Page 1: ...2TMD041600D0130 04 11 2020 Product manual ABB Welcome M22341 _M22343 Basic 4 3 video hands free indoor station ...

Page 2: ... height 12 7 3 2 Dismantling 12 7 3 3 Surface mounted installation 13 7 3 4 Desktop installation 14 8 Commissioning 15 8 1 Common operation 15 8 2 Intercom settings 16 8 3 Switch actuator settings 17 8 4 Program button settings 18 8 5 Auto unlock settings 19 8 6 Unlock password settings 20 8 7 Ringtone settings 21 8 8 Volume settings 22 8 9 Date and time settings 23 8 10 Other settings 24 8 11 His...

Page 3: ...Inhaltsverzeichnis Product manual 2TMD041600D0130 3 10 Notice 41 ...

Page 4: ...th live components This can result in electric shock burns or even death Disconnect the mains power supply prior to installation and or disassembly Permit work on the 100 240 V supply system to be performed only by specialist staff 3 Intended use This device is an integral part of the ABB Welcome door communication system and operates exclusively with components from this system The device must on...

Page 5: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Page 6: ...me Hold this button more than 10 seconds to enable disable the Auto unlock function If the function is enabled the lock will be released automatically after the indoor station rings 5 seconds and this function will be available for 10 hours from the moment the function is enabled The backlit LED of this button lights on to indicate the Auto unlock function is enabled The backlit LED of this button...

Page 7: ... lock by default In standby status hold this button for 3 seconds to send an SOS alarm to the guard unit The backlit LED of this button flashes white slowly to indicate success This programmable button can be set to other function e g call guard unit intercom 7 Setting button In standby status press this button to enter the system setting screen The backlit LED of this button flashes fast to indic...

Page 8: ... the address hundreds digits of the indoor station 3 Master slave function Only one indoor station in an apartment can be set to Master ON Master All other indoor stations in the same apartment must be set to Slave OFF slave 4 Terminal resistor In video installations or mixed audio and video installations the switch must be set as ON at the last device of the bus line 5 a b BUS connection doorbell...

Page 9: ...gnation Value Display resolution 480 x 272 Display size 4 3 Operating temperature 10 C 55 C Storage temperature 40 C 70 C Protection IP 30 Single wire clamps 2 x 0 28 mm 2 x 0 75 mm Fine wire clamps 2 x 0 28 mm 2 x 0 75 mm Bus voltage 20 30 V Size 154 mm x 134 mm x 23 mm ...

Page 10: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Page 11: ...ormer and other power supplies to avoid interference Do not install the wires of the system bus together with 100 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a four core or multi core cable When looping never install the incoming and outgoing bus in...

Page 12: ...Mounting Installation Product manual 2TMD041600D0130 12 7 3 Mounting 7 3 1 Installation height 7 3 2 Dismantling 1 50 m 4 9 feet ...

Page 13: ...Mounting Installation Product manual 2TMD041600D0130 13 7 3 3 Surface mounted installation Surface mounted box unit mm Installation 1 Mounted on the wall 95 60 116 83 83 7 9 ...

Page 14: ...Mounting Installation Product manual 2TMD041600D0130 14 2 Mounted with flush mounted box 7 3 4 Desktop installation ...

Page 15: ... quickly 2 In normal status press this button to select the next item In setting status press this button to change the setting or scroll up the letter number hold the button to scroll up the letter number quickly 3 In normal status press this button to enter the setting In setting status press this button to confirm the setting 4 In normal status press this button to turn back to the previous scr...

Page 16: ...ting status press or button to set the call type between External Intercom and Internal Intercom 4 When the call type is set to External Intercom in setting status press or button to set the address of target indoor station 001 250 5 In setting status press or button to set a new name 6 In normal status press button to save the settings Intercom1 Intercom2 Add New 001 1 2 1 CallType Target Address...

Page 17: ... new switch actuator maximum 10 3 Target address In setting status press or button to set the address of target switch actuator 001 199 4 In setting status press or button to set a new name 5 In normal status press button to save the settings SWITCH ACTUATOR Actuator1 AddNew 001 2 1 1 SWITCH ACTUATOR Target Address Rename 002 light Save Cancel 4 3 5 1 ...

Page 18: ...settings No Description 1 Program button function In setting status press or button to set the function for the program button e g releasing second lock calling guard unit intercom call releasing the existing switch actuator PROGRAM BUTTON Button1 Release 2nd lock 1 1 ...

Page 19: ...setting status press or button to set start time and end time 4 Time 2 function In setting status press or button to enable disable the function 5 Time 2 settings In setting status press or button to set start time and end time Note If the Auto unlock function is enabled the Call forward function will be disabled automatically This function can only be set on the master indoor station AUTO UNLOCK ...

Page 20: ...tion 1 In setting status press or button to enable disable the function 2 Unlock password In setting status press or button to set the password 3 8 digits Note This function can only be set on the master indoor station SETOSPASSWORD Enable Password Enter Password 3 8digits 12345678 1 1 2 ...

Page 21: ... In setting status press or button to select a ring tone for other outdoor stations 3 In setting status press or button to select a ring tone for doorbell 4 In setting status press or button to select a ring tone for other devices e g guard units and indoor stations RING TONE Default Outdoor RingTone1 Other Outdoors RingTone2 Doorbell RingTone3 Others RingTone4 1 3 2 1 4 ...

Page 22: ...o Description 1 In setting status press or button to set the volume 2 In setting status press or button to enable disable the function 3 In setting status press or button to enable disable the function VOLUME Ringtone Volume Volume3 Touchbutton Tone Repeated Tone 1 3 2 1 ...

