A B B ME A SUR EMENT & A N A LY TIC S | INSTRUC TION M A NUA L | IM/9 4 0 8 R E V. K

9408 series

Dissolved oxygen systems

Measurement made easy

Introduction

The 9408 Series dissolved oxygen system comprises 
a flat-ended sensor mounted into a relatively large 
diameter spherical flotation collar. This form of 
construction presents to the sample a surface on 
which it is difficult for rags and other large solids to 
lodge. For more demanding applications, on-line 
cleaning is available using the water wash option.

— 
9408 series 
Dissolved oxygen 
systems

Summary of Contents for 9408 700

Page 1: ...xygen system comprises a flat ended sensor mounted into a relatively large diameter spherical flotation collar This form of construction presents to the sample a surface on which it is difficult for rags and other large solids to lodge For more demanding applications on line cleaning is available using the water wash option 9408 series Dissolved oxygen systems ...

Page 2: ... more information Further publications are available for free download from www abb com analytical or by scanning this code Search for or click on 9408 series Dissolved oxygen systems Data Sheet DS 9408 EN ...

Page 3: ...npacking 2 2 2 Floating Ball System 2 2 2 1 Assembled Version 2 2 2 2 Kit Version 2 2 3 Dip Systems 3 2 3 1 Assembled Version 3 2 3 2 Kit Version 3 2 4 Submersible System 3 3 MECHANICAL INSTALLATION 4 3 1 Assembling Kit Systems 4 3 1 1 Floating Ball 4 3 1 2 Dip 5 3 2 Installation 6 3 2 1 Floating Ball System 6 3 2 2 Dip Systems 7 3 2 3 Submersible Systems 7 3 3 Water Supply for Water Wash Systems ...

Page 4: ...I T P O M E T S Y S d r a d n a t S r e t a w h t i W h s a W h s a W h s a W h s a W h s a W c i r t e M 0 5 7 8 0 4 9 2 5 7 8 0 4 9 l a i r e p m I 0 6 7 8 0 4 9 2 6 7 8 0 4 9 s n o i s n e m i D e p i P c i r t e M 0 1 N P t w 3 3 x m m 0 5 d o e p i p S B A l a i r e p m I E s s a l C t w 5 4 x B N 2 1 1 e p i p S B A 2 1 Unpacking After carefully removing the 9408 system from its packing chec...

Page 5: ...o scale Ø40 mm User supplied tube ABS or PVC 1 9 inches O D Contents 1 Top cap with fixing screw 2 Adaptor 3 Shroud 4 Sensor block with cable attached and dummy sensor fitted 5 Dissovled oxygen sensor capsule 6 Tangit Solvent Cement not provided Contents 1 Top cap with fixing screw 2 Adaptor 3 Shroud 4 Sensor block with cable and water wash tube attached and dummy sensor fitted 5 Dissovled oxygen ...

Page 6: ...4 4 5 4 3 1 Assembling Kit Systems 3 1 1 Floating Ball Fig 3 1 For installation of the assembled unit see Section 3 2 1 Floating Ball System Fig 3 1 Floating Ball Kit Assembly 3 MECHANICAL INSTALLATION ...

Page 7: ...5 3 MECHANICAL INSTALLATION 3 1 2 Dip Fig 3 2 For installation of the assembled unit see Section 3 2 2 Dip Systems Fig 3 2 Dip Kit Assembly ...

Page 8: ...nt cable slack for positioning servicing procedure Make the necessary electrical connections see Section 4 ELECTRICAL INSTALLATION If applicable arrange to have a water wash mains supply available see Section 3 3 and connect to the quick fit connector on the end cap 1 3 2 5 6 4 Standard Swivel Standard Swivel C Standard Swivel C 30 Viewed from above 3 2 Installation Caution The system is supplied ...

Page 9: ...rovided This is to prevent cable strain and allows the system to be lowered to the required depth 3 2 2 Dip Systems Fig 3 4 Note The standard dip system is supplied with the temperature probe and oxygen sensor body fitted Before fitting the dip tube to any bracket or fixing remove the protective shroud unscrew the dummy capsule from the end of the oxygen sensor body and fit the oxygen sensor capsu...

Page 10: ...cal water authority and council bylaws Caution The maximum water pressure at the electrode should not exceed 50psi 4 bar At NO time should the sample pressure be allowed to exceed that of the water wash water supply Fit a non return valve if this possibility exists Information As all quick fit connectors used in Water Wash systems incorporate cutoff valves tubes may subsequently be disconnected on...

Page 11: ...ively 4 2 Calibrating the Sensor Fig 4 1 The procedures for zero and span calibration are fully described in the 4600 Series Transmitter Unit Operating Instructions to which reference should be made Note It is advisable to switch off the water wash before starting the calibration procedure This can be done either by turning off at the 4600 transmitter unit or by disconnecting the quick fit connect...

Page 12: ... Section 4 2 Calibrating the Sensor Caution Do not leave the new capsule exposed to air for more than 30 minutes as the membrane will dry out Ensure the following steps are done carefully to avoid damaging the membrane covering the silver cathode Align the holes in the end of the ball with the protruding sensor capsule and temperature compensator and replace the ball assembly over the sensor pipe ...

Page 13: ...n box if applicable and attach a draw wire of suitable length 3 Slacken the cable gland on the end of the boom 4 Remove the self tap screw and pull off the end cap 5 Draw the cable through the gland 6 Unscrew the securing ring of the ball float whilst restraining the ball from turning and withdraw the ball from the elbow union 7 Carefully unscrew the sensor block from the end of the sensor pipe 8 ...

Page 14: ...ure Compensation Automatic correction by means of integral Pt100 resistance thermometer Accuracy 0 2mgl 1 or 2 saturation within 10 C of the calibration temperature in the range 0 to 35 C Operating Temperature Range 0 to 40 C Operating Pressure Atmospheric Dimensions Floating Ball Ball diameter 203 mm Boom outside diameter Metric 50 mm Imperial 17 8 in 48mm approximately Boom length Assembled 3 me...

Page 15: ...l System Table 7 1Floating Ball Spares List Fig 7 2Dip System Table 7 2Dip Spares List 7 SPARE PARTS LIST m e t I o N n o i t p i r c s e D o N t r a P 1 y l b m e s s A t a o l F l l a B 5 6 0 8 0 4 9 2 t e k c a r B d r a d n a t S y l b m e s s A c i r t e M 5 1 1 8 0 4 9 l a i r e p m I 6 1 1 8 0 4 9 A 2 t i K y l b m e s s A l e v i w S c i r t e M 5 3 1 8 0 4 9 l a i r e p m I 6 3 1 8 0 4 9 ...

Page 16: ...rsion Kit Fig A 1 Items in Conversion Kit Fig A 2 Assembled Kit APPENDIX A SUPPORT BRACKET CONVERSION m e t I o N o N o N o N o N n o i t p i r c s e D o N f f O f f O f f O f f O f f O s o N t P 1 s p m a l c m o o B 4 t i K c i r t e M 5 3 1 8 0 4 9 t i K l a i r e p m I 6 3 1 8 0 4 9 2 s d n e s p m a l c m o o B 2 3 s t l o b s p m a l c m o o B 4 4 w e r c s r e d l u o h S 1 5 e t a l p l e ...

Page 17: ...15 NOTES ...

Page 18: ...16 NOTES ...

Page 19: ...Sales Service ...

Page 20: ...ights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB ABB 2018 ABB Limited Measurement Analytics Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel 44 0 1453 826661 Fax 44 0 1453 829671 Email instrumentation gb abb co...