background image

VER:V1.2  

     

 28.04.2017

ABB-Welcome

Pos: 2 /DinA4  - Anl eitun gen  Online /Inh alt/KNX/Doo rEntry /832 20-AP- xxx/Tit elblat t -  832 20-AP-xxx  - ABB @ 1 9\m od_ 132 3249 806 476 _15. docx  @ 11 108 4 @   @ 1

83327-500

Camera interface

=== E nde der Liste für Tex tma rke C over == =

Summary of Contents for 83327-500

Page 1: ...B Welcome Pos 2 DinA4 Anl eitun gen Online Inh alt KNX Doo rEntry 832 20 AP xxx Tit elblat t 832 20 AP xxx ABB 1 9 m od_ 132 3249 806 476 _15 docx 11 108 4 1 83327 500 Camera interface E nde der Liste für Tex tma rke C over ...

Page 2: ...iated with outdoor station 7 4 2 3 Mode 3 works associated with guard unit 8 4 2 4 Mode 4 programming mode 9 4 3 Programming mode 10 4 4 With and without permanent power supply 11 4 5 Video signal from third party DVR 12 4 6 Video signal to be stored to third party DVR 13 5 Technical data 14 5 1 Overview table 14 5 2 Device connection diagram 14 6 Mounting Installation 15 6 1 Requirements for the ...

Page 3: ...aesse r Ge bra uch 83 220 AP xxx 500 2 0 mo d_1 324 561 168 699 _15 docx 11 272 8 1 This device integrates analog camera into the ABB Welcome door entry system Up to 4 analog cameras can be connected to 1 camera interface Each external camera is powered independently Pos 10 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Übe rsch rifte n Fü r alle Doku men te 1 E bene U Z U...

Page 4: ...ectric devices and their components via an authorized recycling facilities or disposal companies ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EG WEEE and 2002 95 EG RoHS EU REACH ordinance and law for the implementation of the ordinance EG No 1907 2006 ...

Page 5: ...trol buttons No Functions 1 Bus in 2 Bus out 3 CVBS out 4 Switch on camera power supply For details please see Chapter 4 4 With Without permanent power supply 5 Working mode There are 4 modes for the camera interface For details please see Chapter 4 3 Operation mode 6 Set the address of the associated devices 7 Set the address of the camera interface 8 Operating status notification LED Green ready...

Page 6: ...dent outdoor station Fig 2 Mode 1 works as an independent outdoor station Rotary Value Note Mode 1 Camera interface works as an independent camera interface Addr null ID 2 ID starts from 1 to 9 sequentially and should not be the same address of camera interface or other camera interface Pos 74 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry Bedie nun g M aste r Slave Sc halte r setz en 832 20...

Page 7: ...9 and should be unique Dip Switch 1 4 Turn to ON when a camera is connected Capacity Each camera interface supports 4 analog cameras A total of 15 cameras can be associated with each outdoor station including 2 built in cameras in outdoor station Operation Press to view the cameras individually during surveillance Pos 74 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry Bedie nun g M aste r Sla...

Page 8: ...tch 1 4 Turn to ON when a camera is connected Capacity Each camera interface supports 4 analog cameras A total of 15 cameras can be associated with each guard unit Operation During communication image can be sent from guard unit to indoor station by pressing the Enable button Pos 75 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e Dok ume ntati on Für...

Page 9: ... also be associated with video indoor station If camera interface is associated with video indoor station ID should start from 1 to 9 sequently For details see Chapter 4 3 Programming mode ID null Dip Switch 1 4 Turn to ON when a camera is connected Capacity Each camera interface supports 4 analog cameras Each camera can be associated with different devices i e outdoor station guard unit video ind...

Page 10: ...with outdoor station Mode 3 Camera interface works associated with guard unit Mode 4 Camera interface works associated with indoor station 3 Assign the address of the camera interface by R3 5 Short press Prog button to save current setting 6 Set the address of the associated device by these three rotary switches R1 R2 R3 Address R1 100 R2 10 R3 continue to program 8 Long press Prog button 3s to ex...

Page 11: ...ABB Welcome 11 4 4 With and without permanent power supply 12V 12V Camera with permanent power supply Camera without permanent power supply ...

Page 12: ... 4 5 Video signal from third party DVR Fig 6 Video signal from third party DVR Note 1 DVR output can be one of the inputs for camera interface in modes 1 2 3 and 4 2 Each camera Interface supports 4 DVR singnals DVR ...

Page 13: ...S output to DRV TV there are two options for sending video to DVR Camera interface mode 2 video outdoor station calls video indoor station Camera interface mode 3 Enable button is pressed at guard unit 4 Camera interface doesn t send video to DVR TV during video Indoor station surveillance Pos 75 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e Dok um...

Page 14: ...ingle wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Fine wire clamps 2 x 0 28 mm2 2 x 0 75 mm2 Bus voltage 20 30 V DC Protection IP 30 Operating temperature 25 55 Video input 1Vp p PAL NTSC Video output 1Vp p 75Ω PAL NTSC Camera interface to camera Coax cable Max 100 metres other cables 10 50 metres Size 77 mm x 61 mm x 25 mm 5 2 Device connection diagram Pos 78 B usch J aeg er Neus truk tur M odul Strukt...

Page 15: ...usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Siche rheit Fü r alle D oku ment e War nhinweis e Siche rheit Fachk enn tnisse 18 mo d_1 302 774 384 017_ 15 docx 10 356 4 2 1 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life ...

Page 16: ...on system device Do not install the system controller directly next to the bell transformer and other power supplies to avoid interference Do not install the wires of the system bus together with 100 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a fou...

Page 17: ... 220 AP xxx 19 mod _132 325 040 684 8_1 5 doc x 1 110 98 1 6 3 1 Surface mounted installation 6 3 2 Flush mounted installation 6 3 3 DIN installation Pos 83 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e Dok ume ntati on Für alle Dok ume nte S eiten umb ruch 9 m od_ 126 8898 668 093 _0 docx 521 49 1 ...

Page 18: ... rke Ba ckcove r We reserve the right to at any time make technical changes or changes in the content of this document without prior notice The detailed specifications agreed to at the time of ordering applies to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein T...

Reviews: