background image

10 Gigabit/s Ethernet 
10GBASE-T Dual Port 

PEB-10G/57840-2T

User Guide

Summary of Contents for 57840-2T

Page 1: ...10 Gigabit s Ethernet 10GBASE T Dual Port PEB 10G 57840 2T User Guide ...

Page 2: ...RCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL ASUS ITS DIRECTORS OFFICERS EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING DAMAGES FOR LOSS OF PROFITS LOSS OF BUSINESS LOSS OF USE OR DATA INTERRUPTION OF BUSINESS AND THE LIKE EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN...

Page 3: ...ts 1 2 1 3 System requirements 1 2 1 4 Card layout 1 3 1 5 Replacing the card bracket 1 4 Chapter 2 Boot Agent Configuration 2 1 Broadcom NetXtreme Ethernet Boot Agent 2 2 2 1 1 Device Hardware Configuration Menu 2 3 2 1 2 MBA Configuration Menu 2 4 2 1 3 iSCSI Boot Configuration 2 5 2 1 4 NIC Partition Configuration Menu 2 8 Chapter 3 Driver installation 3 1 Windows Server OS Driver Installation ...

Page 4: ...etXtreme Ethernet Boot Agent Chapter 3 Driver installation This chapter provides instructions for installing the Ethernet card drivers on different operating systems Where to find more information Refer to the following sources for additional information and for product and software updates 1 ASUS websites The ASUS website provides updated information on ASUS hardware and software products Refer t...

Page 5: ...that you must type the command exactly as shown then supply the required item or value enclosed in brackets Example At the DOS prompt type the command line format a DANGER WARNING Information to prevent injury to yourself when trying to complete a task CAUTION Information to prevent damage to the components when trying to complete a task NOTE Tips and additional information to help you complete a ...

Page 6: ... s Ethernet 10GBASE T Dual Port Ethernet Controller PHY BCM 57840S BCM 84833 Connector RJ45 Copper Host Interface PCI E Gen3 x8 Form factor 4 72 in x 1 77 in lower than standard low profile Support Cable Type Category 6 Max length 55 meters Category 6a Max length 100 meters Category 7 Max length 100 meters Features PXE boot iSCSI boot ...

Page 7: ...1 Product introduction This chapter discuss the PEB 10G 57840 2T Ethernet card features and the new technologies it supports Chapter 1 Product introduction ...

Page 8: ... requires 3 CFM or above Server or workstation motherboard with a PCI Express x8 or x16 card slot Supported operating system Windows and Linux operating systems refer to the specification table or the ASUS website for the latest updates Standard Gift Box Pack Standard Bulk Pack Support DVD 1 1 per carton Low profile Bracket 1 1 Small Bracket for Node 1 1 Screws 4 4 Packing Quantity 1 pc per carton...

Page 9: ...45 Copper Port 2 3 PCI Express Gen3 x8 Interface 4 LAN2 LED 5 LAN1 LED 6 PCIE Link LED hidden LED indications Speed Link Status Description LAN1 LED LAN2 LED Green 10 Gbps link Amber 1 Gbps link Blinking Data Activity PCIE Link LED Green PCIE link Top view Bottom view ...

Page 10: ... bracket 1 Get the PEB 10G 57840 2T Ethernet card and place it on a stable and flat surface Ensure that the printed circuit board PCB is facing down 2 Remove the two screws that secures the PEB 10G 57840 2T Ethernet card to the card bracket A then remove the card bracket B 3 Get the replacement card bracket 4 Align and insert the PEB 10G 57840 2T Ethernet card into the mounting hole of the card br...

Page 11: ...2 Boot Agent Configuration This chapter provides instructions on setting the Broadcom NetXtreme Ethernet Boot Agent Chapter 2 Boot Agent Configuration ...

Page 12: ...Configure Enter Enter Next Menu Next Entry ESC Quit Menu 4 From the Main Menu use the up down arrow key to select an item and press Enter Comprehensive Configuration Management v7 10 31 Copyright C 2000 2014 Broadcom Corporation All rights reserved Device Hardware Configuration MBA Configuration iSCSI Boot Configuration NIC Partition Configuration Main Menu Configure Device Hardware Parameters Ent...

Page 13: ...ctors 0 Device Hardware Configuration Configure NIC Hardware Mode Enter Space Toggle Value Next Entry ESC Quit Current Adapter Primary Bus 03 Device 00 Func 00 MAC C8 60 00 22 86 B7 Multi Function Mode SF Configuration options SF NPAR DCB Protocol Disabled Configuration options Disabled Enabled Energy Efficient Ethernet Disabled Configuration options Disabled Optimal Power and Performance Maximum ...

Page 14: ...bled Configuration options Enabled Disabled VLAN Mode Disabled Configuration options Disabled Enabled VLAN ID 1 Configuration options 0 4094 Boot Retry Count 0 Configuration options 0 7 2 1 2 MBA Configuration Menu Comprehensive Configuration Management v7 10 31 Copyright C 2000 2014 Broadcom Corporation All rights reserved Option ROM Enabled Boot Protocol Preboot Execution Environment PXE Boot St...

Page 15: ...tatic IP address which is entered through the iSCSI Initiator Parameters Configuration screen CHAP Authentication Disabled Enabled Allows the iSCSI boot host software to use CHAP authentication when connecting to the iSCSI target Enter the CHAP ID and CHAP Secret in the Initiator Parameters configuration screen Disabled Does not allow the iSCSI boot host software to use CHAP authentication when co...

Page 16: ...seconds the iSCSI boot host software waits after an Ethernet link is established before sending any data over the network The valid values are 0 to 255 Use TCP Timestamp Disabled Enables or disables the TCP Timestamp option Configuration options Disabled Enabled Target as First HDD Disabled When enabled the iSCSI target drive appears as the first hard drive in the system Configuration options Disa...

Page 17: ...IP Address 192 168 110 1 ICP Port 3260 Boot LUN 0 iSCSI Name iqn iscsi4qtc1 CHAP ID CHAP Secret 1st Target Parameters Enable Disable Target Establishment Enter Space Toggle Value Next Entry ESC Quit Current Adapter Primary Bus 03 Device 00 Func 00 MAC C8 60 00 22 86 B7 Initiator Parameters Key in the necessary parameters The iSCSI Name varies depending on the iSCSI target in use Secondary Device P...

Page 18: ...ault NIC Partition Configuration Configure Physical Port Flow Control Enter Space Scroll Value Next Entry ESC Quit Current Adapter Primary Bus 03 Device 00 Func 00 MAC C8 60 00 22 86 B7 Flow Control Tx Rx Flow Control Configuration options Tx Rx Flow Control Disabled Auto Tx Send Pause on Rx Overflow Rx Throttle Tx on Pause Received PF 0 2 4 6 Press an item to configure its NIC Partition parameter...

Page 19: ...3 Driver installation This chapter provides instructions for installing the Ethernet card drivers on different operating systems Chapter 3 Driver installation ...

Page 20: ... displays the Drivers menu if Autorun is enabled in your computer If Windows automatically detects the LAN controllers and displays a New Hardware Found window click Cancel to close this window If Autorun is NOT enabled in your computer browse the contents of the Support CD to locate the file Setup exe Double click Setup exe to run the CD 3 Click Broadcom NetXreme II GigE Driver 4 Click Next when ...

Page 21: ...e terms in the license agreement and click Next to continue 6 Follow the screen instructions to complete the installation 7 If the Windows Security window appears during the driver installation click Install this driver software anyway to continue ...

Page 22: ...3 4 Chapter 3 Driver installation 8 Click Finish to exit the installation wizard 9 Restart the system ...

Page 23: ...rsion src rpm 3 2 Linux OS Driver Installation To install the Ethernet card driver for Linux OS 2 CD to the RPM path and build the binary driver for your kernel cd usr src redhat OpenLinux turbo packages rpm For RHEL 6 0 and above cd rpmbuild For Red Hat Linux For SuSE Linux For Red Hat Linux For SuSE Linux ...

Page 24: ...ll be compiled for the running kernel by default To build the driver for a kernel different than the running one specify the kernel by defining it in KVER rpmbuild bb SPECS netxtreme2 spec define KVER kernel version kernel version in the form of 2 x y z is the version of another kernel that is installed on the system 3 Install the newly built package driver and main page For Red Hat Linux For SuSE...

Page 25: ...ASUS PEB 10G 57840 2T 3 7 rpm ivh RPMS arch netxtreme2 version arch rpm where arch is the machine architecture such as i386 For Red Hat Linux ...

Page 26: ...3 8 Chapter 3 Driver installation For SuSE Linux ...

Page 27: ...rnels lib modules kernel_version kernel drivers net bnx2 ko lib modules kernel_version kernel drivers net bnx2x ko 2 6 16 and newer kernels lib modules kernel_version kernel drivers net bnx2 ko lib modules kernel_version kernel drivers net bnx2x ko lib modules kernel_version kernel drivers net cnic ko Newer RHEL and SLES distros lib modules kernel_version updates bnx2 ko lib modules kernel_version...

Page 28: ... bnx2 driver for the BCM5706 BCM5708 5709 5716 devices insmod bnx2 o or insmod bnx2 ko on 2 6 x kernels or modprobe bnx2 To load the bnx2x driver for the BCM57710 BCM57711 BCM57711E BCM57712 devices insmod bnx2x o or insmod bnx2x ko on 2 6 x kernels or modprobe bnx2x To load the cnic driver insmod cnic ko or modprobe cnic To load the bnx2i driver insmod bnx2i ko or modprobe bnx2i To load the bnx2f...

Page 29: ...her of these two options a Reboot the server b If already loaded unload inbox bnx2 bnx2x cnic drivers and load the newly installed version from netxtreme2 foce package using modprobe DRV NAME Driver upgrade rpm Uvh is not supported On SLES 11 change allow_unsupported_modules parameter value of etc modprobe d unsupport modules from 0 to 1 until bnx2fc driver is inbox Failing to do so will not load ...

Page 30: ...3 12 Chapter 3 Driver installation ...

Page 31: ...dress 15 Li Te Road Peitou Taipei Taiwan 11259 Telephone 886 2 2894 3447 Fax 886 2 2890 7798 E mail info asus com tw Web site http www asus com tw Technical Support Telephone 886 2 2894 3447 0800 093 456 Online Support http support asus com techserv techserv aspx ASUSTeK COMPUTER INC China Address No 508 Chundong Road Xinzhuang Industrial Zone Minhang District Shanghai China Telephone 86 21 5442 1...

Page 32: ...2010 09 EN 302 326 2 V1 2 2 2007 06 EN 302 326 3 V1 3 1 2007 09 EN 301 357 2 V1 4 1 2008 11 EN 302 291 1 V1 1 1 2005 07 EN 302 291 2 V1 1 1 2005 07 2006 95 EC LVD Directive EN 60950 1 A12 2011 EN 60065 2002 A12 2011 2009 125 EC ErP Directive Regulation EC No 1275 2008 Regulation EC No 642 2009 Regulation EC No 278 2009 Regulation EC No 617 2013 2011 65 EU RoHS Directive Ver 140331 CE marking Decla...

Reviews: