background image

1

ACER AB
Box 261
SE-433 25  PARTILLE
Sweden
T46 (0)31-446500
T46 (0)31-444410
www.acer.se

Instruction Manual

  CAT III 600V

Digital Multimeter

PASAR® 223

Copyright 

©

 2005 Acer AB. All rights reserved

Summary of Contents for PASAR 223

Page 1: ...ACER AB Box 261 SE 433 25 PARTILLE Sweden Telefon 46 0 31 446500 Telefax 46 0 31 444410 www acer se Instruction Manual CAT III 600V Digital Multimeter PASAR 223 Copyright 2005 Acer AB All rights reserved ...

Page 2: ...ent AC DC 18 4 3 Current Measurment up to 200mA 18 4 4 Resistance Measurement 19 4 5 Diode Test 19 4 6 Battery Test for 9V and 1 5V Batteries 19 5 0 Maintenance 5 1 Battery Replacement 20 5 2 Fuse Replacement 21 5 3 Cleaning 21 6 0 Technical Data 6 1 General 22 6 2 DC Voltage 22 6 3 AC Voltage 40 Hz 1 kHz 22 6 4 DC Current 22 6 5 Resistance 23 6 6 Diode Test 23 6 7 Battery Test 23 ...

Page 3: ... EEC Standards EN 50081 1 and EN 50082 1 are fulfilled It also complies with the Low Voltage Directive 73 23 EEC Standard EN 61010 1 is fulfilled After unpacking verify that the instrument is undamaged The scope of supply comprises 1 PASAR 223 2 test leads 1 battery 9V IEC 6F22 or 6LR61 1 Instruction manual 2 0 Safety Measures PASAR 223 has been constructed and verified in compliance with the safe...

Page 4: ... instrument are in perfect condition The instrument may only be used under the conditions and for the purposes for which it was constructed For this reason in particular the safety references the technical data including environmental conditions and the usage in dry environments must be followed The opening of the instrument may only be carried out by professionals except for fuse or battery repla...

Page 5: ...Connections 1 Digital Display 2 Symbol for negativ Voltage 3 Low battery indication 4 Measurement range selection switch 5 Input socket for voltage resistance and diode 6 Input socket COM 7 Input socket for Battery test and Current ...

Page 6: ... DC Do not connect the probes to more than 600V AC DC Exceeding these values can endanger the operator and may result in damage to the instrument 1 Select measurement range V V via measurement functionselection switch 4 If the value to be measured is un known the highest measurement range has to be selected 2 Connect the black test lead to the COM socket and the red test lead to the VΩ socket 3 Co...

Page 7: ...ed is not live 1 Select measurement range via measurement function selection switch 4 2 Connect the black test lead to the COM socket and the red test lead to the VΩ socket 3 Connect test leads to UUT 4 Read the voltage drop in the forward direction from the digital display In the reverese direction 1 should appear at the left side of the display Remark The polarity of the test voltage is at the r...

Page 8: ...he instrument from any circuit 2 Switch off instrument 3 Loosen the four screws on the instrument rear Lift the case cover 4 Remove the discharged batteriy 5 Insert a new battery Type IEC 6LR61 or 6F22 respect polarity 6 Replace the case cover and retighten the screws Now the measurings can be carried out as normal Please help care for our environment do not throw the used battery in the normal ho...

Page 9: ...itch off instrument 3 Loosen the four screws on the instrument rear Lift the case cover 4 Remove the defect fuse and insert new fuse type 200 mA fast acting 250V 5 x 20 mm Using auxiliary fuses in particular short circuiting fuse holders is prohibited and can cause instrument destruction or serious bodily injury of operator 5 3 Cleaning If the instrument is dirty after daily useage it is adviseabl...

Page 10: ... 6F22 or 6LR61 Fuse 200mA 250V fast acting 5 x 20 mm Dimensions 170 x 85 x 50 mm Weight approx 410 g 6 1 General 6 2 DC Voltage Range Resolution Accuracy Overload protection 2V 1mV 20V 10mV 1 2 3 digits 600V AC DC 200V 100mV 600V 1V Input inpedance 1M Ω 6 4 DC Current Range Resolution Accuracy Overload protection 200mA 100µA 2 5 3 digits 250V AC DC Burden voltage approx 5mV mA 6 3 AC Voltage 40 Hz...

Page 11: ...warranty valid only with invoice We will repair free of charge any defects in workmanship or material provided the instrument is returned unopened and untampered with i e with undamaged warranty label Any damage due to dropping or incorrect handling are not covered by the warranty 6 5 Resistance Range Resolution Accuracy Overload protection 2000 Ω 1Ω 20 kΩ 10 Ω 1 5 3 digits 600V AC DC 200 kΩ 100 Ω...

Page 12: ...12 ACERAB Box 261 SE 433 25 PARTILLE Sweden Location Brodalsvägen 7 Telefon 46 0 31 44 65 00 Telefax 46 0 31 44 44 10 www acer se ...

Reviews: