A B B ME A SUR EMENT & A N A LY TIC S | COMMUNIC ATIONS SUPPLEMENT

AWT210

HART 2-wire transmitter

Measurement made easy

Introduction

This Communication Supplement provides 
procedures specifically related to the AWT210 
HART® 2-wire transmitter. Refer to the AWT210 
Operating Instruction (

OI/AWT210-EN

) for general 

information on installation, operation and 
maintenance.

For more information

Further publications for the AWT210 transmitter are 
available for free download from: 

www.abb.com/measurement

 

or by scanning this code:

Search for or click on:

AWT210 transmitter –
Data Sheet

DS/AWT210-EN

AWT210 transmitter –  
Commissioning Instruction

CI/AWT210-EN

AWT210 transmitter –
Operating Instruction

OI/AWT210-EN

AWT210 transmitter –  
HART FDS Communications Supplement

COM/AWT210/ 

HART/FDS-EN


AWT210 
2-Wire transmitter

Summary of Contents for AWT210

Page 1: ...al information on installation operation and maintenance For more information Further publications for the AWT210 transmitter are available for free download from www abb com measurement or by scannin...

Page 2: ...Transmitter functionality and operator interface controls 6 Process interface 6 Sensor Input Channels 6 Host interface 6 Analog output 6 Local interfaces jumpers and switches 6 Local controls and dis...

Page 3: ...RNING BODILY INJURY Installation operation maintenance and servicing must be performed by suitably trained personnel only in accordance with the information provided in this manual in accordance with...

Page 4: ...or disposal at no charge to the user ABB is committed to ensuring that the risk of any environmental damage or pollution caused by any of its products is minimized as far as possible IMPORTANT NOTE Fo...

Page 5: ...re sensor ORP Oxidation reduction potential DDL Device description language HART Highway addressable remote transducer HHT Hand held terminal Reference documents Document ID Title DS AWT210 EN AWT210...

Page 6: ...tory settings If powered up with SW1 in the OFF position the device retains previously saved user settings SW2 Write Protection If SW2 is in the ON position HW write protect shows as enabled and the u...

Page 7: ...022 amps x R ohms Load resistance must include any meters external to the AWT210 transmitter the wiring and the system input IMPORTANT NOTE The equation for minimum supply voltage is based on a maximu...

Page 8: ...tters on the bus Each transmitter on the bus is wired from the primary communication device to the positive and negative POWER SIGNAL terminals of the AWT210 Connect all transmitters on the bus in par...

Page 9: ...by enabling PDM compatibility at the following menu Device Setup PDM Compatibility Enable Device specific HART commands general Command Description 122 Login to Service Level 123 Read Board Object 124...

Page 10: ...Parameters 164 Read Factory Calibration Slope and Offset 252 Read PV Sensor Config Table 4 Device specific HART commands Two Electrode conductivity TE Device specific HART commands Toroidal Conductiv...

Page 11: ...figuration 220 Read Temperature Sensor and Compensation Configuration 221 Write pH Solution Coefficient Value 222 Write millivolt Solution Coefficient Value 223 Read Primary Variable Transfer Function...

Page 12: ...to make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB AG does not accept any responsibility wh...