Page 23: ... settings No Description 1 In setting status press or button to set the date 2 In setting status press or button to set the time 3 In setting status press or button to enable disable the function DATE AND TIME Date YYYY MM DD Time Summer Time 2013 01 01 08 00 3 2 1 1 ...

Page 24: ...to enable disable the function a sensor should be connected to the outdoor station before use 3 In setting status press or button to enable disable the function 4 In setting status press or button to enable disable the function button flashes white when there are missed calls and this function is enabled OTHER SETTINGS Auto Full Screen Door Status Check Auto snapshots Missed 1 3 2 1 4 ...

Page 25: ...pported will be displayed if the Auto snapshots function is enabled means dialing a call means receiving a call means a missed call 2 Press this button to view the details of the record 3 Press this button to delete this record HISTORY Outdoor 1 2013 03 21 16 45 1 63 Outdoor 1 Outdoor 1 2013 03 21 16 43 2013 03 21 14 24 1 2 3 1 Outdoor 1 1 2 1 ...

Page 26: ...iew some images from them you need to enable the Camera list function to edit your camera list Enable the Camera list function Please follow the steps below 1 Press button to access the operation screen 2 Press or to select on the left list 3 Press to enable the function Enable the cameras displayed on the screen indicates the function is enabled CAMERA LIST Enablethecameras Outdoor1 1 Outdoor1 2 ...

Page 27: ...llow the steps below 1 In standby status press button to access the communication screen 2 Press or to select on the left list and then press to access the camera list 3 Press or to select the designated camera and then press twice to remove the camera CAMERA LIST Enablethecameras Outdoor1 1 Outdoor1 2 Camera1 ON 1 1 1 ...

Page 28: ... the left list and then press to access the camera list 3 Press or to select the designated camera and then press to access the detailed settings 4 Press or button to hide unhide the camera from the camera list 5 Press to select Save and then press to save the settings CAMERA LIST Enablethecameras Outdoor1 1 Outdoor1 2 Camera1 ON 1 1 1 CAMERA LIST Camera1 Enable Rename Visual Doorbell Front door S...

Page 29: ...left list and then press to access the camera list 3 Press or to select the designated camera and then press to access the detailed settings 4 Press to select Rename and then press or button to rename the camera 5 Press to select Save and then press to save the settings CAMERA LIST Enablethecameras Outdoor1 1 Outdoor1 2 Camera1 ON 1 1 1 CAMERA LIST Camera1 Enable Rename Visual Doorbell Front door ...

Page 30: ...era interface Camera interface works at mode 4 and is related to the indoor station Please see the product manual of camera interface for more details Enable the Visual doorbell function Please follow the steps below 1 In standby status press button to access the operation screen 2 Press or to select on the left list and then press to access the camera list 3 Press or to select the designated came...

Page 31: ...MD041600D0130 31 4 Press to select Visual Doorbell and then press or button to enable the function 5 Press to select Save and then press to save the settings CAMERA LIST Camera1 Enable Rename Visual Doorbell Front door Save Cancel 1 ...

Page 32: ...en 2 Press or to select on the left list 3 Press to disable the function Disable the cameras will be displayed on the screen 4 Repeatedly press button to view all the images from the outdoor station and the cameras 5 Then when you turn back to camera list all the lost cameras are displayed on the screen again CAMERA LIST Disablethecameras Outdoor1 1 Outdoor1 2 Camera1 OFF 1 1 1 ...

Page 33: ...Commissioning Product manual 2TMD041600D0130 33 8 13 Language LANGUAGE English Française Italiano Español Português 1 ...

Page 34: ...TMD041600D0130 34 8 14 Information You can use your mobile to scan QR code to obtain the product manual on the website INFORMATION Flash Version MCU Version M S Indoor St Add Default Outdoor V2 07_150629 V2 07_150723 Master 001 1 1 ...

Page 35: ...ll settings Reset all settings to factory default But data like history records existing intercoms and existing switch actuators will not be reset 2 Clear all data Reset all the settings and data to factory default RESET FACTORY DEFAULT Are you sure to reset Reset All Settings Cancel OK Clear All Data 1 2 1 ...

Page 36: ...o initiate a surveillance Hold this button to take a snapshot during the surveillance 4 Press this button to mute the ringtone of an incoming call Press this button to mute the microphone during the conversation 5 Press this button to carry out the function assigned to the program button 6 Press this button to enable or disable the full screen function Hold this button to access the brightness and...

Page 37: ...r 3 seconds to enter the display settings No Description 1 In setting status press or button to adjust the volume 2 Display the value of volume saturation brightness 3 In setting status press or button to adjust the saturation 4 In setting status press or button to adjust the brightness 1 Outdoor1 120s 1 2 3 4 ...

Page 38: ...steps below 1 In standby status press button to access the operation screen 2 Press or to select on the left list 3 Press to access the corresponding screen 4 Press or to select the designated intercom then press to initiate an intercom call Intercom1 Intercom2 001 1 INTERCOM ...

Page 39: ...all guard unit Please follow the steps below 1 In standby status press button to access the operation screen 2 Press or to select on the left list 3 Press to access the corresponding screen 4 Press to call guard unit Call Guard Unit 1 CALL GUARD UNIT ...

Page 40: ... steps below 1 In standby status press button to access the operation screen 2 Press or to select on the left list 3 Press to access the corresponding screen 4 Press or to select the designated switch actuator 5 Press to release the designated switch actuator 1 SWITCH ACTUATOR Actuator1 001 ...

Page 41: ...ed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Page 42: ... No 7 Fangshan South Road Hi tech area Torch park Xiang An District Xiamen China Tel 86 592 295 9000 Fax 86 592 562 5072 www abb com Copyright 2020 ABB All rights reserved Specifications subject to change without notice 2TMD041600D0130 ...