background image

 

 

AN1600 F1 Network Storage System Quick Specification 

 

 Product Overview 

Acer  AN1600  F1  storage  system  is  a  cost-effective  storage  solution,  powered  by  Microsoft  Windows  Storage 
Server offering an easy way for storage centralization, file sharing, data protection, and remote access.  

Processors and chipset 

2 x Intel

®

 Xeon

®

 E5620 processors (2.4 GHz, 12 MB L3 cache, 5.86 GT/s, DDR3-1066, 80 W, HT) 

Intel

®

 5520 Chipset 

Memory 

Type 

DDR3-1333 Registered (RDIMM) with ECC capabilities

 

Maximum memory by O/S

 

32 GB 

# of DIMM sockets

 

12 

Minimum (standard) memory on 
system

 

6 GB (2 GB x 3) 

Network controller 

Integrated Intel

®

 82576EB dual-port Gigabit Ethernet controller 

Storage

1

 

Maximum capacity 

1) 

Up to 12 x 3.5" Hot pluggable SAS/SATA HDD capacity

 

 

2) 

Up to 24 TB raw internal SATA 

3) 

Up to 7.2 TB raw internal SAS 

Minimum capacity 
External storage 

600 GB (300 GB x 2) internal SAS HDD 
Optional

2

 

Storage controller

3

 

LSI SAS MegaRAID SAS PCIe 2.0 x16 9260-16i with 16-internal ports, 512 MB, supporting RAID 0/1/10/5/50/6/60 
(default bundle in system) 

Expansion slots 

Seven PCI-Express slots 

 

Two PCI-Express Gen 2.0 x8 slots (in x4 connector; left)

 

 

One PCI-Express Gen 2.0 x16 slot (in x8 connector left)

 

 

Three PCI-Express Gen 2.0 x8 slots (in x4 connector; right*)

 

 

One Acer Flex I/O (PCIe Generation 2.0 x8 connector (left)

 

*Right hand side PCI-Express space has limitation for low-profile card, length within 5.6” 

Operating System 

 

Microsoft

®

 Windows

®

 Storage Server 2008 R2, Standard x64 edition

 

Management 

  Acer Smart Console 

  Acer Smart Server Manager 

  iBMC management controller, supporting base board management and KVM-over-IP 

  LSI MSM (MegaRAID Storage Manager) on-line utility is the OS level utility for data volume RAID configuration 

  LSI WebConsole utility is a ROM-based utility provided by HBA FW for data volume RAID configuration 

  Windows Disk Management is OS built-in feature on Windows Storage Server 2008 R2 

  Microsoft Windows Storage Server Administration Tools 

Deployment/serviceability 

   BIOS Update Tool 

  IPMI Firmware Update Tool 

Input/output interface 

Front 

  Power button 

  HDD activity indicator LED 

  PSU failure LED 

  Power indicator LED 

  Two LAN activity LEDs (LAN1, LAN2) 

  System status/fault indicator LED 

                                                

 
1. Storage capacity  

2

 External storage is available through fiber channel connection for additional storage devices 

3. 16 ports RAID card is now available starting from January, 2011 
 

Summary of Contents for AN1600 F1

Page 1: ...ss Gen 2 0 x8 slots in x4 connector left One PCI Express Gen 2 0 x16 slot in x8 connector left Three PCI Express Gen 2 0 x8 slots in x4 connector right One Acer Flex I O PCIe Generation 2 0 x8 connector left Right hand side PCI Express space has limitation for low profile card length within 5 6 Operating System Microsoft Windows Storage Server 2008 R2 Standard x64 edition Management Acer Smart Con...

Page 2: ...port RJ 45 dedicate management NIC Chassis form factor 2U rack optimized up to 12 hot pluggable 3 5 SAS SATA HDDs Power supply 2 x 720 W 80 PLUS Gold level efficiency power supply redundant hot plug Regulatory compliance standards EMC CE Class A Safety CB GS Dimensions 438 4 w x 705 D x 88 1 H mm 17 26 x 27 76 x 3 47 inches Form factor 2U rack optimized Product Overview ...

Page 3: ...sion 3 Intel Xeon processor 5600 series 4 12 DDR3 dual channel DIMMs 6 per CPU ECC support 4 5 2 x 720W 80 PLUS Gold level efficient PSU 1 1 redundant hot pluggable 6 3 1 redundant system fans 7 SAS SATA backplane 8 Front status indicators and power button 9 12 hot pluggable 3 5 SAS SATA HDDs 4 Maximum memory capacity is 32 GB per system by Operating System ...

Page 4: ...ation keeper in network with Microsoft based storage operating system to manage protect and expand Efficient operations Works together with Acer Smart Setup and Acer Smart Manager for faster installation and setup Microsoft Management Console user interface from Windows storage operating system enable you to use existing features such as iSCSI and SIS 5 allowing less maintenance and faster backup ...

Page 5: ... network environment Storage appliances running Windows Storage Server 2008 R2 can be used in failover clusters providing high availability storage for application servers and file storage Single Instance Storage SIS v2 SIS reduces the amount of storage used by data by replacing multiple identical copies with logical links to a single source copy File Server Optimization Windows Storage Server 200...

Page 6: ...m are collected into a single console As new applications are added to a computer or network their administration is integrated into the existing administration common console Customization of Consoles Administrators can create custom consoles tailored to their particular management needs This is useful in enterprise environments that divide administrator groups according to duties For example you...

Page 7: ...ket 2 System thermal solution is capable of supporting up to TDP 95W Intel Xeon 5600 EP processors include standard HE Cache Memory 12MB Shared L3 cache Chipset North Bridge Intel 5520 Chipset South Bridge ICH10R Memory Type DDR3 1066 1333MHz Registered memory DIMM sockets Twelve DIMM slots Capacity Registered DIMM 2 GB 4 GB Maximum memory Registered memory 32 GB Minimum memory Registered meory 6 ...

Page 8: ... graphics controller iBMC Video memory 8MB Supported resolution 1440x900 32b 60Hz 8 5 aspect ratio 1280x1024 32b 60Hz 5 4 aspect ratio Storage Controllers Six on board 3Gb s SATA ports 7 pin with RAID 0 1 5 10 support Expansion slots Left side Riser 1 Flex I O 1 PCI E x16 connector w Gen2 x8 link 2 PCI E x8 connector w Gen2 x4 link Right side Riser 3 PCI E x8 connectors w Gen2 x4 link NOTE 1 The s...

Page 9: ...s Dual Gigabit NIC with Activity and Link indicators One RJ45 dedicate management NIC with Activity and Link indicators One Serial port DB 9 One SVGA Video port DB 15 System ID LED Button NOTE Parallel port is NOT supported Language Support English Yes German Yes French Yes Italian Yes Spanish Yes Chinese traditional Yes ...

Page 10: ...2 PSU failure LED System status fault indicator LED Rear I O bracket 2 x PS2 ports 2 x USB 2 0 ports 1 x Serial port 2 x RJ45 connectors Dual Gigabit NIC with Activity and Link indicators 1 x RJ45 dedicate management NIC with Activity and link indicators 1 x SVGA Video port DB 15 1 x ID LED button Storage On board SATA Controller Intel 82801JR ICH10R I O Controller Hard disk drive Form factor 3 5 ...

Page 11: ...Hard disk drive bays 3 5 hard disk drive Maximum 12 bays Hot plug Interface PS2 Keyboard 1 PS2 Mouse 1 Parallel N A Serial port 1 rear side 1 on board 9 pin connector USB 2 0 ports Front USB N A Rear USB 2 Internal USB One Type A USB connector Three 2x5 pin Intel FPIO USB pin headers total 5 ports Input Requirements per power supply Range line voltage 100 240 VAC Rated input current 9 A 4A Rated i...

Page 12: ...m 10 000 ft Non operating 40 to 70 C 40 to 158 F Relative humidity non condensing Operating 8 to 90 relative humidity Rh 28 C 82 4 F maximum wet bulb temperature non condensing Non operating 5 to 95 relative humidity Rh 38 7 C 101 7 F maximum wet bulb temperature non condensing Acoustic noise Listed are the declared A Weighted sound power levels LWAd and declared average bystander position A Weigh...

Page 13: ...ass A NOTE Product conformance to cited product specifications is based on sample type testing evaluation or assessment This product or family of products is eligible to bear the appropriate compliance logos and statements Regulatory Compliant Standard EMC6 CE Class A Safety6 CB and GS 6 Compliance availability varies by region and country ...

Page 14: ...etwork Storage System Quick Specification RAID Volume and Setup Layout Default 2 HDDs RAID Volume and system partition Default 8 HDDs RAID Volume and system partition Default 12 HDDs RAID Volume and system partition ...

Page 15: ...nto P1DIMM1A to P1DIMM3B slots when CPU is installed in CPU1 socket The P2DIMM1A to P2DIMM3B slots are enabled when a second CPU is installed on the CPU2 socket For the system to function DIMM modules must be installed following the slot sequence listed below DIMM module of the same type size and manufacturer must be installed in the same colored DIMM slots Independent mode Single processor config...

Page 16: ...B 1A 2B 2A 3B 3A 1B 1A 2B 2A 3B 3A 4GB 2GB 2GB 6GB 2GB 2GB 2GB 8GB 2GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 16GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 18GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 24GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 8GB 4GB 4GB 12GB 4GB 4GB 4GB 16GB 4GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 32GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB ...

Page 17: ...channel The failed channel is then isolated and the spare channel becomes active However any uncorrectable error that happens before the isolation will still cause the system to stop normal operation Channel 3 is the spare channel Therefore the effective size will be reduced by one third Follow the population rules described in the independent mode Sparing mode requires that all three channels use...

Page 18: ...GB 4GB 4GB 4GB 24GB 8GB 8GB 8GB Dual processor configuration Total Physical Memory P1DIMM P2DIMM 1B 1A 2B 2A 3B 3A 1B 1A 2B 2A 3B 3A 6GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 18GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 24GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 12GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 36GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB ...

Page 19: ...ckplane works to apply system based control for power and fan speed functions RAID setup is limited to a three drive scheme RAID cannot be spread across all twelve drives Hard Disk Drive Support Drive Quantity Supported Bay Supported Required Controller 3 5 SATA SAS hard drive Up to 12 0 11 1 16 port SAS RAID card NOTE Transfer rates of drives are dependent on the maximum transfer rate supported b...

Page 20: ...ted Input Wattage Rating Watts 846 0 836 4 790 4 774 0 822 8 805 0 789 6 Max Rated VA Volt Amp 837 54 828 03 774 59 758 52 806 34 788 9 773 81 Efficiency at Max Rated Output Wattage 88 12 89 49 90 95 90 74 91 51 91 92 92 27 Power Factor 0 99 0 99 0 98 0 98 0 98 0 98 0 98 Leakage Current mA 0 17 0 19 0 29 0 31 0 35 0 37 0 41 Max Inrush Current A peak 17 24 19 41 18 52 16 88 16 48 20 47 22 54 Max In...

Page 21: ...A SAS RAID Card LSI SAS MegaRAID MegaRAID SAS 9260 16i bulk LSI Castor 16 internal ports 2108 IC 512MB PCI E 2 0 x 8 RAID 0 1 10 5 50 6 60 FC HBA Qlogic SANblade QLE2460 Single Port 4 Gbps Fibre Channel to PCI Express Host Bus Adapter 1ch 4Gb FC HBA PCI E x4 Single LC port w both std low profile bracket FC HBA Qlogic SANblade QLE2462 Dual Port 4 Gbps Fibre Channel to PCI Express Host Bus Adapter 2...

Page 22: ... MB supporting RAID 0 1 10 5 50 6 60 default bundle in system configuration 6 Removed 1 GB memory support 2011 01 06 2 0 1 1 Added additional 3 skus 2011 11 04 2 0 1 1 New Logo 2 Power Specifications duplicate removed In a continuing effort to improve the quality of our products information in this document is subject to change without notice Images shown are only representations of some of the co...

Reviews: