Summary of Contents for BT030

Page 1: ...ABB SACE ABB SACE SD Pocket 1SDH000503R0002 L3104 EN SD Pocket User Manual ...

Page 2: ...2 2 UNINSTALLATION 6 3 PROGRAM START UP 7 4 LOG IN PROCEDURE 9 5 HOME PAGE 10 5 1 FUNCTIONS MENÙ 12 5 1 1 User management 12 5 1 2 Password management 15 5 1 3 Help 15 6 SELECT DEVICE 18 7 CONNECTION 20 7 1 DISCONNECTION 20 8 BROWSING THE DEVICE 21 8 1 ARCHITECTURE OF PAGES 21 8 2 WRITE ACCESS PASSWORD 23 9 SD DATA VIEWER 24 9 1 SOFTWARE REQUIREMENTS 24 9 2 INSTALLAZIONE 24 9 3 UNINSTALLATION 24 9...

Page 3: ...1 USER MANAGER PAGE 12 FIGURE 12 USER SETTINGS PAGE 13 FIGURE 13 ENABLE DEVICES PAGE 14 FIGURE 14 PASSWORD MANAGEMENT PAGE 15 FIGURE 15 HELP ICON 15 FIGURE 16 CURRENT USER WINDOW 16 FIGURE 17 HELP ON LINE PAGE 16 FIGURE 18 ABOUT SD POCKET WINDOW 17 FIGURE 19 CONNECTED DEVICE 17 FIGURE 20 DEVICE LIST PAGE 18 FIGURE 21 LIST OF FOUND DEVICES 18 FIGURE 22 DEVICE DESCRIPTION 20 FIGURE 23 ARCHITECTURE O...

Page 4: ...ABB SACE ABB SACE SD Pocket 1SDH000503R0002 L3104 3 25 Index of tables Pag TABLE 1 SUPPORTED DEVICES 4 TABLE 2 USER PROFILES 9 TABLE 3 ALARM TRIP SIGNALLING 21 TABLE 4 WRITE PASSWORD 23 ...

Page 5: ...ble 1 Supported devices without PR120 D BT 1 1 System requirements This software is available for installation on pocket PCs PDA Personal Digital Assistant 1 1 1 Hardware Integrated Bluetooth module with a minimum range of 10 meters see the PDA technical characteristics RAM 64 MB ROM 32 MB 30 MB free space PDA screen size 240 x 320 pixels 1 1 2 Software Windows Mobile 2003 or Windows Mobile 5 0 Ve...

Page 6: ...ust be connected to PDA through the serial USB port The installation file is executed on the PC having the requirements as per paragraph the user is asked to select the language of the application Figure 2 Language selection Once the procedure is ended the program is transferred to the PDA through serial USB connection Verify that the program has been properly installed on the PDA If replacement o...

Page 7: ...DH000503R0002 L3104 6 25 2 2 Uninstallation WARNING The PC must be connected to the PDA through the serial USB port In the PDA version the following window will appear Figure 3 PDA uninstallation Select ABB SD Pocket Click on Remove ...

Page 8: ...up From the Start menu of Windows Mobile 2003 select Programs Figure 4 Program start up Click the SD Pocket icon Figure 5 SD Pocket icon in the Program page The program starts up and the following splash screen will appear for few seconds necessary for the program loading ...

Page 9: ...ABB SACE ABB SACE SD Pocket 1SDH000503R0002 L3104 8 25 Figure 6 Splash screen After the program has been loaded the Log in page appears Figure 7 Log in page ...

Page 10: ...h the highest rights He can access all functionalities He can modify the rights of the users He can modify his password He cannot modify his user name User1 User2 User User3 0001 He can access all the functionalities permitted by the Administrator He can modify his user name and password His standard access is in read mode Table 2 User profiles A maximum number of three errors user name or passwor...

Page 11: ...he following actions available within the toolbar Figure 9 Functions menù Functions the user can select between the following actions for more details see paragraph 5 1 o Log out user disconnection and return to the log in page o User manager for Administrator only other users access rights modification o Password manager current user s password modification o Exit program shut down ...

Page 12: ...y connected o Help help page visualization o About SD Pocket visualization of the SW s version In this page it is possible to activate the device selection function which visualizes the devices within the range of action of the PDA with which it is possible to establish a connection By pressing the Select Device button the Bluetooth antenna is turned on until program exit ...

Page 13: ... and all the users have read only access rights The users can be enabled to the following functions Write Access modification of the parameters of connected device Commands commands to the connected device Test test operations to the connected device Disable device selection of the devices that can be accessed by the user From the toolbar the following actions can be selected Back the previous pag...

Page 14: ...d the input of the new password Selecting OK the new data are temporarily saved and the User management page is returned The data are permanently saved only after pressing the Save button in the User management page In the User settings page a window appears that explains this procedure By selecting Cancel the old data are reestablished and the User management page is returned From the toolbar the...

Page 15: ...is disabled Device List list of the devices available in the database In the devices list it is possible to select each device for which the user will be enabled From the toolbar it is possible to select the following actions Back the User management page is returned without saving any changes the user is warned the changes have not been saved and is given the chance to save them Cancel the change...

Page 16: ...rectly confirmed an error message appears Pressing OK the consistency checks are performed and if positive the new password is saved Selecting the Cancel the old password is reconfirmed From the toolbar the following actions can be selected Help 5 1 3 Help The Help menu is available throughout all the pages of the program and is identified by the following icon Figure 15 Help icon Selection of the...

Page 17: ...cted Figure 16 Current user window 5 1 3 2 On line help The following page is visualized Figure 17 Help on line page From the option tree in the upper side of the page the user can select the argument he is interested in that will appear in the lower portion of the page Selecting the Back button in the toolbar the help page is closed and the program is returned ...

Page 18: ...5 1 3 3 About SD Pocket A window appears in which the SW version of the program and its release date are given Figure 18 About SD Pocket window 5 1 3 4 Connected device When a connection is active the connected device is visualized Figure 19 Connected device ...

Page 19: ...ive during the search only At the end the information collected by the program is compared to those available in the device database Is the device is not present in the database this is updated within many seconds this operation is in administrator access only The list of ABB SACE SpA devices found by the program is visualized with indication of the type and tag name Only the ABB SACE SpA recogniz...

Page 20: ...the devices search procedure is restarted This button is activated once the previous search has ended Connect the connection to the selected device is starter This button is activated once a device has been selected From the toolbar the following actions can be selected Back the home page is returned Help ...

Page 21: ...arch starts Wink it activates the blinking of the display or of one LED of the device depending on the type of connected device The icon changes according to the wink condition Home page the homepage is returned Help In the page the Enter button can be selected to start surfing into the pages of the device for all the devices the Information Protection device is the initial page The following page...

Page 22: ...turned and the disconnection of the device occurs Wink it activates the blinking of the display or of one LED of the device depending on the type of connected device The icon changes according to the wink condition Help In the lower part of the page a message and LED are visualized in the following conditions Message LED Meaning OK Green No alarm is occurring Alarm Red Alarm occurring for details ...

Page 23: ...s visualized For example page 1 is selected page 1 1 is visualized The secondary pages can have lower level pages that can be selected by means of buttons In the following image it can be seen that selecting Measures the Currents page is visualized this page itself is organized in secondary pages one for each available measure on the connected device current voltages etc Figure 25 Measure page and...

Page 24: ...s required Figure 26 Write enable password In the following table the passwords to access the programming session of each device can be found Trip unit Write password PR121 P 0001 PR122 P Device password PR123 P Device password PR222DS P 0001 PR222DS PD 0001 PR223EF 0001 PR223DS 0001 PR232 P 0001 PR331 P 0001 PR332 P Device password PR333 P Device password Table 4 Write password ...

Page 25: ... is showed select SD DataViewer Figure 27 Selection of the program to be installed SD DataViewer To install SD DataViewer administrative rights are necessary Before the installation if a previous version of SD DataViewer is installed it is necessary to remove it see 9 3 9 3 Uninstallation Follow the path Start Settings Control Panel Add Remove Programs From the list select SD DataViewer and press ...