background image

1

WARNING: Because of the possible danger to person(s) or 

property from accidents which may result from the improper 

use of products, it is important that correct procedures be 

followed. Products must be used in accordance with the 

engineering information specified in the catalog. Proper 

installation, maintenance and operation procedures must 

be observed. The instructions in the instruction manuals 

must be followed. Inspections should be made as necessary 

to assure safe operation under prevailing conditions. Proper 

guards and other suitable safety devices or procedures as 

may be desirable or as may be specified in safety codes 

should be provided, and are neither provided by ABB nor 

are the responsibility of ABB. This unit and its associated 

equipment must be installed, adjusted and maintained by 

qualified personnel who are familiar with the construction 

and operation of all equipment in the system and the 

potential hazards involved. When risk to persons or property 

may be involved, a holding device must be an integral part 

of the driven equipment beyond the speed reducer output 

shaft.

WARNING: To ensure the drive is not unexpectedly 

started, turn off and lock-out or tag power source before 

proceeding. Failure to observe these precautions could 

result in bodily injury. 

WARNING: All products over 25 kg (55 lbs) are noted on the 

shipping package. Proper lifting practices are required for 

these products.

Dodge

®

 Sleevoil

®

 Heater-Thermostat Assembly

These instructions must be read thoroughly before installation or operation. This instruction manual was accurate at the time of 
printing. Please see 

baldor.com

 

for updated instruction manuals.

Note! The manufacturer of these products, Baldor Electric Company, became ABB Motors and Mechanical Inc. on 

March 1, 2018. Nameplates, Declaration of Conformity and other collateral material may contain the company name of 

Baldor Electric Company and the brand names of Baldor-Dodge and Baldor-Reliance until such time as all materials have 

been updated to reflect our new corporate identity.

The Dodge heater and thermostat is combined into one 
assembly. The thermostat is built into the first 2” from the tip of 
the heater. The thermostat is set to turn the heater on at 70°F 
(21°C) and  off at 100°F (38°C).  Also, an LED indicates when the 
heater is on.

Assembly components:

1.  Heater-Thermostat
2.  LED light
3.  Toroid (copper winding ring) 
4.  LB conduit enclosure 
5.  Brass Reducer*
6.  Aluminum reducer (for electrical outlet)
*Only used when the heater plug on the bearing is 1/2” or 3/4” 
NPT.

 Installation:

1.  Shut down the main fan by following the manufacturer’s 

instructions.

2.  To prevent oil from seeping out during installation, drain 

the oil from the bearing until the oil level is below the 
heater plug. The heater plug location is specified in the 
appropriate Sleevoil Instruction Manual.

NOTE: If the heater-thermostat is replacing an existing 

heater and thermostat, the old thermostat should be 

removed and replaced with a threaded plug.

3.  Remove the heater plug.
4.  Apply sealant to the pipe fitting (inner threads) on the 

heater-thermostat and install it in the bearing housing 
where the heater plug was removed. (On bearings where 
the heater plug is 1/2” or 3/4” NPT, use sealant to install the 
supplied brass reducer first.)

5.  The conduit body can be mounted vertically or horizontally. 

Determine which mounting configuration will be easiest to 
install. If space limitations prevent the LB enclosure from 
being installed, alternate conduit can be provided by a 
qualified electrician. Use sealant to install the conduit body 
on the outer threads of the heater thermostat. 

6.  Wrap one of the two red power leads around the toroid 

(copper winding ring) 1 or 2 times. See Figure 1.

7.  Connect the heater leads to a power supply and 

ground. The 2 red leads are 120 or 240 VAC power leads 
(depending on heater) and the green lead with the yellow 
tracer is the ground lead.

8.  The aluminum reducer is for the outlet of the conduit 

enclosure and can be installed if desired.

9.  Install the conduit body cover.
10.  Fill the bearing with oil to its recommended level.

LED Light

Toroid Ring

Ground
(Green)

Heater with Built-In 
Thermostat

Power

(Red)

Figure 1 - Heater / Thermostat Wiring

WARNING: Do not start the fan if the oil temperature is too 

low. This can result in an insufficient oil film in the bearing 

which may result in bearing failure. ABB recommends the 

oil temperature to be 70°F (21°C) or above.