card cover lid 2 Push the Mini PCIe card into the slot ...

Page 34: ...Chapter 2 Hardware Information 34 Network Appliance FWS 2273 3 Lock down the Mini PCIe card with the screw 4 Lock down the Mini PCIe card cover with the screw ...

Page 35: ...Desktop Network Appliance FWS 2273 Chapter 3 Chapter 3 AMI BIOS Setup ...

Page 36: ...red in the CMOS memory and BIOS NVRAM If system configuration is not found or system configuration data error is detected system will load optimized default and re boot with this default system configuration automatically There are four situations in which you will need to setup system configuration 1 You are starting your system for the first time 2 You have changed the hardware attached to your ...

Page 37: ...en the power is turned off To enter BIOS Setup press Del or F2 immediately while your computer is powering up The function for each interface can be found below Main Date and time can be set here Press Tab to switch between date elements Advanced Enable Disable boot option for legacy network devices Chipset For hosting bridge parameters Security The setup administrator password can be set here Boo...

Page 38: ...Chapter 3 AMI BIOS Setup 38 Network Appliance FWS 2273 3 3 Setup Submenu Main ...

Page 39: ...Chapter 3 AMI BIOS Setup 39 Network Appliance FWS 2273 3 4 Setup Submenu Advanced ...

Page 40: ... TCG EFI protocol and INT1A interface will not be available SHA 1 PCR Bank Disabled Enabled Enable or Disable SHA 1 PCR Bank SHA256 PCR Bank Disabled Enabled Enable or Disable SHA256 PCR Bank Pending operation None TPM Clear Schedule an Operation for the Security Device NOTE Your Computer will reboot during restart in order to change State of Security Device Platform Hierarchy Disabled Enabled Ena...

Page 41: ..._2 the Compatible mode for Win8 Win10 TCG_2 Support new TCG2 protocol and event format for Win10 or later Physical Presence Spec Version 1 2 1 3 Select to Tell O S to support PPI Spec Version 1 2 or 1 3 Note some HCK tests might not support 1 3 Device Select TPM 1 2 TPM 2 0 Auto TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restrict support to TPM 2 0 devices Auto will support both...

Page 42: ... Virtualization Technology Disabled Enabled When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology VT d Disabled Enabled Enable Disable CPU VT d EIST Disabled Enabled Enable Disable Intel SpeedStep Power Limit 1 Enable Disabled Enabled Enable Disable Power Limit 1 ...

Page 43: ...ppliance FWS 2273 3 4 3 Advanced SATA Drives Options summary Chipset SATA Disabled Enabled Enables or Disables the Chipset SATA Controller The Chipset SATA controller supports the 2 black internal SATA ports up to 3Gb s supported per port ...

Page 44: ...3 3 4 4 Advanced USB Configuration Options summary Legacy USB Support Disabled Enabled Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications ...

Page 45: ...ed FAN is always running with full speed Fan Control Mode Automatic Mode Manual Mode Manual Mode Depends on PWM Duty Automatic Mode FAN Speed is depends on System Temperature Spin PWM 100 0 255 The PWM Duty of FAN Spin Range 0 255 Off Control Temperature 30 0 127 Temperature Limit Value of Fan Off Note Some fans have the minimum speed even if the PWM value is 0 Start Control Temperature 50 0 127 T...

Page 46: ...Chapter 3 AMI BIOS Setup 46 Network Appliance FWS 2273 Full Speed Temperature 80 Temperature Limit Value of FAN Full Speed PWM Slope 5 1 15 Slope PWM value Degree C for FAN Speed Control Range 1 15 ...

Page 47: ...Chapter 3 AMI BIOS Setup 47 Network Appliance FWS 2273 3 4 6 Advanced SIO Configuration ...

Page 48: ...l Port Configuration Options summary Use This Device Disabled Enabled Enable or Disable this Logical Device Possible Use Automatic Settings IO 2F8h IRQ 3 IO 3F8h IRQ 4 Allows user to change Device s Resource settings New settings will be reflected on This Setup Page after System restarts ...

Page 49: ... 3 AMI BIOS Setup 49 Network Appliance FWS 2273 3 4 6 1 1 Serial Port Configuration Serial Port Console Redirection Options summary Console Redirection Disabled Enabled Console Redirection Enabled or Disabled ...

Page 50: ...Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes Bits per second 9600 19200 38400 57600 115200 Selects serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Data Bits 7 8 Data Bits ...

Page 51: ...w control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals VT UTF8 Combo Key Support Disabled Enabled Enable VT UTF8 Combination Key Support for ANSI VT100 terminals R...

Page 52: ...rk Appliance FWS 2273 The Setting Specify if BootLoader is selected than Legacy console redirection is disabled before booting to Legacy OS Default value is Always Enable which means Legacy console Redirection is enabled for Legacy OS ...

Page 53: ...s the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Settings page for more Help with Terminal Type Emulation Bits per second 9600 19200 57600 115200 Selects serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Flow Control None Hardware RTS CTS Softw...

Page 54: ... 7 8 Data Bits Parity None Even Odd Mark Space A parity bit can be sent with the data bits to detect some transmission errors Even parity bit is 0 if the num of 1 s in the data bits is even Odd parity bit is 0 if num of 1 s in the data bits is odd Mark parity bit is always 1 Space Parity bit is always 0 Mark and Space Parity do not allow for error detection Stop Bits 1 2 Stop bits indicate the end...

Page 55: ...F RED LED ON RED LED BLINK RED LED FAST BLINK GREEN LED ON GREEN LED BLINK GREEN LED FAST BLINK Configure LAN Bypass Status LED LAN kit Power ON Bypass PassTru Setting LAN kit function behavior when power on Bypass Pass Through LAN kit Power Off Bypass PassTru Setting LAN kit function behavior when power off Bypass Pass Through ...

Page 56: ...Chapter 3 AMI BIOS Setup 56 Network Appliance FWS 2273 WDT configuration Force Bypass SystemReset Configure WDT behavior System Reset Force Bypass ...

Page 57: ... is re applied after a power failure RTC Wake system from S5 Disabled Fixed time Dynamic time Fixed Time System will wake on the hr min sec specified Dynamic Time System will wake on the current time Increase minute s Wake up day Fixed time option 0 Select 0 for daily system wake up 1 31 for which day of month that you would like the system to wake up Wake up hour Fixed time option 0 Select 0 23 F...

Page 58: ...Chapter 3 AMI BIOS Setup 58 Network Appliance FWS 2273 Wake up minute Fixed time option 0 0 59 Wake up second Fixed time option 0 0 59 Wake up minute increase Dynamic time option 1 1 5 ...

Page 59: ...etwork Appliance FWS 2273 3 4 8 Digital IO Port Configuration DIO_P 1 4 Input Output Set DIO as Input or Output DIO_P 5 8 Input Output Set DIO as Input or Output DIO_P 1 4 Direction Low High Set output level when DIO pin is output ...

Page 60: ...Chapter 3 AMI BIOS Setup 60 Network Appliance FWS 2273 3 5 Setup submenu Chipset ...

Page 61: ...Chapter 3 AMI BIOS Setup 61 Network Appliance FWS 2273 3 5 1 Chipset North Bridge Options summary Primary Display IGD PCIe Select which of IGD PCI Graphics device should be Primary Display ...

Page 62: ...Chapter 3 AMI BIOS Setup 62 Network Appliance FWS 2273 3 5 1 1 North Bridge AMI Graphic Output Protocol Policy Options summary Output Select HDMI1 Output Interface ...

Page 63: ...ghlight these items and press Enter a dialog box appears which lets you enter a password You can enter no more than six letters or numbers Press Enter after you have typed in the password A second dialog box asks you to retype the password for confirmation Press Enter after you have retyped it correctly The password is required at boot time or when the user enters the Setup utility Removing the Pa...

Page 64: ...MI BIOS Setup 64 Network Appliance FWS 2273 3 7 Setup submenu Boot Options summary Quite Boot Disabled Enabled Enables or disables Quiet Boot option Network Stack Disabled Enabled Enable Disable UEFI Network Stack ...

Page 65: ...Chapter 3 AMI BIOS Setup 65 Network Appliance FWS 2273 3 8 Setup submenu Exit ...

Page 66: ...Desktop Network Appliance FWS 2273 Chapter 4 Chapter 4 Driver Installation ...

Page 67: ...e drivers and utilities you need to setup your product Follow the steps below to install the drivers http www aaeon com en p desktop network appliance fws 2273 Step 1 Open the Step 1 LAN folder and select the OS folder your system is Step 2 Double click on igb 5 3 5 4 tar file and follow the README instructions Step 3 Drivers can then be installed ...

Page 68: ...Desktop Network Appliance FWS 2273 Appendix A Appendix A Watchdog Timer Programming ...

Page 69: ...nP Mode Data Register 0x2F or 0x4F Table 2 Watchdog relative register table LDN Register BitNum Value Note Timer Counter 0x07 Note3 0x73 Note4 Note24 Time of watchdog timer 0 255 This register is byte access Counting Unit 0x07 Note5 0x72 Note6 7 Note7 1 Note8 Select time unit 1 second 0 minute Watchdog Enable KRST 0x07 Note9 0x72 Note10 6 Note11 1 Note1 2 0 Disable 1 Enable Timeout Status 0x07 Not...

Page 70: ... This parameter is represented from Note24 define byte UnitLDN This parameter is represented from Note5 define byte UnitReg This parameter is represented from Note6 define byte UnitBit This parameter is represented from Note7 define byte UnitVal This parameter is represented from Note8 define byte EnableLDN This parameter is represented from Note9 define byte EnableReg This parameter is represente...

Page 71: ...twork Appliance FWS 2273 VOID Main Procedure AaeonWDTConfig byte Timer Time of WDT timer 0x00 0xFF boolean Unit Select time unit 0 second 1 minute AaeonWDTConfig Procedure AaeonWDTEnable This procudure will enable the WDT counting AaeonWDTEnable ...

Page 72: ...nableReg EnableBit 0 Clear Watchdog Timeout Status WDTClearTimeoutStatus WDT relative parameter setting WDTParameterSetting VOID WDTEnableDisable byte LDN byte Register byte BitNum byte Value SIOBitSet LDN Register BitNum Value VOID WDTParameterSetting Watchdog Timer counter setting SIOByteSet TimerLDN TimerReg TimerVal WDT counting unit setting SIOBitSet UnitLDN UnitReg UnitBit UnitVal VOID WDTCl...

Page 73: ...x 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0x55 Break Case 0x4E IOWriteByte SIOIndex 0x87 IOWriteByte SIOIndex 0x01 IOWriteByte SIOIndex 0x55 IOWriteByte SIOIndex 0xAA Break VOID SIOExitMBPnPMode IOWriteByte SIOIndex 0x02 IOWriteByte SIOData 0x02 VOID SIOSelectLDN byte LDN IOWriteByte SIOIndex 0x07 SIO LDN Register Offset 0x07 IOWriteByte SIOData LDN ...

Page 74: ...e SIOEnterMBPnPMode SIOSelectLDN byte LDN IOWriteByte SIOIndex Register TmpValue IOReadByte SIOData TmpValue 1 BitNum TmpValue Value BitNum IOWriteByte SIOData TmpValue SIOExitMBPnPMode VOID SIOByteSet byte LDN byte Register byte Value SIOEnterMBPnPMode SIOSelectLDN LDN IOWriteByte SIOIndex Register IOWriteByte SIOData Value SIOExitMBPnPMode ...

Page 75: ...Desktop Network Appliance FWS 2273 Appendix B Appendix B I O Information ...

Page 76: ...Appendix B I O Information 76 Network Appliance FWS 2273 B 1 I O Address Map ...

Page 77: ...Appendix B I O Information 77 Network Appliance FWS 2273 ...

Page 78: ...Appendix B I O Information 78 Network Appliance FWS 2273 B 2 Memory Address Map ...

Page 79: ...Appendix B I O Information 79 Network Appliance FWS 2273 ...

Page 80: ...Appendix B I O Information 80 Network Appliance FWS 2273 B 3 IRQ Mapping Chart ...

Page 81: ...Appendix B I O Information 81 Network Appliance FWS 2273 ...

Page 82: ...Appendix B I O Information 82 Network Appliance FWS 2273 ...

Page 83: ...Appendix B I O Information 83 Network Appliance FWS 2273 ...

Page 84: ...Appendix B I O Information 84 Network Appliance FWS 2273 ...

Page 85: ...Appendix B I O Information 85 Network Appliance FWS 2273 ...

Page 86: ...Appendix B I O Information 86 Network Appliance FWS 2273 ...

Page 87: ...Appendix B I O Information 87 Network Appliance FWS 2273 ...

Page 88: ...Appendix B I O Information 88 Network Appliance FWS 2273 ...

Page 89: ...Desktop Network Appliance FWS 2273 Appendix C Appendix C Standard LAN Bypass Platform Setting ...

Page 90: ... Bypass Platform Setting 90 Network Appliance FWS 2273 C 1 Introduction to LED FWS 2273 provides a LED indicator which can change the LED status by AAEON SDK User is able to program the LED status to express different status ...

Page 91: ...D Status STA_LED2 STA_LED1 STA_LED0 LED Off 0 0 0 Red 0 0 1 Red Blinking Slowly 0 1 0 Red Blinking Quickly 0 1 1 Reserved 1 0 0 Green Blinking Slowly 1 0 1 Green Blinking Quickly 1 1 0 Green 1 1 1 Table2 Status LED and register mapping table CPLD Slave Address 0x90 Note1 Attribute Offset SMBUS BitNum Value STA_LED2 R W 0x00 Note2 2 Table 1 STA_LED1 R W 0x00 Note2 1 Table 1 STA_LED0 R W 0x00 Note2 ...

Page 92: ... This parameter is represented from Note2 bData aaeonSmbusReadByte CPLD_SLAVE_ADDRESS OFFSET switch LED_FLAG case 0 LED Off BIT2 0 BIT1 0 BIT0 0 bData bData 0xF8 break case 1 Red LED On BIT2 0 BIT1 0 BIT0 1 bData bData 0xF8 0x01 break case 2 Red LED Blink BIT2 0 BIT1 1 BIT0 0 bData bData 0xF8 0x02 break case 3 Red LED Fast Blink BIT2 0 BIT1 1 BIT0 1 bData bData 0xF8 0x03 break case 4 ...

Page 93: ...2273 Green LED On BIT2 1 BIT1 1 BIT0 1 bData bData 0xF8 0x07 break case 5 Green LED Blink BIT2 1 BIT1 0 BIT0 1 bData bData 0xF8 0x05 break case 6 Green LED Fast Blink BIT2 1 BIT1 1 BIT0 0 bData bData 0xF8 0x06 break default break SmbusWriteByte CPLD_SLAVE_ADDRESS 0x00 bData ...

Page 94: ...d LAN Bypass Platform Setting 94 Network Appliance FWS 2273 C 2 Introduction to LAN Bypass FWS 2273 provides LAN Bypass kit and allow uninterrupted network traffic even if a single in line appliance is shut down or hangs ...

Page 95: ...able of LAN kit They should be set before ACT_EN LAN_ID2 LAN_ID1 LAN_ID0 PWR_ON Use for configuring LAN Bypass function behavior to LAN kit when system power on 1 Bypass 0 Pass Through PWR_OFF Use for configuring LAN Bypass function behavior to LAN kit when system power off 1 Bypass 0 Pass Through WDT_EN Use for configuring WDT function behavior to LAN kit when WDT triggered 0 Normal WDT reset Def...

Page 96: ...D Slave Address 0x90 Note1 Attribute Offset SMBUS BitNum Value LAN_ID3 R W 0x01 Note2 3 Table 1 LAN_ID2 R W 0x01 Note2 2 Table 1 LAN_ID1 R W 0x01 Note2 1 Table 1 LAN_ID0 R W 0x01 Note2 0 Table 1 PWR_ON R W 0x01 Note2 6 Table 2 PWR_OFF R W 0x01 Note2 5 Table 2 WDT_EN R W 0x01 Note2 4 Table 2 ACT_EN R W 0x01 Note2 7 Table 2 ...

Page 97: ...dByte CPLD_SLAVE_ADDRESS OFFSET Set Reg01h bit3 if bLanSel 0x08 bData bData 0x08 else bData bData 0xF7 Set Reg01h bit2 if bLanSel 0x04 bData bData 0x04 else bData bData 0xFB Set Reg01h bit1 if bLanSel 0x02 bData bData 0x02 else bData bData 0xFD Set Reg01h bit0 if bLanSel 0x01 bData bData 0x01 else bData bData 0xFE Power On Action Reg01h bit6 if SET_PASS_THROUGH Pass Through bData bData 0xBF else B...

Page 98: ...if SET_WDT_RESET Reset bData bData 0xEF else Bypass bData bData 0x10 SmbusWriteByte CPLD_SLAVE_ADDRESS OFFSET bData Apply Settings Reg01h bit7 bData SmbusReadByte CPLD_SLAVE_ADDRESS OFFSET SmbusWriteByte CPLD_SLAVE_ADDRESS OFFSET bData 0x7F Sleep 500 bData SmbusReadByte CPLD_SLAVE_ADDRESS OFFSET SmbusWriteByte CPLD_SLAVE_ADDRESS OFFSET bData 0x80 ...

Page 99: ...dix C Standard LAN Bypass Platform Setting 99 Network Appliance FWS 2273 C 3 Introduction to Software Reset Button Configuration FWS 2273 provides a general propose input button which status get by AAEON SDK ...

Page 100: ... Bypass relative register table Function Description BTN_STS Reading this register returns the pin level status which is normal high active low 0 Pin Level States Low 1 Pin Level States High Table 1 Soft Reset Button register mapping table Attribute Register I O BitNum Value Attribute BTN_STS R 0xA05 Note1 4 Note2 Note3 BTN_STS ...

Page 101: ...fine Word BTN_STS This parameter is represented from Note1 define ByteBTN_STS_R This parameter is represented from Note2 Byte GET_Value Word IoAddr Byte BitNum Byte Value BYTE TmpValue TmpValue inportb IoAddr return TmpValue 1 BitNum VOID Main Byte RstBtn RstBtn GET_Value BTN_STS BTN_STS_R Active Low ...